Refine Your Search

Search Results

Viewing 1 to 10 of 10
Technical Paper

Methods of Controlling the Loop Heat Pipe Operating Temperature

2008-06-29
2008-01-1998
The operating temperature of a loop heat pipe (LHP) is governed by the saturation temperature of its compensation chamber (CC); the latter is in turn determined by the balance among the heat leak from the evaporator to the CC, the amount of subcooling carried by the liquid returning to the CC, and the heat exchanged between the CC and ambient. Thus, the operating temperature of an LHP is a function of the evaporator heat input and the condenser sink temperature. The LHP operating temperature can be controlled at a desired set point by actively controlling the CC temperature. Several methods have been developed to control the CC temperature, including direct heating of the CC, coupling block, heat exchanger and separate subcooler, variable conductance heat pipe, vapor by-pass valve, secondary evaporator, and thermoelectric converter. The paper discusses the operating principles, advantages and disadvantages of each method.
Technical Paper

Testing of a Loop Heat Pipe with Two Evaporators and Two Condensers

2001-07-09
2001-01-2190
Most existing loop heat pipes (LHPs) consist of one single evaporator and one single condenser. LHPs with multiple evaporators are very desirable for cooling multiple heat sources or a heat source with large thermal footprints. Extending the current LHP technology to include multiple evaporators and multiple condensers faces some challenges, including operating temperature stability, adaptability of loop operation to rapid power and sink temperature transients, and sizing of the compensation chambers (CCs). This paper describes an overview of an extensive testing program for an LHP with two evaporators and two condensers. Tests performed include start-up, power cycle, sink temperature cycle, CC temperature cycle, and capillary limit. Test results showed that the loop could be started successfully in most cases, and the operating temperature was a function of the total heat load, heat load distribution between the two evaporators, condenser sink temperature and ambient temperature.
Technical Paper

Testing of Flight Components for the Capillary Pumped Loop Flight Experiment

1993-07-01
932235
The Capillary Pumped Loop Flight Experiment (CAPL) is a prototype of the Earth Observing System (EOS) instrument thermal control systems. Four CAPL flight hardware components were tested in the Instrument Thermal Test Bed at NASA's Goddard Space Flight Center. The components tested were the capillary cold plates, capillary starter pump, heat pipe heat exchangers (HPHXs), and reservoir. The testing verified that all components meet or exceed their individual performance specifications. Consequently, the components have been integrated into the CAPL experiment which will be flown on the Space Shuttle in late 1993.
Technical Paper

Flow Visualization within a Capillary Evaporator

1993-07-01
932236
A Capillary Pumped Loop (CPL) is an advanced two-phase heat transport device which utilizes capillary forces developed within porous wicks to move a working fluid. The advantage this system has over conventional thermal management systems is its ability to transfer large heat loads over long distances at a controlled temperature. Extensive ground testing and two flight experiments have been performed over the past decade which have demonstrated the potential of the CPL as a reliable and versatile thermal control system for space applications. While the performance of CPL's as “black boxes” is now well understood, the internal thermo-fluid dynamics in a CPL are poorly known due to the difficulty of taking internal measurements. In order to visualize transient thermohydraulic processes occurring inside an evaporator, a see-through capillary evaporator was built and tested at NASA's Goddard Space Flight Center.
Technical Paper

Loop Heat Pipe Operating Temperature Dependence on Liquid Line Return Temperature

2004-07-19
2004-01-2506
A Loop Heat Pipe (LHP) is a passive two-phase heat transfer device developed and successfully employed to cool spacecraft (satellite) electronics. The intrinsic benefits of this technology (lightweight, small volume, high thermal conductance) make it an attractive potential solution to many problems in ground vehicle thermal management. As most published LHP research has focused on cooling orbiting spacecraft components, there is little knowledge of how LHPs perform under the temperature extremes (−40°C to 40°C) and diurnal/seasonal fluctuations anticipated with terrestrial applications. Ambient temperature extremes mandate consideration of transport line heat exchange with the surroundings (parasitic losses/gains). This paper presents results from an experimental investigation of liquid line return temperature impact on system performance for sink temperatures from −30°C to 40°C and evaporator loads up to 700 Watts.
Technical Paper

