Refine Your Search

Topic

Author

Affiliation

Search Results

Technical Paper

Comparison of PMHS, WorldSID, and THOR-NT Responses in Simulated Far Side Impact

2007-10-29
2012-01-1537
Injury to the far side occupant has been demonstrated as a significant portion of the total trauma in side impacts. The objective of the study was to determine the response of PMHS in far side impact configurations, with and without generic countermeasures, and compare responses to the WorldSID and THOR dummies. A far side impact buck was designed for a sled test system that included a center console and three-point belt system. The buck allowed for additional options of generic countermeasures including shoulder or thorax plates or an inboard shoulder belt. The entire buck could be mounted on the sled in either a 90-degree (3-o'clock PDOF) or a 60-degree (2-o'clock PDOF) orientation. A total of 18 tests on six PMHS were done to characterize the far side impact environment at both low (11 km/h) and high (30 km/h) velocities. WorldSID and THOR-NT tests were completed in the same configurations to conduct matched-pair comparisons.
Journal Article

Development of Injury Probability Functions for the Flexible Pedestrian Legform Impactor

2012-04-16
2012-01-0277
The goal of this study was to develop injury probability functions for the leg bending moment and MCL (Medial Collateral Ligament) elongation of the Flexible Pedestrian Legform Impactor (Flex-PLI) based on human response data available from the literature. Data for the leg bending moment at fracture in dynamic 3-point bending were geometrically scaled to an average male using the standard lengths obtained from the anthropometric study, based on which the dimensions of the Flex-PLI were determined. Both male and female data were included since there was no statistically significant difference in bone material property. Since the data included both right censored and uncensored data, the Weibull Survival Model was used to develop a human leg fracture probability function.
Technical Paper

Internal vs. External Chest Deformation Response to Shoulder Belt Loading, Part 1: Table-Top Tests

2009-04-20
2009-01-0393
This study presents a detailed comparison of internally and externally measured chest deflections resulting from eight tests conducted on three male post mortem human subjects. A hydraulically driven shoulder belt loaded the anterior thorax under a fixed spine condition while displacement data were obtained via a high-speed 16-camera motion capture system (VICON MX™). Comparison of belt displacement and sternal displacement measured at the bone surface provided a method for quantifying effective change in superficial soft tissue depth at the mid sternum under belt loading. The relationship between the external displacement and the decrease in the effective superficial tissue depth was found to be monotonic and nonlinear. At 65 mm of mid-sternal posterior displacement measured externally, the effective thickness of the superficial tissues and air gap between the belt and the skin had decreased by 14 mm relative to the unloaded state.
Technical Paper

Development and Validation of a Finite Element Model of a Vehicle Occupant

2004-03-08
2004-01-0325
A finite element human model has been developed to simulate occupant behavior and to estimate injuries in real-world car crashes. The model represents an average adult male of the US population in a driving posture. Physical geometry, mechanical characteristics and joint structures were replicated as precise as possible. The total number of nodes and materials is around 67,000 and 1,000 respectively. Each part of the model was not only validated against human test data in the literature but also for realistic loading conditions. Additional tests were newly conducted to reproduce realistic loading to human subjects. A data set obtained in human volunteer tests was used for validating the neck part. The head-neck kinematics and responses in low-speed rear impacts were compared between the measured and calculated results. The validity of the lower extremity part was examined by comparing the tibia force in a foot impact between the test data and simulation results.
Technical Paper

A Normalization Technique for Developing Corridors from Individual Subject Responses

2004-03-08
2004-01-0288
This paper presents a technique for developing corridors from individual subject responses contained in experimental biomechanical data sets. Force-deflection response is used as an illustrative example. The technique begins with a method for averaging human subject force-deflection responses in which curve shape characteristics are maintained and discontinuities are avoided. Individual responses sharing a common characteristic shape are averaged based upon normalized deflection values. The normalized average response is then scaled to represent the given data set using the mean peak deflection value associated with the set of experimental data. Finally, a procedure for developing a corridor around the scaled normalized average response is presented using standard deviation calculations for both force and deflection.
Technical Paper

Sled System Requirements for the Analysis of Side Impact Thoracic Injury Criteria and Occupant Protection

