A Simplified Method to Make Temperature Measurements of a Metal Surface using the Surface as One Component of Thermocouple

2008-04-14
2008-01-0918
Instrumentation of an exhaust system to measure surface temperature at multiple locations usually involves welding independent thermocouples to the surface of the system. This report describes a new type of thermocouple fabricated to measure temperature at a point or temperature difference between points on a metallic object utilizing the metal as one component of the new thermocouple. AISI 316 stainless steel is used in the current study to represent automotive exhaust pipe. The other component of the thermocouple is Nickel-Chromium (Chromel, Chromega), one of the two metals used in type K thermocouples, which are generally used for exhaust temperature measurements during emission tests. Use of the new thermocouple is contingent upon an accurate calibration of its response to changes in temperature.