Journal Article

Finite-Element-Based Transfer Equations: Post-Mortem Human Subjects versus Hybrid III Test Dummy in Frontal Sled Impact

2015-04-14
2015-01-1489
Transfer or response equations are important as they provide relationships between the responses of different surrogates under matched, or nearly identical loading conditions. In the present study, transfer equations for different body regions were developed via mathematical modeling. Specifically, validated finite element models of the age-dependent Ford human body models (FHBM) and the mid-sized male Hybrid III (HIII50) were used to generate a set of matched cases (i.e., 192 frontal sled impact cases involving different restraints, impact speeds, severities, and FHBM age). For each impact, two restraint systems were evaluated: a standard three-point belt with and without a single-stage inflator airbag. Regression analyses were subsequently performed on the resulting FHBM- and HIII50-based responses. This approach was used to develop transfer equations for seven body regions: the head, neck, chest, pelvis, femur, tibia, and foot.
Journal Article

Finite-Element-Based Transfer Equations: Post-Mortem Human Subjects versus Hybrid III Test Dummy in Blunt Impact

2014-04-01
2014-01-0486
In the present study, transfer equations relating the responses of post-mortem human subjects (PMHS) to the mid-sized male Hybrid III test dummy (HIII50) under matched, or nearly-identical, loading conditions were developed via math modeling. Specifically, validated finite element (FE) models of the Ford Human Body Model (FHBM) and the HIII50 were used to generate sets of matched cases (i.e., 256 frontal impact cases involving different impact speeds, severities, and PMHS age). Regression analyses were subsequently performed on the resulting age-dependent FHBM- and HIII50-based responses. This approach was conducted for five different body regions: head, neck, chest, femur, and tibia. All of the resulting regression equations, correlation coefficients, and response ratios (PHMS relative to HIII50) were consistent with the limited available test-based results.
Technical Paper

Investigation into the Noise Associated with Airbag Deployment: Part II - Injury Risk Study Using a Mathematical Model of the Human Ear

1998-11-02
983162
Airbag deployments are associated with loud noise of short duration, called impulse noise. Research performed in the late 1960's and early 1970's established several criteria for assessment of the risk of impulse noise-induced hearing loss for military weapons and general exposures. These criteria were modified for airbag noise in the early 1970's, but field accident statistics and experimental results with human volunteers exposed to airbags do not seem to agree with the criteria. More recent research on impulse noise from weapons firing, in particular that of Price & Kalb of the US Army Research Laboratory, has led to development of a mathematical model of the ear. This model incorporates transfer functions which alter the incident sound pressure through various parts of the ear. It also calculates a function, called the “hazard”, that is a measure of mechanical fatigue of the hair cells in the inner ear.
Technical Paper

Laboratory Experience with the IR-TRACC Chest Deflection Transducer

2002-03-04
2002-01-0188
In 1998, Rouhana et al. described development of a new device, called the IR-TRACC (InfraRed - Telescoping Rod for Assessment of Chest Compression). In its original concept, the IR-TRACC uses two infrared LEDs inside of a telescoping rod to measure deflection. One LED serves as a light transmitter and the other as a light receiver. The output from the receiver LED is converted to a linear function of chest compression using an analog circuit. Tests have been performed with IR-TRACC units at various labs around the world since 1998. A first-generation IR-TRACC system was retrofit into a Q3 dummy by TNO. Similarly, a mid sized male Hybrid III dummy thorax and a small female Hybrid III dummy thorax have been designed by First Technology Safety Systems (FTSS) such that each contains 4 second-generation IR-TRACC units. The second-generation IR-TRACC is the result of continued development by FTSS, especially in the areas of the analysis circuit, manufacturing and calibration methods.
Technical Paper

Development of a New Standard for Measurement of Impulse Noise Associated With Automotive Inflatable Devices

2005-05-16
2005-01-2398
The SAE Recommended Practice for measuring impulse noise from airbags, SAE J247, “Instrumentation for Measuring Acoustic Impulses within Vehicles”, was first published in 1971 and last affirmed in 1987. Many advances have occurred in understanding and technology since that time. Work in the automotive industry to investigate the characteristics of noise from airbag deployments has shown that large components of low frequency noise can be present when an airbag deploys in a closed vehicle. Others have shown that this low frequency noise can have a protective effect on the ear. Likewise, work for many years at the US Army Research Lab has investigated the risk of hearing loss for a human subjected to an acoustic impulse. That research led to the creation and validation of a mathematical model of the human ear, called Auditory Hazard Assessment Algorithm - Human (AHAAH).
Technical Paper