2001-03-05
2001-01-0721
This paper discusses struck-side occupant thoracic response to side-impact loading and the requirements of a sled system capable of reproducing the relevant motions of a laterally impacted vehicle. A simplified viscoelastic representation of a thorax is used to evaluate the effect of the door velocity-time profile on injury criteria and on the internal stress state of the thorax. Simulations using a prescribed door velocity-time profile (punch impact) are contrasted against simulations using a constant-velocity impact (Heidelberg-type impact). It is found that the stress distribution and magnitude within the thorax, in addition to the maximum thorax compression and viscous response, depend not only on the door-occupant closing velocity, but also on the shape of the door velocity-time profile throughout the time of contact with the occupant. A sled system capable of properly reproducing side-impact door and seat motion is described.
Technical Paper

Displacement Measurements in the Hybrid III Chest

2001-03-05
2001-01-0118
This paper presents an analysis of the displacement measurement of the Hybrid III 50th percentile male dummy chest in quasistatic and dynamic loading environments. In this dummy, the sternal chest deformation is typically characterized using a sliding chest potentiometer, originally designed to measure inward deflection in the central axis of the dummy chest. Loading environments that include other modes of deformation, such as lateral translations or rotations, can create a displacement vector that is not aligned with this sensitive axis. To demonstrate this, the dummy chest was loaded quasistatically and dynamically in a series of tests. A string potentiometer array, with the capability to monitor additional deflection modes, was used to supplement the measurement of the chest slider.
Technical Paper

Parametric study of side impact thoracic injury criteria using the MADYMO human body model

2001-06-04
2001-06-0182
This paper presents a computational study of the effects of three parameters on the resulting thoracic injury criteria in side impacts. The parameters evaluated are a) door velocity-time (V-t) profile, b) door interior padding modulus, and c) initial door-to-occupant offset. Regardless of pad modulus, initial offset, or the criterion used to assess injury, higher peak door velocity is shown to correspond with more severe injury. Injury outcome is not, however, found to be sensitive to the door velocity at the time of first occupant contact. A larger initial offset generally is found to result in lower injury, even when the larger offset results in a higher door velocity at occupant contact, because the increased offset results in contact later in the door V-t profile - closer to the point at which the door velocity begins to decrease. Cases of contradictory injury criteria trends are identified, particularly in response to changes in the pad modulus.
Technical Paper

Dynamic response analysis of the THOR-LX dummy lower extremity

2001-06-04
2001-06-0072
Regarding THOR-50AM dummy lower extremities (hereafter referred to as ""THOR''and ""THOR-LX'') developed as an assembly of lower extremities for next-generation dummies in frontal impact test, we have conducted a series of tests as follows. HYGE sled tests with a toe-board simulating the impact upon intrusion into the vehicle compartment around the occupant feet, dummy dropping tests with two different postures; one is the upright posture with the knees set straight and another is the posture with the knees bent, in order to apply impact loads and to measure/evaluate the impact response characteristics.
Technical Paper

Differences in the Dynamic Responses of the Thor-NT and Thor-FT Dummies

2006-04-03
2006-01-0676
The structural differences between the Thor-NT and Thor-FT dummies, which have been proposed as next-generation dummies for frontal crash tests, were examined and the differences in dynamic response were verified by testing. Tests were performed on a HYGE sled simulating a frontal crash at an impact speed of 56 km/h. The 3-point seatbelt plus air bag combination was adopted as the restraint mechanism. Differences in characteristics of the two dummies in the neck, thorax, and abdomen were found by calibration tests. Test results showed that the variation in shape of the abdominal area of the pelvis generates some disparity in the flexion of the thorax and abdomen.
Technical Paper

Comparison of Belted Hybrid III, THOR, and Cadaver Thoracic Responses in Oblique Frontal and Full Frontal Sled Tests

2003-03-03
2003-01-0160
This paper compares restrained Hybrid III and THOR thoracic kinematics and cadaver injury outcome in 30° oblique frontal and in full frontal sled tests. Peak shoulder belt tension, the primary source of chest loading, changed by less than four percent and peak chest resultant acceleration changed by less than 10% over the 30° range tested. Thoracic kinematics were likewise insensitive to the direction of the collision vector, though they were markedly different between the two dummies. Mid-sternal Hybrid III chest deflection, measured by the standard sternal potentiometer and by supplemental internal string potentiometers, was slightly lower (∼10%) in the oblique tests, but the oblique tests produced a negligible increase in lateral movement of the sternum. In an attempt to understand the biofidelity of these dummy responses, a series of 30-km/h human cadaver tests having several collision vectors (0°, 15°, 30°, 45°) was analyzed.
Technical Paper

