Refine Your Search

Search Results

Viewing 1 to 11 of 11
Journal Article

Modeling of a Reversible Air Conditioning-Heat Pump System for Electric Vehicles

2016-04-05
2016-01-0261
This paper presents a simulation model for a reversible air conditioning and heat pump system for electric vehicles. The system contains a variable speed compressor, three microchannel heat exchangers, an accumulator, and two electronic expansion valves. Heat exchangers are solved by discretizing into cells. Compressor and accumulator models are developed by fitting data with physical insights. Expansion valves are modeled by isenthalpic processes. System performance is calculated by connecting all parts in the same way as the physical system and solved iteratively. The model is reasonably validated against experimental data from a separate experimental study. Future improvement is needed to take into account maldistribution in outdoor heat exchanger working as an evaporator in HP mode. Charge retention in components also requires further study.
Technical Paper

Modeling of an Integrated Internal Heat Exchanger and Accumulator in R744 Mobile Air-Conditioning Applications

2020-04-14
2020-01-0153
Carbon dioxide (CO2 or R744) is a promising next-generation refrigerant for mobile air-conditioning applications (MAC), which has the advantages of good heating performance in cold climates and environmental-friendly properties. This paper presents a simulation model of an integrated internal heat exchanger (IHX) and accumulator (Acc) using the finite volume method. The results are validated by a group of experimental data collected with different transcritical R744 mobile air-conditioner and heat pump (MHP) systems, and the error was within ±10%. The impacts of refrigerant mass flow rate and operating temperatures on the heat transfer rate of the IHX, improvement on refrigeration capacity and the liquid level in the Acc were studied. Results show that the net benefits of IHX are significant in AC mode, while it helps preventing flooding of the compressor in MHP mode.
Technical Paper

Refrigerant Charge Imbalance in a Mobile Reversible Air Conditioning-Heat Pump System

2017-03-28
2017-01-0177
This paper presents the study of refrigerant charge imbalance between A/C (cooling) mode and HP (heating) mode of a mobile reversible system. Sensitivities of cooling and heating capacity and energy efficiency with respect to refrigerant charge were investigated. Optimum refrigerant charge level for A/C mode was found to be larger than that for HP mode, primarily due to larger condenser size in A/C mode. Refrigerant charge retention in components at both modes were measured in the lab by quick close valve method. Modeling of charge retention in heat exchangers was compared to experimental measurements. Effect of charge imbalance on oil circulation was also discussed.
Technical Paper

Application of Intermediate Vapor Bypass to Mobile Heat Pump System: Extending Operating Range to Lower Ambient Temperature with Low Pressure Low GWP Fluid

2018-04-03
2018-01-0071
With market share of electric vehicles continue to grow, there is an increasing demand of mobile heat pump for cabin climate control, as it has much higher energy efficiency when compared to electric heating and helps to cut drive range reduction. One big challenge of heat pump systems is that their heating capacities drop significantly when operating at very low ambient temperature, especially for those with low pressure refrigerants. This paper presents a way to improve low ambient temperature heating performance by using intermediate vapor bypass with the outdoor heat exchanger, which works as an evaporator in heat pump mode. The experimental results show a 35% increase of heating capacity at −20 °C ambient with the improved system as compared to the baseline, and heating performance factor also slightly increased when the system is working at higher ambient temperature to reach the same heating capacity as the baseline.
Technical Paper

Performance Characteristics of a Mobile Heat Pump System at Low Ambient Temperature

2018-04-03
2018-01-0076
The demand for mobile heat pump systems increases with the growing popularity of electric vehicles. One big challenge of such systems using low pressure refrigerant is the substantial drop of heating capacity at low ambient temperature conditions, when heat is most needed. The low suction density associated with low operating pressure in the evaporator is the major reason for the capacity drop. In extremely low ambient temperature, compressor speed may need to be regulated in order to prevent suction pressure going below atmospheric pressure, hence further reducing heat pumping capability. Other factors like pressure drop induced temperature glide and refrigerant maldistribution in the outdoor evaporator also weakens the system ability to absorb heat from ambient air. This paper presents detailed and in-depth analysis of the performance and limiting factors on low ambient temperature operation of a mobile heat pump system using refrigerant R1234yf.
Technical Paper

A Sensor for Estimating the Liquid Mass Fraction of the Refrigerant Exiting an Evaporator

