Refine Your Search

Search Results

Technical Paper

Initial Result of Integrated Testing of a Regenerative ECLSS at MSFC

1987-07-01
871454
General plans for testing of a regenerative ECLS system in a Module Simulator at MSFC have been been discussed in a previous paper; preliminary test results are given in this paper and a companion by Mr. McAlister. Subsystems for this series of tests have been provided by Life Systems, Inc., AiResearch Manufacturing Co., Umpqua Research Company, Lockheed, and Hamilton Standard. Results of testing those subsystems provided by Hamilton Standard are covered in the other paper. Subsystems have been installed in the Module Simulator in accordance with the test plan. These include the 4-bed Molecular Sieve, the Static Feed Water Electrolysis Subsystem, and the Urine Pretreatment/Mixing Unit to be covered herein.
X