Refine Your Search

Search Results

Viewing 1 to 16 of 16
Technical Paper

The Effects of Small Seat Swiveling Angles on Occupant Responses during a Frontal Impact

2020-04-14
2020-01-0571
In highly automated vehicles (HAVs), new seat configurations may be desirable to allow occupants to perform new activities. One of the current HAV concepts is the swiveled seat layout, which might facilitate communication between occupants. The main objective of this study was to investigate the effects of seat swiveling angles on occupant kinematics and injury risk predicted by a Human Body Model (HBM) during a frontal impact. A detailed 50th percentile male HBM (GHBMC M50-O) was subjected to two frontal crash pulses in a sled setup. The model was positioned on a semi-rigid seat and restrained using a pre-inflated airbag and a three-point seatbelt. Simulations included four seat swiveling angles (0, -10, -20, and -30 degrees), three occupant positions (Sedan driver, large VAN driver or Laptop user), two airbag initial locations (nominal or matching the head Y location), and the inclusion of lateral supports on the seat pan.
Technical Paper

Reconstruction Tests Design to Support the Correlation of Real Injuries with Dummy Readings

2012-10-02
2012-36-0456
From the many sub-tasks of the four study areas of the EC CASPER project, this paper presents the following point: • Child protection improvements as a result of accident reconstructions and development of injury risk curves. The first step in achieving this aim was to collect real world in-depth road accident data involving restrained children, with injuries systematically coded using the AIS (Abbreviated Injury Scale, AAAM 1998). This activity identified the priority body regions to be protected (therefore requiring injury risk curves) and provided cases to be reconstructed in full scale crash tests. In such reconstructions dummy readings were correlated with the occupants' injuries in the real accident to develop injury risk curves (after validation checks for crash severity and dummy kinematics). At the same time, online and field surveys were carried out to identify the safety of children when travelling in cars.
Technical Paper

Analysis of a Real-World Crash Using Finite Element Modeling to Examine Traumatic Rupture of the Aorta

2005-04-11
2005-01-1293
One of the leading causes of death in automotive crashes is traumatic rupture of the aorta (TRA) or blunt aortic injury (BAI). The risk of fatality is high if an aortic injury is not detected and treated promptly. The objective of this study is to investigate TRA mechanisms using finite element (FE) simulations of reconstructed real-world accidents involving aortic injury. For this application, a case was obtained from the William Lehman Injury Research Center (WLIRC), which is a Crash Injury Research and Engineering Network (CIREN) center. In this selected crash, the case vehicle was struck on the left side with a Principal Direction of Force (PDoF) of 290 degrees. The side structure of the case vehicle crushed a maximum of 0.33 m. The total delta-V was estimated to be 6.2 m/s. The occupant, a 62-year old mid-sized male, was fatally injured. The occupant sustained multiple rib fractures, laceration of the right ventricle, and TRA, among other injuries.
Technical Paper

Lower Limb: Advanced FE Model and New Experimental Data

2001-11-01
2001-22-0022
The Lower Limb Model for Safety (LLMS) is a finite element model of the lower limb developed mainly for safety applications. It is based on a detailed description of the lower limb anatomy derived from CT and MRI scans collected on a subject close to a 50th percentile male. The main anatomical structures from ankle to hip (excluding the hip) were all modeled with deformable elements. The modeling of the foot and ankle region was based on a previous model Beillas et al. (1999) that has been modified. The global validation of the LLMS focused on the response of the isolated lower leg to axial loading, the response of the isolated knee to frontal and lateral impact, and the interaction of the whole model with a Hybrid III model in a sled environment, for a total of nine different set-ups. In order to better characterize the axial behavior of the lower leg, experiments conducted on cadaveric tibia and foot were reanalyzed and experimental corridors were proposed.
Technical Paper

Statistical Modeling of Human Liver Incorporating the Variations in Shape, Size, and Material Properties

2013-11-11
2013-22-0012
The liver is one of the most frequently injured abdominal organs during motor vehicle crashes. Realistic numerical assessments of liver injury risk for the entire occupant population require incorporating inter-subject variations into numerical models. The main objective of this study was to quantify the shape variations of human liver in a seated posture and the statistical distributions of its material properties. Statistical shape analysis was applied to construct shape models of the livers of 15 adult human subjects, recorded in a typical seated (occupant) posture. The principal component analysis was then utilized to obtain the modes of variation, the mean model, and 95% statistical boundary shape models. In addition, a total of 52 tensile tests were performed on the parenchyma of three fresh human livers at four loading rates (0.01, 0.1, 1, and 10 s−1) to characterize the rate-dependent and failure properties of the human liver.
Technical Paper