Development of an Abdominal Deformation Measuring System for Hybrid III Dummy

1994-11-01
942223
A new abdominal deformation measuring system for Hybrid III dummy has been developed in order to evaluate the abdominal injury by using the dummy. From the dynamic abdominal deformation of the dummy, the abdominal compression velocity V, the compression ratio C, and the maximum value of the product VC, expressed as [VC]MAX, can be calculated. This abdominal deformation measuring system consists of an abdominal insert having the same compression characteristics as those of the human body, a dynamic deformation sensor, and an analysis program. The abdominal insert is made of elastic foam rubber and has a shape fitted to Hybrid III. The deformation sensor in a band shape is a thin stainless steel band with 25 strain gauges on it. Each strain gauge measures the curvature on its mounted position. Since the deformation sensor is located along the surface of the dummy abdomen, the sensor deforms as the dummy surface deforms.
Technical Paper

Evaluations of the Recommended New Parts for the Hybrid III Dummy - Neck Shield and Hip Joint

1996-02-01
960450
Three improvements for the Hybrid III dummy parts are proposed by NHTSA, they are the neck shield, hip joint, and ankle joint In this paper, two modifications of the three, the neck shield and hip joint, are evaluated The recommended neck shield was tested and compared to the previous type to investigate the following, 1 The effect of the neck moment on both the recommended and previous type, and 2 The comparison between the stiffness of the neck shield and human soft tissue under the chin, using a volunteer static test From these tests, the new recommended neck shield performed better than the previous type with respect to both biofidelity and the effect on the neck moment test The neck shield for 5th-percentile female was also considered The hip joint recommended by NHTSA was compared with the modified joint and pelvis proposed by Toyota It was found that the NHTSA's recommended hip joint eliminated the hip lock due to metal-to-metal contact It was also found that the maximum rotation angle of the NHTSA's recommended hip joint was less than that of the hip joint and pelvis proposed by Toyota
Technical Paper

Saving Lives with V2X versus On-Board Sensing Systems -Which will be More Effective?: Technology Leadership Brief

2012-10-08
2012-01-9017
Infrastructure systems such as vehicle-to-vehicle (V2V) and vehicle-to-infrastructure (V2X) communication can theoretically prevent nearly all accidents by gathering the speed, locations, and travel directions of traffic participants, and intervening to control vehicle motion as required to help prevent collisions. However, during the phase-in of the communication systems, there will be many vehicles and many roads that do not have the communication systems in place, and therefore the system will not be effective in those cases. This lack of availability is likely the main disadvantage. On-board sensing (autonomous) systems such as cameras and radar sensors may not detect all potential hazards (e.g. due to weather, or hidden hazards), but they are effective in many situations and can help prevent crashes without depending on communication with infrastructure or other vehicles.
Technical Paper

Elimination of Thoracic Muscle Tensing Effects for Frontal Crash Dummies

2005-04-11
2005-01-0307
Current crash dummy biofidelity standards include the estimated effects of tensing the muscles of the thorax. This study reviewed the decision to incorporate muscle tensing by examining relevant past studies and by using an existing mathematical model of thoracic impacts. The study finds evidence that muscle tensing effects are less pronounced than implied by the biofidelity standard response corridors, that the response corridors were improperly modified to include tensing effects, and that tensing of other body regions, such as extremity bracing, may have a much greater effect on the response and injury potential than tensing of only the thoracic musculature. Based on these findings, it is recommended that muscle tensing should be eliminated from thoracic biofidelity requirements until there is sufficient information regarding multi-region muscle tensing response and the capability to incorporate this new data into a crash dummy.
Technical Paper

A Method for the Experimental Investigation of Acceleration as a Mechanism of Aortic Injury

