Technical Paper

Biomechanical Analysis of Knee Impact in Frontal Collisions through Finite Element Simulations with a Full Human Body Model

2008-06-17
2008-01-1887
This study applies a detailed finite element model of the human body to simulate occupant knee impacts experienced in vehicular frontal crashes. The human body model includes detailed anatomical features of the head, neck, chest, thoracic and lumbar spine, abdomen, and lower and upper extremities. The material properties used in the model for each anatomic part of the human body were obtained from test data reported in the literature. The total human body model used in the current study has been previously validated in frontal and side impacts. Several cadaver knee impact tests representing occupants in a frontal impact condition were simulated using the previously validated human body model. Model impact responses in terms of force-time and acceleration-time histories were compared with test results. In addition, stress distributions of the patella, femur, and pelvis were reported for the simulated test conditions.
Technical Paper

Head Injury Potential Assessment in Frontal Impacts by Mathematical Modeling

1994-11-01
942212
The potential of head injury in frontal barrier impact tests was investigated by a mathematical model which consisted of a finite element human head model, a four segments rigid dynamic neck model, a rigid body occupant model, and a lumped-mass vehicle structure model. The finite element human head model represents anatomically an average adult head. The rigid body occupant model simulates an average adult male. The structure model simulates the interior space and the dynamic characteristics of a vehicle. The neck model integrates the finite element human head to the occupant body to give a more realistic kinematic head motion in a barrier crash test. Model responses were compared with experimental cadaveric data and vehicle crash data for the purpose of model validation to ensure model accuracy. Model results show a good agreement with those of the tests.
Technical Paper

A Biomechanical Analysis of Head, Neck, and Torso Injuries to Child Surrogates Due to Sudden Torso Acceleration

1984-10-01
841656
This paper reports on the injuries to the head, neck and thorax of fifteen child surrogates, subjected to varying levels of sudden acceleration. Measured response data in the child surrogate tests and in matched tests with a three-year-old child test dummy are compared to the observed child surrogates injury levels to develop preliminary tolerance data for the child surrogate. The data are compared with already published data in the literature.
Technical Paper

The Position of the United States Delegation to the ISO Working Group 6 on the Use of HIC in the Automotive Environment

1985-06-01
851246
A review and analysis of existing cadaver head impact data has been conducted in this paper. The association of the Head Injury Criterion with experimental cadaver skull fracture and brain damage has been investigated, and risk curves of HIC versus skull fracture and brain damage have been developed. Limitation of the search for the maximum HIC duration to 15ms has been recommended for the proper use of HIC in the automotive crash environment.
Technical Paper

The Effects of Skull Thickness Variations on Human Head Dynamic Impact Responses

2001-11-01
2001-22-0018
Variations in human skull thickness affecting human head dynamic impact responses were studied by finite element modeling techniques, experimental measurements, and histology examinations. The aims of the study were to better understand the influences of skull thickness variations on human head dynamic impact responses and the injury mechanisms of human head during direct impact. The thicknesses of the frontal bone of seven human cadaver skulls were measured using ultrasonic technology. These measurements were compared with previous experimental data. Histology of the skull was recorded and examined. The measured data were analyzed and then served as a reference to vary the skull thickness of a previously published three-dimensional finite element human head model to create four models with different skull thickness. The skull thicknesses modeled are 4.6 mm, 5.98 mm, 7.68 mm, and 9.61 mm.
Technical Paper

Development of a Subhuman Primate Brain Finite Element Model to Investigate Brain Injury Thresholds Induced by Head Rotation

2020-03-31
2019-22-0003
An anatomically detailed rhesus monkey brain FE model was developed to simulate in vivo responses of the brain of sub-human primates subjected to rotational accelerations resulting in diffuse axonal injury (DAI). The material properties used in the monkey model are those in the GHBMC 50th percentile male head model (Global Human Body Model Consortium). The angular loading simulations consisted of coronal, oblique and sagittal plane rotations with the center of rotation in neck to duplicate experimental conditions. Maximum principal strain (MPS) and Cumulative strain damage measure (CSDM) were analyzed for various white matter structures such as the cerebrum subcortical white matter, corpus callosum and brainstem.
Technical Paper