2000-03-06
2000-01-0976
A traditional method of controlling evaporator superheat in a vapor compression air conditioning system is the thermostatic expansion valve (TXV). Such systems are often used in automotive applications. The TXV depends on superheat to adjust the valve opening. Unfortunately, any amount of superheat causes that evaporator to operate at reduced capacity due to dramatically lower heat transfer coefficients in the superheated region. In addition, oil circulation back to the compressor is impeded. The cold lubricant almost devoid of dissolved refrigerant is quite viscous and clings to the evaporator walls. A system that could control an air conditioner to operate with no superheat would either decrease the size of its existing evaporator while maintaining the same capacity, or potentially increase its capacity with its original evaporator. Also, oil circulation back to the compressor would be improved.
Technical Paper

Refrigerant Expansion Noise Propagation Through Downstream Tube Walls

1999-03-01
1999-01-1197
Reductions of noise in vehicle passenger compartments in recent years have made some previously undetectable noises audible. Expansion devices used in automobile air conditioning systems are known producers of noise. The fact that these devices are mounted very close to the passengers increases the problems associated with the reduction of this noise. The understanding of the propagation mechanisms from the noise generated in the refrigerant by the expansion device, through the tube and evaporator walls, and finally to the outside air is important. This paper will focus on how noise from expansion devices is transmitted through tube walls downstream of the expansion valve.
Technical Paper

Refrigerant-Oil Flow at the Compressor Discharge

2016-04-05
2016-01-0247
Automotive air conditioning compressor produces an annular-mist flow consisting of gas-phase refrigerant flow with oil film and oil droplets. This paper reports a method to calculate the oil retention and oil circulation ratio based on oil film thickness, wave speed, oil droplet size, oil droplet speed, and mass flow rate. Oil flow parameters are measured by high-speed camera capture and video processing in a non-invasive way. The estimated oil retention and oil circulation ratio results are compared quantitatively with the measurements from system experiments under different compressor outlet gas superficial velocity. The agreement between video result and sampling measurement shows that this method can be applied in other annular-mist flow analysis. It is also shown that most of the oil exists in film from the mass point of view while oil droplets contributes more to the oil mass flow rate because they travel in a much higher speed.
Technical Paper

Experimental Study of an Air Conditioning-Heat Pump System for Electric Vehicles

2016-04-05
2016-01-0257
This paper presents the experimentally obtained performance characteristics of an air conditioning-heat pump system that uses heat exchangers from a commercially available Nissan Leaf EV. It was found that refrigerant charge needed for cooling operation was larger than that for heating function with the test setup. The effects of: a). indoor air flow rate, b). outdoor air flow rate, and c). compressor speed on heating capacity and energy efficiency were explored and presented. Appropriate opening size of expansion valve that controlled subcooling for better energy efficiency was discussed and results were presented. Expansion valve opening size also strongly affected charge migration. Warm-up tests at different ambient conditions showed the necessity of a secondary heater to be reserved for very low ambient temperature.
Technical Paper

Effect of Flow Regime in the Horizontal Inlet Header on Refrigerant-Oil Mixture Distribution in a MAC Microchannel Evaporator

2014-04-01
2014-01-0701
The effect of lubricant on distribution is investigated by relating the flow regime in the horizontal inlet header and the corresponding infrared image of the evaporator. Visualization of the flow regime is performed by high-speed camera. R134a is used as the refrigerant with PAG 46 as lubricant, forming foam in all flow regimes. Quantitative information including foam location, foam layer thickness is obtained using a matlab-based video processing program. Oil circulation rate effect on flow regime is analyzed quantitatively.
Technical Paper

Lubricant Impact on R134a Distribution and Microchannel Heat Exchanger Performance

2014-04-01
2014-01-0706
Lubricant in compressor usually flows out with refrigerant. Thus, it is evitable for lubricant to be present in the heat exchanger, which significantly affects the heat exchanger performance. This paper is to investigate the effects of PAG oil on R134a distribution in the microchannel heat exchanger (MCHX) with vertical headers and to provide a tool to model R134a (with oil) distribution and its effects on MCHX capacity. The flow configuration in MCHX under the heat pump mode of the reversible system is mimicked in the experimental facility: refrigerant-oil mixture is fed into the test header from the bottom pass and exits through the top pass. It is found that a small amount of oil (OCR=0.5%) worsen the distribution. But further increasing OCR to 2.5% and 4.7%, the distribution becomes better.
X