2005-04-11
2005-01-0295
Rupture of the thoracic aorta is a leading cause of rapid fatality in automobile crashes, but the mechanism of this injury remains unknown. One commonly postulated mechanism is a differential motion of the aortic arch relative to the heart and its neighboring vessels caused by high-magnitude acceleration of the thorax. Recent Indy car crash data show, however, that humans can withstand accelerations exceeding 100 g with no injury to the thoracic vasculature. This paper presents a method to investigate the efficacy of acceleration as an aortic injury mechanism using high-acceleration, low chest deflection sled tests. The repeatability and predictability of the test method was evaluated using two Hybrid III tests and two tests with cadaver subjects. The cadaver tests resulted in sustained mid-spine accelerations of up to 80 g for 20 ms with peak mid-spine accelerations of up to 175 g, and maximum chest deflections lower than 11% of the total chest depth.
Technical Paper

A Comparison Study of Car-to-Pedestrian and Car-to-E-Bike Accidents: Data Source: The China In-Depth Accident Study (CIDAS)

2014-04-01
2014-01-0519
The aim of the study was to investigate the difference between car-to-e-bikes and car-to-pedestrian accidents. The China In-depth Accident Study (CIDAS) database was searched from 2011 to 2013 for pedestrians and e-bikes struck by car, van and SUV fronts, which resulted in 104 pedestrian and 85 e-bike cases where information was sufficient for in-depth analysis. Reconstruction by PC-Crash was performed for all of the sampled cases. Pre-crash parameters were calculated by a MATLAB code. Focus was on prototypical accident scenarios and causes; speed as well as possible prevention countermeasures. It has been shown that traffic light violations, road priority violations, and unsure safety (these situations included misjudgments, unpreparedness, proximity to other road users, inappropriate speeds, etc.…) are the main causes in both the VRU groups. Distinctions were found for aspects of car collision speed, accident scenario, distribution of head contact points and so on.
Technical Paper

ASSESSING THE INFLUENCE OF CRASH PULSE, SEAT FORCE CHARACTERISTICS, AND HEAD RESTRAINT POSITION ON NICmax IN REAR-END CRASHES USING A MATHEMATICAL BioRID DUMMY

1999-09-23
1999-13-0015
The major car and crash related risk factors for Whiplash Associated Disorders (WAD) 1-3 long-term neck injuries in rear-end crashes are the shape of the crash pulse, the seat-force characteristics and the head restraint position. However, the specific roles of these factors are not yet fully understood, which makes it difficult to find adequate countermeasures and to design protective car seats. In order to study these issues, a mathematical MADYMO model of the first version of the Biofidelic Rear Impact Dummy (BioRID I) has previously been developed. In addition, a neck injury criterion, NICmax, has been proposed and evaluated by means of dummy, human and rear-end impact simulations. In this paper the MADYMO BioRID I and four car seats ranked differently according to a disability ranking list are used to study the influence of crash pulse, seat-force characteristics, and head restraint position on the NICmax in rear-end crashes.
Technical Paper

Thoracic Response to Dynamic, Non-Impact Loading from a Hub, Distributed Belt, Diagonal Belt, and Double Diagonal Belts

2004-11-01
2004-22-0022
This paper presents thoracic response corridors developed using fifteen post-mortem human subjects (PMHS) subjected to single and double diagonal belt, distributed, and hub loading on the anterior thorax. We believe this is the first study to quantify the force-deflection response of the same thorax to different loading conditions using dynamic, non-impact, restraint-like loading. Subjects were positioned supine on a table and a hydraulic master-slave cylinder arrangement was used with a high-speed materials testing machine to provide controlled chest deflection at a rate similar to that experienced by restrained PMHS in a 48-km/h sled test. All loading conditions were tested at a nominally non-injurious level initially. When the battery of non-injurious tests was completed, a single loading condition was used for a final, injurious test (nominal 40% chest deflection).
Technical Paper

Impact Response of Restrained PMHS in Frontal Sled Tests: Skeletal Deformation Patterns Under Seat Belt Loading

2009-11-02
2009-22-0001
This study evaluated the response of restrained post-mortem human subjects (PMHS) in 40 km/h frontal sled tests. Eight male PMHS were restrained on a rigid planar seat by a custom 3-point shoulder and lap belt. A video motion tracking system measured three-dimensional trajectories of multiple skeletal sites on the torso allowing quantification of ribcage deformation. Anterior and superior displacement of the lower ribcage may have contributed to sternal fractures occurring early in the event, at displacement levels below those typically considered injurious, suggesting that fracture risk is not fully described by traditional definitions of chest deformation. The methodology presented here produced novel kinematic data that will be useful in developing biofidelic human models.