Refine Your Search

Search Results

Viewing 1 to 8 of 8
Standard

EXTERIOR SOUND LEVEL MEASUREMENT PROCEDURE FOR SELF-PROPELLED AGRICULTURAL FIELD EQUIPMENT

1978-05-01
HISTORICAL
J1008_197805
This SAE Recommended Practice sets forth the instrumentation and procedures to be used in measuring exterior sound levels of self-propelled agricultural field equipment of 15 kW (20 net engine hp) or greater. It is not intended to cover operation of safety devices (such as alarms), or equipment used primarily in stationary operation. The sound levels obtained by using this test procedure are repeatable and representative of the higher range of sound levels generated by the machine in normal road transport. The sound levels are not intended to represent the average or equivalent sound levels over a field use cycle.
Standard

SOUND MEASUREMENT—SELF-PROPELLED AGRICULTURAL EQUIPMENT—EXTERIOR

1987-01-01
HISTORICAL
J1008_198701
This SAE Recommended Practice sets forth the instrumentation and procedures to be used in measuring exterior sound levels of self-propelled agricultural field equipment of 15 kW (20 net engine hp) or greater. It is not intended to cover operation of safety devices (such as alarms), or equipment used primarily in stationary operation. The sound levels obtained by using this test procedure are repeatable and representative of the higher range of sound levels generated by the machine in normal road transport. The sound levels are not intended to represent the average or equivalent sound levels over a field use cycle.
Standard

Sound Power Level Measurements of Work Machines—Static and In-Place Dynamic Methods

2003-01-30
HISTORICAL
J1805_200301
This SAE Standard is used to determine the exterior A-weighted equivalent sound power level of static and in-place dynamic machines (dozer, loader, excavator, and backhoe) similar to the sound power obtained in ISO 6393 static and ISO 6395 dynamic sound power test procedures. Additional machine types, specifically sweepers and scrubbers, covered by SAE J2130 have been added, and other work machine types covered by SAE J1116 may be added with appropriate cycle descriptions and machine preparation. The recommended test procedures include conventional integrating sound pressure level methods or the sound intensity method using paired microphones. The sound intensity methodology provides a practical indoor alternative and permits measurement in the factory environment. The procedures in this document assume that the dominant sources are not highly sensitive to load (i.e., cooling fan, engine, track system).
Standard

SOUND POWER DETERMINATION—EARTHMOVING MACHINERY—STATIC CONDITION

1981-12-01
J1372_198112
The requirements for setting up and operating the machinery, the microphone array and the size of the hemispherical measurement surface are given in this recommended practice. This recommended practice shall be used in conjunction with ISO 4872-1978, which gives the basic criteria for the acoustic environment, instrumentation, microphone positions, procedures for the measurement of the A-weighted sound pressure levels and the calculation of the A-weighted sound power levels.
Standard

SOUND POWER DETERMINATION—EARTHMOVING MACHINERY—STATIC CONDITION

1983-06-01
J1372_198306
The requirements for setting up and operating the machinery, the microphone array and the size of the hemispherical measurement surface are given in this recommended practice. This recommended practice shall be used in conjunction with ISO 4872-1978, which gives the basic criteria for the acoustic environment, instrumentation, micro phone positions, procedures for the measurement of the A-weighted sound pressure levels and the calculation of the A-weighted sound power levels.
Standard

SOUND POWER DETERMINATION—EARTHMOVING MACHINERY—STATIC CONDITION

1988-07-13
J1372_198807
The requirements for setting up and operating the machinery, the microphone array and the size of the hemispherical measurement surface are given in this standard. This standard shall be used in conjunction with ISO 4872-1978, which gives the basic criteria for the acoustic environment, instrumentation, microphone positions, procedures for the measurement of the A-weighted sound pressure levels and the calculation of the A-weighted sound power levels.
Standard

Sound Measurement—Construction Site

2000-06-28
HISTORICAL
J1075_200006
This SAE Standard sets forth measurement procedures and instrumentation to be used for determining a “representative” sound level during a representative time period at selected measurement locations on a construction site boundary. The document is not intended for use in determining occupational hearing damage risk. Determination of a representative time period is left to the judgment of the user.
Standard

SOUND MEASUREMENT - OFF-ROAD SELF-PROPELLED WORK MACHINES OPERATOR-WORK CYCLE

1990-05-01
HISTORICAL
J1166_199005
This SAE Standard sets forth the procedures to be used in measuring sound levels and determining the time weighted sound level at the operator's stations(s) of specified off-road self-propelled work machines. This document applies to the following work machines which have operator stations as specified in SAE J1116: Crawler Loader Wheel Loader Dumper Tractor Scraper Grader Crawler Tractor with Dozer Wheel Tractor with Dozer Pad Foot Wheel Compactor with Dozer Backhoe Hydraulic Excavator Log Skidder Excavator & Wheel Feller-Buncher Pipelayer Roller/Compactor Trencher The Instrumentation requirements and specific work cycles for these machines are described. The method used to calculate the time weighted average sound level at the operator statlon(s) is specified for Leq(5), or optional exchange rates, during continuous operation in a work cycle. A method to relate the time weighted average sound level at the operator statlon(s) to operator sound exposure is also provided.
X