Technical Paper

Morphing an Existing Open Source Human Body Model into a Personalized Model for Seating Discomfort Investigation

2020-04-14
2020-01-0874
Computational finite element (FE) human body models (HBM) are used to estimate internal loads and soft tissue deformation, which cannot be easily measured experimentally, for seating discomfort investigation. However, most existing models only represent a limited number of body sizes and postures and cannot be easily personalized and repositioned, which limits their applicability. In recent years, an open source software package has been developed within the European project PIPER (available at www.PIPER-project.org) to help personalize and to position an HBM used for crash injury simulation. In addition to the personalizing and positioning tools, a child model has also been developed and is also now available. The present study aims to derive an adult male HBM to study seating discomfort from the PIPER Child model using the PIPER personalizing tools and information with external body shape and partial internal skeleton of an adult as targets.
Technical Paper

Lower Limb: Advanced FE Model and New Experimental Data

2001-11-01
2001-22-0022
The Lower Limb Model for Safety (LLMS) is a finite element model of the lower limb developed mainly for safety applications. It is based on a detailed description of the lower limb anatomy derived from CT and MRI scans collected on a subject close to a 50th percentile male. The main anatomical structures from ankle to hip (excluding the hip) were all modeled with deformable elements. The modeling of the foot and ankle region was based on a previous model Beillas et al. (1999) that has been modified. The global validation of the LLMS focused on the response of the isolated lower leg to axial loading, the response of the isolated knee to frontal and lateral impact, and the interaction of the whole model with a Hybrid III model in a sled environment, for a total of nine different set-ups. In order to better characterize the axial behavior of the lower leg, experiments conducted on cadaveric tibia and foot were reanalyzed and experimental corridors were proposed.
Technical Paper

Statistical Modeling of Human Liver Incorporating the Variations in Shape, Size, and Material Properties

2013-11-11
2013-22-0012
The liver is one of the most frequently injured abdominal organs during motor vehicle crashes. Realistic numerical assessments of liver injury risk for the entire occupant population require incorporating inter-subject variations into numerical models. The main objective of this study was to quantify the shape variations of human liver in a seated posture and the statistical distributions of its material properties. Statistical shape analysis was applied to construct shape models of the livers of 15 adult human subjects, recorded in a typical seated (occupant) posture. The principal component analysis was then utilized to obtain the modes of variation, the mean model, and 95% statistical boundary shape models. In addition, a total of 52 tensile tests were performed on the parenchyma of three fresh human livers at four loading rates (0.01, 0.1, 1, and 10 s−1) to characterize the rate-dependent and failure properties of the human liver.
Technical Paper

Foot and Ankle Finite Element Modeling Using Ct-Scan Data

1999-10-10
99SC11
Although not life threatening in most cases, victims of lower extremity injuries frequently end up living with a poor quality of life. The implementations of airbag supplement restraint systems significantly reduce the incidence of head and chest injuries. However, the frequency of leg injuries remains high. Several finite element models of the foot and ankle have been developed to further the understanding of this injury mechanism. None of those models employed accurate geometry among various bony segments. The objective of this study is to develop a foot and ankle finite element model based on CT scan data so that joint geometry can be accurately represented. The model was validated against experimental data for several different configurations including typical car crash situations.
Technical Paper

The Effects of Posture and Subject-to-Subject Variations on the Position, Shape and Volume of Abdominal and Thoracic Organs

2009-11-02
2009-22-0005
In this study, the thorax and the abdomen of nine subjects were imaged in four postures using a positional MRI scanner. The four postures were seated, standing, forward-flexed and supine. They were selected to represent car occupants, pedestrians, cyclists and a typical position for medical imaging, respectively. Geometrical models of key anatomical structures were registered from the imaging dataset using a custom registration toolbox. The analysis of the images and models allowed the quantification of the respective effects of posture and subject-to-subject variation on the position, shape and volume of the abdominal organs, skeletal components and thoracic cavity. In summary, except for the supine posture, the organ volumes and their positions in the spinal frame were mostly unaffected by the posture.
Technical Paper

Effect of Abdominal Loading Location on Liver Motion: Experimental Assessment using Ultrafast Ultrasound Imaging and Simulation with a Human Body Model

2016-11-07
2016-22-0003
A protocol based on ultrafast ultrasound imaging was applied to study the in situ motion of the liver while the abdomen was subjected to compressive loading at 3 m/s by a hemispherical impactor or a seatbelt. The loading was applied to various locations between the lower abdomen and the mid thorax while feature points inside the liver were followed on the ultrasound movie (2000 frames per second). Based on tests performed on five post mortem human surrogates (including four tested in the current study), trends were found between the loading location and feature point trajectory parameters such as the initial angle of motion or the peak displacement in the direction of impact. The impactor tests were then simulated using the GHBMC M50 human body model that was globally scaled to the dimensions of each surrogate. Some of the experimental trends observed could be reproduced in the simulations (e.g. initial angle) while others differed more widely (e.g. final caudal motion).
Technical Paper

Comparison of Kriging and Moving Least Square Methods to Change the Geometry of Human Body Models

2015-11-09
2015-22-0013
Finite Element Human Body Models (HBM) have become powerful tools to study the response to impact. However, they are typically only developed for a limited number of sizes and ages. Various approaches driven by control points have been reported in the literature for the non-linear scaling of these HBM into models with different geometrical characteristics. The purpose of this study is to compare the performances of commonly used control points based interpolation methods in different usage scenarios. Performance metrics include the respect of target, the mesh quality and the runability. For this study, the Kriging and Moving Least square interpolation approaches were compared in three test cases. The first two cases correspond to changes of anthropometric dimensions of (1) a child model (from 6 to 1.5 years old) and (2) the GHBMC M50 model (Global Human Body Models Consortium, from 50th to 5th percentile female).
Technical Paper

The Influence of Surrogate Blood Vessels on the Impact Response of a Physical Model of the Brain

2004-11-01
2004-22-0012
Cerebral blood vessels are an integral part of the brain and may play a role in the response of the brain to impact. The purpose of this study was to quantify the effects of surrogate vessels on the deformation patterns of a physical model of the brain under various impact conditions. Silicone gel and tubing were used as surrogates for brain tissue and blood vessels, respectively. Two aluminum cylinders representing a coronal section of the brain were constructed. One cylinder was filled with silicone gel only, and the other was filled with silicone gel and silicone tubing arranged in the radial direction in the peripheral region. An array of markers was embedded in the gel in both cylinders to facilitate strain calculation via high-speed video analysis. Both cylinders were simultaneously subjected to a combination of linear and angular acceleration using a two-segment pendulum.
Journal Article

Ligaments Laxity and Elongation at Injury in Flexed knees during Lateral Impact Conditions

2023-06-27
2022-22-0003
The knee is one of the regions of interest for pedestrian safety assessment. Past testing to study knee ligament injuries for pedestrian impact only included knees in full extension and mostly focused on global responses. As the knee flexion angle and the initial ligament laxity may affect the elongation at which ligaments fail, the objectives of this study were (1) to design an experimental protocol to assess the laxity of knee ligaments before measuring their elongation at failure, (2) to apply it in paired knee tests at two flexion angles (10 and 45 degrees). The laxity tests combined strain gauges to measure bone strains near insertions that would result from ligament forces and a custom machine to exercise the knee in all directions. Failure was assessed using a four-point bending setup with additional degrees of freedom on the axial rotation and displacement of the femur. A template was designed to ensure that the two setups used the exact same starting position.