The purpose of this SAE Aerospace Recommended Practice (ARP) is to describe key features that should be incorporated in the lavatory smoke detector system. Consideration has been given to existing requirements of the FAA and to recommendations of aircraft operators and manufacturers. This document is deliberately not specific in all areas in order to maximize the freedom to use state-of-the-art design and manufacturing technologies. Safe, reliable, and effective lavatory smoke detectors remain the primary goal of the document.
The purpose of this SAE Aerospace Recommended Practice (ARP) is to describe key features that should be incorporated in the lavatory smoke detector system. Consideration has been given to existing requirements of the FAA and to recommendations of aircraft operators and manufacturers. This document is deliberately not specific in all areas in order to maximize the freedom to use state-of-the-art design and manufacturing technologies. Safe, reliable, and effective lavatory smoke detectors remain the primary goal of the document.
This ARP is to describe key features for the lavatory smoke detector. Consideration has been given to existing requirements of the FAA, to recommendations of aircraft operators and manufacturers. The ARP is deliberately not specific in all areas in order to maximize potential supplier's freedom to use the state-of-the-art design and manufacturing technologies. Safe, reliable, and effective lavatory smoke detectors remain the primary goal of the ARP.
The methods and designs presented herein shall not be construed as being the only means of accomplishing these accommodations. This document applies to all transport category aircraft using features required by Department of Transportation Regulations CFR382. Passengers with ambulatory disabilities for whom provisions shall be made on each airplane type and location(s) for their seating are defined in 14CFR382. The goal is to provide cabin service comparable to that available to other travelers without jeopardizing the safety of fellow passengers. This necessitates consideration of physical, neurological and sensory capabilities, and limitations of mobility impaired persons. With proper consideration and design implementation, it will be possible to serve the needs of the majority of the disabled population.
This Aerospace Recommended Practice (ARP) sets forth general specifications for the location, accessibility and restraint for those items of survival, emergency, and miscellaneous equipment which are intended to be used by the operating flight crew, and which are stowed on or near the flight deck.
This recommended practice sets forth general specifications for the location, accessibility and restraint for those items of survival, emergency, and miscellaneous equipment which are intended to be used by the operating flight crew, and which are stowed on or near the flight deck.
This SAE Aerospace Recommended Practice (ARP) provides information and recommended guidelines for handling carry-on baggage prior to emergencies and during the emergency evacuation of transport category aircraft. Recommendations are provided on limiting the size, amount, and weight of carry-on baggage brought into the cabin, improved stowage of carry-on baggage to minimize hazards to passengers in flight and during emergency evacuations, and procedures to ensure carry-on baggage is not removed during an emergency evacuation.
This SAE Aerospace Recommended Practice (ARP) provides information and recommended guidelines for handling carry-on baggage prior to emergencies and during the emergency evacuation of transport category aircraft. Recommendations are provided on limiting the size, amount, and weight of carry-on baggage brought into the cabin, improved stowage of carry-on baggage to minimize hazards to passengers in flight and during emergency evacuations, and procedures to ensure carry-on baggage is not removed during an emergency evacuation.
This SAE Aerospace Recommended Practice (ARP) establishes recommendations with respect to personnel and aircraft safety for the design of lavatory compartments in commercial aircraft. Consideration should be given to the fact the lavatory compartment is an area in which the passenger is not under direct observation of the flight attendants.
This SAE Aerospace Recommended Practice (ARP) establishes recommendations with respect to personnel and aircraft safety for the design of lavatory compartments in commercial aircraft. Consideration should be given to the fact the lavatory compartment is an area in which the passenger is not under direct observation of the flight attendants.
This SAE Aerospace Information Report (AIR) provides guidance criteria for the storage of personal wheelchairs in the passenger compartment of transport category aircraft, which have not been provided by the air carrier and are designated for the sole use of the passenger requiring such assistance.
This SAE Aerospace Information Report (AIR) provides guidance criteria for the storage of personal wheelchairs in the passenger compartment of transport category aircraft, which have not been provided by the air carrier and are designated for the sole use of the passenger requiring such assistance.
This Aerospace Information Report (AIR) provides information about and suggests guidelines for handling carry-on items prior to and during the emergency evacuation of transport aircraft.