Refine Your Search

Search Results

Technical Paper

Real Time Measurements of Diesel Particle Size Distribution with an Electrical Low Pressure Impactor

1998-02-23
980410
Number concentration of particles emitted by combustion engines has recently attracted attention, due to the fact that particles of the size range found in tail pipe emissions are suspected of being hazardous to human health. This paper describes the application of an Electrical Low Pressure Impactor (ELPI) to the measurement of number concentrations of diesel exhaust particles. The size distribution of particles as fine as 30 nm is determined using the aerodynamic diameter as the characteristic dimension. Results were obtained on both the engine and chassis dynamometer, in real-time, for steady state and transient tests. Swedish Environmental Class 1 diesel fuel was used, having a sulfur content of less than 10 ppm wt. A scheme for the calculation of particle losses in the sampling system was developed, showing high penetration of particles under the conditions examined.