Technical Paper

Humidity Condensate Sampling System for Shuttle, Mir and International Space Station

1998-07-13
981764
Archival sampling of potable water and condensate for ground laboratory analysis has been an important part of the Shuttle-Mir program because of coolant leaks and other events on Mir that have affected water quality. We report here the development of and preliminary results from a novel device for single phase humidity condensate collection at system pressures. The sampler consists of a commercial-off-the-shelf Teflon® bladder and a custom reinforced Nomex® restraint that is sized properly to absorb the stress of applied pressures. A plastic Luer-Lock disconnect, with poppet actuated by a mating Luer-Lock fitting, prevents the contents from being spilled during transport. In principle, a sampler of any volume can be designed. The empty mass of the reusable one-liter sampler is only 63 grams. Several designs were pressure tested and found to withstand more than 3 atmospheres well in excess of typical spacecraft water or wastewater system pressures.
Technical Paper

Shuttle Potable Water Quality from STS-26 to STS-114

2006-07-17
2006-01-2014
Potable water for the Shuttle orbiter is generated as a by-product of electricity production by the fuel cells. Water from the fuel cells flows through a Microbial Check Valve (MCV), which releases biocidal iodine into the water before it enters one of four storage tanks. Potable water is dispensed on-orbit at the rehydration unit of the galley. Due to crew health concerns, iodine removal hardware is installed in the chilled water inlet line to the galley to remove the iodine from the potable water before it is consumed by the crew. The Shuttle water system is sampled to ensure water quality is maintained during all operational phases from the disinfection of the ground servicing equipment through the completion of each mission. This paper describes and summarizes the Shuttle water quality requirements, the servicing of the Shuttle water system, the collection and analysis of Shuttle water samples, and the results of the analyses.
Technical Paper

Chemical Characterization of U.S. Lab Condensate

2006-07-17
2006-01-2016
Approximately 50% of the water consumed by International Space Station crewmembers is water recovered from cabin humidity condensate. Condensing heat exchangers in the Russian Service Module (SM) and the United States On-Orbit Segment (USOS) are used to control cabin humidity levels. In the SM, humidity condensate flows directly from the heat exchanger to a water recovery system. In the USOS, a metal bellows tank located in the US Laboratory Module (LAB) collects and stores condensate, which is periodically off-loaded in about 20-liter batches to Contingency Water Containers (CWCs). The CWCs can then be transferred to the SM and connected to a Condensate Feed Unit that pumps the condensate from the CWCs into the water recovery system for processing. Samples of the condensate in the tank are collected during the off-loads and returned to Earth for analyses.
Technical Paper

Advanced Development of the Regenerative Microbial Check Valve

1993-07-01
932175
The Microbial Check Valve (MCV) is a reloadable flow-through canister containing iodinated ion exchange resin, which is used aboard the Shuttle Orbiter as a disinfectant to maintain water potability. The MCV exhibits a significant contact kill and imparts a biocidal residual I2 concentration to the effluent. MCVs in current use have nominal 30 day lives. MCVs baselined for Space Station Freedom will have 90 day lives, and will require replacement 120 times over 30 years. Means to extend MCV life are desirable to minimize resupply penalties. New technology has been developed for fully autonomous in situ regeneration of an expended MCV canister. The Regenerative Microbial Check Valve (RMCV) consists of an MCV, a packed bed of crystalline I2, a flow diverter valve, an in-line iodine monitor and a microcontroller. During regeneration, flow is directed first through the packed I2 bed and then into the MCV where the resin is replenished.
Technical Paper

Chemical Analysis of Potable Water and Humidity Condensate: Phase One Final Results and Lessons Learned

1999-07-12
1999-01-2028
Twenty-nine recycled water, eight stored (ground-supplied) water, and twenty-eight humidity condensate samples were collected on board the Mir Space Station during the Phase One Program (1995-1998). These samples were analyzed to determine potability of the recycled and ground-supplied water, to support the development of water quality monitoring procedures and standards, and to assist in the development of water reclamation hardware. This paper describes and summarizes the results of these analyses and lists the lessons learned from this project. Results show that the recycled water and stored water on board Mir, in general, met NASA, Russian Space Agency (RSA), and U.S. Environmental Protection Agency (EPA) standards.
Technical Paper

A Spectrophotometric Analyzer for Aqueous Samples in Microgravity

1999-07-12
1999-01-2032
The development of a spectrophotometric analyzer for use on water samples in microgravity environments is discussed. The instrument is constructed around a commercial spectrophotometer, the Hewlett-Packard HP8453, with a separate turbidimetric analyzer, here a modified Hach 2100P ratio turbidimeter. Flow-through sample cells were constructed for each instrument to support microgravity use and sample deaeration. Spectrophotometric analyses on aqueous samples on orbit are sensitive to the presence of undissolved gases in the samples. In a micro-g environment, free gas in samples can and does remain suspended, clouding the mixture and interfering with spectral optical density measurements. This paper discusses the design of a spectrophotometric analyzer, with particular emphasis on the merits of two approaches to eliminating free gas interferences in on-orbit water analyses: hyperbaric gas redissolution and deaeration across a hydrophobic membrane.
Technical Paper

Reduction in the Iodine Content of Shuttle Drinking Water: Lessons Learned

1999-07-12
1999-01-2117
Iodine is the disinfectant used in U.S. spacecraft potable water systems. Recent long-term testing on human subjects has raised concerns about excessive iodine consumption. Efforts to reduce iodine consumption by Shuttle crews were initiated on STS-87, using hardware originally designed to deiodinate Shuttle water prior to transfer to the Mir Space Station. This hardware has several negative aspects when used for Shuttle galley operations, and efforts to develop a practical alternative were initiated under a compressed development schedule. The alternative Low Iodine Residual System (LIRS) was flown as a Detailed Test Objective on STS-95. On-orbit, the LIRS imparted an adverse taste to the water due to the presence of trialkylamines that had not been detected during development and certification testing. A post-flight investigation revealed that the trialkylamines were released during gamma sterilization of the LIRS resin materials.
Technical Paper

Chemical Analysis and Water Recovery Testing of Shuttle-Mir Humidity Condensate

1999-07-12
1999-01-2029
Humidity condensate collected and processed in-flight is an important component of a space station drinking water supply. Water recovery systems in general are designed to handle finite concentrations of specific chemical components. Previous analyses of condensate derived from spacecraft and ground sources showed considerable variation in composition. Consequently, an investigation was conducted to collect condensate on the Shuttle while the vehicle was docked to Mir, and return the condensate to Earth for testing. This scenario emulates an early ISS configuration during a Shuttle docking, because the atmospheres intermix during docking and the condensate composition should reflect that. During the STS-89 and STS-91 flights, a total volume of 50 liters of condensate was collected and returned. Inorganic and organic chemical analyses were performed on aliquots of the fluid.