Observations on Pedestrian Pre-Crash Reactions during Simulated Accidents

2013-11-11
2013-22-0006
Pedestrian protection systems, both active and passive systems, are being introduced in the EU and Japan to comply with regulatory requirements. Their designs are specific and, in general, reflect an accident scenario of the pedestrian being struck on the side by a vehicle traveling at a maximum travel speed of 40 kph. The present study is an effort to quantify the effects of pedestrian reaction prior to an accident and identify characteristics that may help minimize or prevent the pedestrian to vehicle interaction. Accident situations were simulated with volunteers using a non-impacting methodology. Fifty one reactions from 23 volunteers of two age groups were observed. Most of the volunteers were found to run, step-back or stop in fright in a dangerous situation. Volunteer speed was an important parameter which could help in differentiating these reactions. Age related differences were also observed, both for reaction strategy and reaction times.
Technical Paper

Foot and Ankle Finite Element Modeling Using Ct-Scan Data

1999-10-10
99SC11
Although not life threatening in most cases, victims of lower extremity injuries frequently end up living with a poor quality of life. The implementations of airbag supplement restraint systems significantly reduce the incidence of head and chest injuries. However, the frequency of leg injuries remains high. Several finite element models of the foot and ankle have been developed to further the understanding of this injury mechanism. None of those models employed accurate geometry among various bony segments. The objective of this study is to develop a foot and ankle finite element model based on CT scan data so that joint geometry can be accurately represented. The model was validated against experimental data for several different configurations including typical car crash situations.
Technical Paper

Below Knee Impact Responses using Cadaveric Specimens

2004-11-01
2004-22-0004
Knee injuries represent about 10% of all injuries suffered during car crashes. Efforts to assess the injury risk to the posterior cruciate ligament (PCL) have been based on a study available in the literature (Viano et al., 1978), in which only two of the five knees tested had PCL ruptures. The aims of the current study were to repeat the study with a higher number of samples, study the effects of other soft tissues on knee response, and assess the adequacy of the experimental setup for the identification of a PCL tolerance. A total of 14 knees were tested using a high-speed materials testing machine. Eight were intact knees (with the patella and all the muscular and ligamentous structures), three were PCL-only knees (patella and all the muscular and ligamentous structures other than the PCL removed), and the last three were PCL-only knees with the tibia protected from bending fracture.
Technical Paper

The Effects of Posture and Subject-to-Subject Variations on the Position, Shape and Volume of Abdominal and Thoracic Organs

2009-11-02
2009-22-0005
In this study, the thorax and the abdomen of nine subjects were imaged in four postures using a positional MRI scanner. The four postures were seated, standing, forward-flexed and supine. They were selected to represent car occupants, pedestrians, cyclists and a typical position for medical imaging, respectively. Geometrical models of key anatomical structures were registered from the imaging dataset using a custom registration toolbox. The analysis of the images and models allowed the quantification of the respective effects of posture and subject-to-subject variation on the position, shape and volume of the abdominal organs, skeletal components and thoracic cavity. In summary, except for the supine posture, the organ volumes and their positions in the spinal frame were mostly unaffected by the posture.
Technical Paper

Abdominal Twin Pressure Sensors for the Assessment of Abdominal Injuries in Q Dummies: In-Dummy Evaluation and Performance in Accident Reconstructions

2012-10-29
2012-22-0010
The Abdominal Pressure Twin Sensors (APTS) for Q3 and Q6 dummies are composed of soft polyurethane bladders filled with fluid and equipped with pressure sensors. Implanted within the abdominal insert of child dummies, they can be used to detect abdominal loading due to the belt during frontal collisions. In the present study - which is part of the EC funded CASPER project - two versions of APTS (V1 and V2) were evaluated in abdominal belt compression tests, torso flexion test (V1 only) and two series of sled tests with degraded restraint conditions. The results suggest that the two versions have similar responses, and that the pressure sensitivity to torso flexion is limited. The APTS ability to detect abdominal loading in sled tests was also confirmed, with peak pressures typically below 1 bar when the belt loaded only the pelvis and the thorax (appropriate restraint) and values above that level when the abdomen was loaded directly (inappropriate restraint).
Technical Paper

