High Strain Rate Mechanical Properties of Long Glass Fiber Filled Polypropylene and Nylon

2014-04-01
2014-01-1056
The American Chemistry Council sponsored program to optimize a specimen design for use in high strain rate testing of long fiber-reinforced thermoplastics (LFRT) was experimentally validated through testing of injection molded long glass-filled polypropylene (LGFPP) and long glass filled Nylon ® (Nylon). It was demonstrated that the dynamic specimen geometry generated valid results for LFRT tensile tests in the quasi-static through 400/s regime. Optimum specimen size depended on the maximum test rates and end use of the data. The program results provide a basis to select specimen parameters to appropriately represent LFRT or similar materials for comparison or material property testing. Tests established the effects of injection technique; strain rate (nominal 0.1/s to 400/s); fiber fill content (20wt%, 30wt%, 40wt%), specimen type and width, panel thickness, distance to the fill gate, flow orientation, and material homogeneity.