Finite Element Model Development of Sid-Iis

1999-10-10
99SC06
This paper describes the development and validation of a finite element model of the SID-IIs beta+-prototype dummy using a nonlinear explicit finite element code. The geometry of the SID-IIs dummy is modeled with shell and solid elements from digital scans. The material properties are derived from dynamic tests and the model validation is conducted on component, subassembly and full assembly levels. Component level validation of the head/neck, arm, ribs, and lumbar spine is presented. The model validation of the thorax and pelvis subassemblies as well as pendulum calibration tests (shoulder, thorax, abdomen, and pelvis) and rigid-wall sled tests of the fully assembled dummy mode is also presented. The model response compares favorably with experimental data and provides a reasonable level of confidence in the model biofidelity.
Technical Paper

Interactions of Out-of-Position Small-Female Surrogates with a Depowered Driver Airbag

2008-11-03
2008-22-0008
The objectives of this study were to examine the response, repeatability, and injury predictive ability of the Hybrid III small-female dummy to static out-of-position (OOP) deployments using a depowered driver-side airbag. Five dummy tests were conducted in two OOP configurations by two different laboratories. The OOP configurations were nose-on-rim (NOR) and chest-on-bag (COB). Four cadaver tests were conducted using unembalmed small-female cadavers and the same airbags used in the dummy tests under similar OOP conditions. One cadaver test was designed to increase airbag loading of the face and neck (a forehead-on-rim, or FOR test). Comparison between the dummy tests of Lab 1 and of Lab 2 indicated the test conditions and results were repeatable. In the cadaver tests no skull fractures or neck injuries occurred. However, all four cadavers had multiple rib fractures.
Technical Paper

Impact Response and Biomechanical Analysis of the Knee-Thigh-Hip Complex in Frontal Impacts with a Full Human Body Finite Element Model

2008-11-03
2008-22-0019
Changes in vehicle safety design technology and the increasing use of seat-belts and airbag restraint systems have gradually changed the relative proportion of lower extremity injuries. These changes in real world injuries have renewed interest and the need of further investigation into occupant injury mechanisms and biomechanical impact responses of the knee-thigh-hip complex during frontal impacts. This study uses a detailed finite element model of the human body to simulate occupant knee impacts experienced in frontal crashes. The human body model includes detailed anatomical features of the head, neck, shoulder, chest, thoracic and lumbar spine, abdomen, pelvis, and lower and upper extremities. The material properties used in the model for each anatomic part of the human body were obtained from test data reported in the literature. The human body model used in the current study has been previously validated in frontal and side impacts.
Technical Paper

Prediction and Analysis of Human Thoracic Impact Responses and Injuries in Cadaver Impacts Using a Full Human Body Finite Element Model

2003-10-27
2003-22-0014
Human thoracic dynamic responses and injuries associated with frontal impact, side impact, and belt loading were investigated and predicted using a complete human body finite element model for an average adult male. The human body model was developed to study the impact biomechanics of a vehicular occupant. Its geometry was based on the Visible Human Project (National Library of Medicine) and the topographies from human body anatomical texts. The data was then scaled to an average adult male according to available biomechanical data from the literature. The model includes details of the head, neck, ribcage, abdomen, thoracic and lumbar spine, internal organs of the chest and abdomen, pelvis, and the upper and lower extremities. The present study is focused on the dynamic response and injuries of the thorax.
Technical Paper

Effect of Head-Neck Position on Cervical Facet Stretch of Post Mortem Human Subjects during Low Speed Rear End Impacts

2004-11-01
2004-22-0015
The purpose of this study was to determine the effect of head-neck position on cervical facet stretch during low speed rear end impact. Twelve tests were conducted on four Post Mortem Human Subjects (PMHS) in a generic bucket seat environment. Three head positions, namely Normal (neutral), Zero Clearance between the head and head restraint, and Body Forward positions were tested. A high-speed x-ray system was used to record the motion of cervical vertebrae during these tests. Results demonstrate that: a) The maximum mean facet stretch at head restraint contact occurs at MS4 and MS5 for the Body Forward condition, b) The lower neck flexion moment, prior to head contact, shows a non-linear relationship with facet stretch, and c) “Differential rebound” during rear end impact increases facet stretch.