Effect of Abdominal Loading Location on Liver Motion: Experimental Assessment using Ultrafast Ultrasound Imaging and Simulation with a Human Body Model

2016-11-07
2016-22-0003
A protocol based on ultrafast ultrasound imaging was applied to study the in situ motion of the liver while the abdomen was subjected to compressive loading at 3 m/s by a hemispherical impactor or a seatbelt. The loading was applied to various locations between the lower abdomen and the mid thorax while feature points inside the liver were followed on the ultrasound movie (2000 frames per second). Based on tests performed on five post mortem human surrogates (including four tested in the current study), trends were found between the loading location and feature point trajectory parameters such as the initial angle of motion or the peak displacement in the direction of impact. The impactor tests were then simulated using the GHBMC M50 human body model that was globally scaled to the dimensions of each surrogate. Some of the experimental trends observed could be reproduced in the simulations (e.g. initial angle) while others differed more widely (e.g. final caudal motion).
Technical Paper

Structural Response of Lower Leg Muscles in Compression: A Low Impact Energy Study Employing Volunteers, Cadavers and the Hybrid III

2002-11-11
2002-22-0012
Little has been reported in the literature on the compressive properties of muscle. These data are needed for the development of finite element models that address impact of the muscles, especially in the study of pedestrian impact. Tests were conducted to characterize the compressive response of muscle. Volunteers, cadaveric specimens and a Hybrid III dummy were impacted in the posterior and lateral aspect of the lower leg using a free flying pendulum. Volunteer muscles were tested while tensed and relaxed. The effects of muscle tension were found to influence results, especially in posterior leg impacts. Cadaveric response was found to be similar to that of the relaxed volunteer. The resulting data can be used to identify a material law using an inverse method.
Technical Paper

The Influence of Surrogate Blood Vessels on the Impact Response of a Physical Model of the Brain

2004-11-01
2004-22-0012
Cerebral blood vessels are an integral part of the brain and may play a role in the response of the brain to impact. The purpose of this study was to quantify the effects of surrogate vessels on the deformation patterns of a physical model of the brain under various impact conditions. Silicone gel and tubing were used as surrogates for brain tissue and blood vessels, respectively. Two aluminum cylinders representing a coronal section of the brain were constructed. One cylinder was filled with silicone gel only, and the other was filled with silicone gel and silicone tubing arranged in the radial direction in the peripheral region. An array of markers was embedded in the gel in both cylinders to facilitate strain calculation via high-speed video analysis. Both cylinders were simultaneously subjected to a combination of linear and angular acceleration using a two-segment pendulum.
Technical Paper

Geometrical and Mechanical Characterization of the Abdominal Fold of Obese Post Mortem Human Subjects for Use in Human Body Modelling

2021-04-02
2020-22-0006
Obese vehicle occupants sustain specific injury patterns in case of accidents in which the interaction between the seat belt and the abdomen may play a role. This study aimed to collect geometrical characteristics and to investigate the mechanical responses of the abdomen of obese subjects. Four Post Mortem Human Subjects (PMHS) with BMI ranging from 31 to 46 kg/m2 were collected. CT-scans performed in the seated position revealed that the antero-posterior depth of the abdominal fold (from the inguinal region to the most anterior point of the abdominal surface) was much greater (170 mm max., 127 mm average) than the thickness of subcutaneous adipose tissues (85 max., 38 mm in average). Each PMHS was subjected to three infra-injurious antero-posterior belt pulls in a seated posture with a lap belt positioned (C1) superior to the umbilicus, (C2) inferior to the umbilicus, (C3) inside the abdominal fold between the abdomen and the thigh.
Journal Article

Ligaments Laxity and Elongation at Injury in Flexed knees during Lateral Impact Conditions

2023-06-27
2022-22-0003
The knee is one of the regions of interest for pedestrian safety assessment. Past testing to study knee ligament injuries for pedestrian impact only included knees in full extension and mostly focused on global responses. As the knee flexion angle and the initial ligament laxity may affect the elongation at which ligaments fail, the objectives of this study were (1) to design an experimental protocol to assess the laxity of knee ligaments before measuring their elongation at failure, (2) to apply it in paired knee tests at two flexion angles (10 and 45 degrees). The laxity tests combined strain gauges to measure bone strains near insertions that would result from ligament forces and a custom machine to exercise the knee in all directions. Failure was assessed using a four-point bending setup with additional degrees of freedom on the axial rotation and displacement of the femur. A template was designed to ensure that the two setups used the exact same starting position.