Refine Your Search

Search Results

Viewing 1 to 8 of 8
Technical Paper

A New Mechanism for Measuring Exhaust A/F

1993-11-01
932957
Exhaust gas air-fuel ratio (A/F) sensors are common devices in powertrain feedback control systems aimed at minimizing emissions. Both resistive (using TiO2) and electrochemical (using ZrO2) mechanisms are used in the high temperature ceramic devices now being employed. In this work a new mechanism for making the measurement is presented based on the change in the workfunction of a Pt film in interaction with the exhaust gas. In particular it is found that the workfunction of Pt increases reversibly by approximately 0.7 V at that point (the stoichiometric ratio) where the exhaust changes from rich to lean conditions. This increase arises from the adsorption of O2 on the Pt surface. On returning to rich conditions, catalytic reaction of the adsorbed oxygen with reducing species returns the workfunction to its original value. Two methods, one capacitive and one thermionic, for electrically sensing this workfunction change and thus providing for a practical device are discussed.
Technical Paper

Comparison of Engine Dynamometer Test Procedures

1993-11-01
933039
A comparison between ‘Quasi-Transient’ and Steady-State (SAE J1349) engine dynamometer horsepower test procedures was conducted to determine the degree of correlation between the two test methods. Measurements demonstrated that the peak horsepower and torque measured using both techniques was similar. This information is useful as a development tool, because the ‘Quasi-Transient’ procedure allows for data to be collected over the engine RPM range much faster then the Steady-State method, allowing for the accurate testing of more engine/exhaust configurations in a shorter amount of time.
Technical Paper

A Comparison of Time Domain and Frequency Domain Test Methods for Automotive Components

1994-11-01
942279
Frequency domain testing has had limited use in the past for durability evaluations of automotive components. Recent advances and new perspectives now make it a viable option. Using frequency domain testing for components, test times can be greatly reduced, resulting in considerable savings of time, money, and resources. Quality can be built into the component, thus making real-time subsystem and full vehicle testing and development more meaningful. Time domain testing historically started with block cycle histogram tests. Improved capabilities of computers, controllers, math procedures, and algorithms have led to real time simulation in the laboratory. Real time simulation is a time domain technique for duplicating real world environments using computer controlled multi-axial load inputs. It contains all phase information as in the recorded proving ground data. However, normal equipment limitations prevent the operation at higher frequencies.
Technical Paper

Development of the 6.8L V10 Heat Resisting Cast-Steel Exhaust Manifold

1996-10-01
962169
This paper presents the experience of Ford Motor Company and Hitachi Metals Ltd., in the development and design of the exhaust manifolds for the new 1997 Ford 6.8L, Vl0 gasoline truck engine. Due to the high-exhaust temperature 1000 °C (1832 °F), heat-resisting nodular graphite irons, such as high-silicon molybdenum iron and austenitic iron with nickel cannot meet the durability requirements, mainly thermal fatigue evaluation. The joint effort by both companies include initial manifold design, prototype development, engine simulation bench testing, failure analysis, material selections (ferritic or austenitic cast steel), production processes (casting, machining) and final inspection. This experience can well be applied to the design and development of new cast stainless-steel exhaust manifolds in the future. This is valid due to the fact that US EPA is requiring all car manufacturers to meet the new Bag 6-Emission Standards which will result in increased exhaust gas temperature.
Technical Paper

1983 Ford Ranger Truck HSLA Steel Wheel

1982-02-01
820019
The demand for improved fuel economy in both cars and trucks has emphasized the need for lighter weight components. The application of high strength steel to wheels, both rim and disc, represents a significant opportunity for the automotive industry. This paper discusses the Ranger HSLA wheel program that achieved a 9.7 lbs. per vehicle weight savings relative to a plain carbon steel wheel of the same design. It describes the Ranger wheel specifications, the material selection, the metallurgical considerations of applying HSLA to wheels, and HSLA arc and flash butt welding. The Ranger wheel design and the development of the manufacturing process is discussed, including design modifications to accommodate the lighter gage. The results demonstrate that wheels can be successfully manufactured from low sulfur 60XK HSLA steel in a conventional high volume process (stamped disc and rolled rim) to meet all wheel performance requirements and achieve a significant weight reduction.
Technical Paper

Fatigue Service Histories: Techniques for Data Collection and History Reconstruction

1982-02-01
820093
A number of service fatigue history summarization statistics are examined for their suitability in regenerating the history in the laboratory. Evaluation criteria applied include: fatigue damage-per-level equivalence, implementation simplicity, waveform similarity, and fatigue life equivalence. The results suggest that a three-dimensional “From-To” matrix that includes sequence information about the original variable amplitude histories, is optimal for service history reconstruction.
Technical Paper

The Salt Spray Test - Past, Present, and Future

1983-12-05
831815
The salt spray test has been an industry wide standard corrosion test since its conception in 1914. A literary review of its history shows that it has· always been thought of as inconsistent and unreliable but, for a variety of reasons, has continued to be used. A study of more than 55 salt spray cabinets was performed using a controlled lot of parts and questionnaires on cabinet operation. Although the tested parts varied from mildly corroded to extremely rusted no factor could be found to account for the differences. Although the test has its uses it should be studied by an industry formed committee which should make recommendations as to further standardization and corrections to the test. A lengthy chronological bibliography aids the reader in further study and reference.
Technical Paper

Dezincification Corrosion and Its Prevention for Copper/Brass Radiators

1983-12-05
831829
The use of a corrosion inhibited arsenical brass alloy for copper/brass radiator tubes has been identified as an effective means to protect the radiator tubes from external dezincification attack, which is generally caused by an exposure to excessive road salts in the regions such as Montreal and Toronto in Canada. Laboratory test methods, their results and field data verifying improved radiator life are presented.