Testing of a Miniature Loop Heat Pipe Using a Thermal Electrical Cooler for Temperature Control

2004-07-19
2004-01-2505
This paper describes the design and testing of a miniature loop heat pipe (LHP) having a 7 mm outer diameter (O.D.) evaporator with an integral compensation chamber (CC). The vapor line and liquid line are made of 1.59mm O.D. stainless steel tubing. A thermoelectric (TEC) is installed on the CC and the hot side of the TEC is connected to the evaporator through a copper strap. By changing the direction of the electric current provided by a bi-polar power supply, the TEC can heat or cool the CC. Tests performed in the laboratory included start-up, power cycle, sink temperature cycle, and CC temperature control with the test article being placed in horizontal and vertical positions. The LHP demonstrated very robust operation in all tests where the heat load varied between 0.5W and 140W, and the sink temperature varied between 243K and 293K. The heat leak from the evaporator to the CC was extremely small.
Technical Paper

Flight Testing of a Cryogenic Capillary Pumped Loop

1999-08-02
1999-01-2627
This paper describes the flight test results of the fifth generation cryogenic capillary pumped loop (CCPL-5) which flew on the Space Shuttle STS-95 in October of 1998 as part of the CRYOTSU Flight Experiment. This flight was the first in-space demonstration of the CCPL, a lightweight heat transport and thermal switching device for future integrated cryogenic bus systems. The CCPL-5 utilized nitrogen as the working fluid and operated between 75K and 110K. Flight results indicated excellent performance of the CCPL-5 in a micro-gravity environment. The CCPL could start from a supercritical condition in all tests, and the reservoir set point temperature controlled the loop operating temperature regardless of changes in the heat load and/or the sink temperature. In addition, the loop demonstrated successful operation with heat loads ranging from 0.5W to 3W, as well as with parasitic heat loads alone.
Technical Paper

A Parametric Study of Performance Characteristics of Loop Heat Pipes

1999-07-12
1999-01-2006
A parametric study of performance characteristics of a Loop Heat Pipe (LHP) is presented. A mathematical model, based on the steady-state energy conservation equations, is used. The calculations are performed by varying the operation conditions (heat load, sink and ambient temperatures, and elevation) and the LHP design parameters (working fluid, transport length size, external thermal conductance of the condenser and wick properties). The results are illustrated on LHP performance curves (saturation temperature as a function of applied power). All the results are compared with a baseline configuration to analyze the effects of different parameters. Operating limits due to various constraints such as heat transport limit, capillary pressure limit and the vapor pressure limit are discussed.
Technical Paper

Thermal Performance and Operational Characteristics of Loop Heat Pipe (NRL LHP)

1998-07-13
981813
In this paper, results of the NRL LHP experimental studies, conducted by Naval Research Laboratory (NRL) and NASA Goddard Space Flight Center, will be presented. Emphasis in this test program is to examine the “turnkey” startup of the NRL LHP and its operational characteristics. Series of tests were performed, including startup tests, power cycling tests, low power tests, and high power tests. The NRL LHP has demonstrated very robust operations throughout the tests. In addition, hysteresis was found at low power operations. Importance of the two-phase dynamics in the evaporator core is realized, which has shown significant effects on loop operations.
Technical Paper

Operating Characteristics of Loop Heat Pipes

1999-07-12
1999-01-2007
The loop heat pipe (LHP) was invented in Russia in the early 1980’s. It is a two-phase heat transfer device that utilizes the evaporation and condensation of a working fluid to transfer heat, and the capillary forces developed in fine porous wicks to circulate the fluid. The LHP is known for its high pumping capability and robust operation because it uses fine-pored metal wicks and the integral evaporator/hydro-accumulator design. It has gained rapid acceptance in recent years as a thermal control device in space applications. This paper presents an overview of the LHP operation. The physical processes and the thermal-hydraulic behaviors of the LHP are first described. Operating characteristics as functions of various parameters including the heat load, sink temperature, ambient temperature, and elevation are presented. Peculiar behaviors in LHP operation such as temperature hysteresis and temperature overshoot during start-up are explained.
X