Lateral Impact-An Analysis of the Statistics in the NCSS

1985-12-01
851727
Data from the National Crash Severity Study (NCSS) has been analyzed with respect to lateral impacts. Accident variables, vehicle variables, and occupant variables, and their interactions have been considered. Emphasis has been placed on occupant variables, especially occupant injury patterns. This report is mainly a compendium of the data, including a comparison of the NCSS statistics with those from France, Germany, and Great Britain. Overall, these lateral impact statistics are quite similar to results of other field accident studies, which is an interesting observation given the diverse vehicle and driver populations and the differing traffic situations experienced by those populations. Conclusions have been drawn regarding typical lateral impact situations and the effectiveness of seatbelts in lateral impacts.
Technical Paper

Response Ratio Development for Lateral Pendulum Impact with Porcine Thorax and Abdomen Surrogate Equivalents

2020-03-31
2019-22-0007
There has been recent progress over the past 10 years in research comparing 6-year-old thoracic and abdominal response of pediatric volunteers, pediatric post mortem human subjects (PMHS), animal surrogates, and 6-year-old ATDs. Although progress has been made to guide scaling laws of adult to pediatric thorax and abdomen data for use in ATD design and development of finite element models, further effort is needed, particularly with respect to lateral impacts. The objective of the current study was to use the impact response data of age equivalent swine from Yaek et al. (2018) to assess the validity of scaling laws used to develop lateral impact response corridors from adult porcine surrogate equivalents (PSE) to the 3-year-old, 6-year-old, and 10-year-old for the thorax and abdominal body regions.
Technical Paper

Biomechanical Response of the Pediatric Abdomen, Part 1: Development of an Experimental Model and Quantification of Structural Response to Dynamic Belt Loading

2006-11-06
2006-22-0001
The abdomen is the second most commonly injured region in children using adult seat belts, but engineers are limited in their efforts to design systems that mitigate these injuries since no current pediatric dummy has the capability to quantify injury risk from loading to the abdomen. This paper develops a porcine (sus scrofa domestica) model of the 6-year-old human's abdomen, and then defines the biomechanical response of this abdominal model. First, a detailed abdominal necropsy study was undertaken, which involved collecting a series of anthropometric measurements and organ masses on 25 swine, ranging in age from 14 to 429 days (4-101 kg mass). These were then compared to the corresponding human quantities to identify the best porcine representation of a 6-year-old human's abdomen. This was determined to be a pig of age 77 days, and whole-body mass of 21.4 kg.
Technical Paper

Development and Validation of Age-Dependent FE Human Models of a Mid-Sized Male Thorax

2010-11-03
2010-22-0017
The increasing number of people over 65 years old (YO) is an important research topic in the area of impact biomechanics, and finite element (FE) modeling can provide valuable support for related research. There were three objectives of this study: (1) Estimation of the representative age of the previously documented Ford Human Body Model (FHBM)~an FE model which approximates the geometry and mass of a mid-sized male, (2) Development of FE models representing two additional ages, and (3) Validation of the resulting three models to the extent possible with respect to available physical tests. Specifically, the geometry of the model was compared to published data relating rib angles to age, and the mechanical properties of different simulated tissues were compared to a number of published aging functions. The FHBM was determined to represent a 53-59 YO mid-sized male. The aforementioned aging functions were used to develop FE models representing two additional ages: 35 and 75 YO.
Technical Paper

Mechanical Properties of the Shoulder Ligaments under Dynamic Loading

2004-11-01
2004-22-0006
Thirty-three fresh human cadaver shoulders were harvested and bone-ligament-bone specimens of acromioclavicular joint, coracoclavicular joint and sternoclavicular joint were obtained. A test fixture and clamps specifically designed for this ligament study and a high-speed Instron machine were used. One quasi-static rate (nominally 0.1 %/sec) and two high rates (nominally, high rate 1 = 40,000 %/sec and high rate 2 = 15,000 %/sec) were used in this study. In the acromioclavicular joint tests, ligament failure was the most common failure mode. Bone fractures occurred most often at the clavicle rather than acromion. In the coracoclavicular joint tests, the majority of specimens failed at the ligament and bone fractures occurred at the coracoid. In the sternoclavicular joint tests, the specimen failed at the bone in most cases. In the acromioclavicular joint and coracoclavicular joint tests, high rate 2 tests and quasi-static tests had more bone fracture cases than high rate 1 tests.