Refine Your Search

Topic

Search Results

Standard

Off-Board Diagnostic Connector

2011-10-05
HISTORICAL
J1939/13_201110
SAE J1939-13 specifies the diagnostic connectors used for off-board connection to a vehicle’s SAE J1939 communication links. The defined diagnostic connectors support connection to the twisted shielded pair media (SAE J1939-11), the Reduced Physical Layer unshielded twisted pair (SAE J1939-15), the unshielded twisted pair of SAE J1939-14, as well as the twisted unshielded quad media (ISO 11783-2).
Standard

Physical Layer, 500 Kbps

2011-10-05
HISTORICAL
J1939/14_201110
This document defines a physical layer having a higher bandwidth capacity than other physical layers defined for SAE J1939. Newer transceiver technologies are utilized to minimize EMI. This SAE Recommended Practice is intended for light- and heavy-duty vehicles on- or off-road as well as appropriate stationary applications which use vehicle derived components (e.g., generator sets). Vehicles of interest include but are not limited to: on- and off-highway trucks and their trailers; construction equipment; and agricultural equipment and implements.
Standard

Off-Board Diagnostic Connector

2016-10-25
CURRENT
J1939/13_201610
SAE J1939-13 specifies the diagnostic connectors used for off-board connection to a vehicle’s SAE J1939 communication links. The defined diagnostic connectors support connection to the twisted shielded pair media (SAE J1939-11), the unshielded twisted pair (SAE J1939-15), the twisted pair of (SAE J1939-14), as well as the twisted unshielded quad media (ISO 11783-2).
Standard

Physical Layer, 500 kbit/s

2022-04-05
CURRENT
J1939/14_202204
This document defines a physical layer having a higher bandwidth capacity than other physical layers defined for SAE J1939. Newer transceiver technologies are utilized to minimize EMI. CAN controllers are now available which support the flexible data rate frame format. These controllers, when used on SAE J1939-14 networks, must be restricted to use only the classical frame format compliant to ISO 11898-1:2015. This SAE Recommended Practice is intended for light- and heavy-duty vehicles on- or off-road, as well as appropriate stationary applications which use vehicle derived components (e.g., generator sets). Vehicles of interest include, but are not limited to, on- and off-highway trucks and their trailers, construction equipment, and agricultural equipment and implements.
Standard

Physical Layer, 500 Kbps

2016-12-01
HISTORICAL
J1939/14_201612
This document defines a physical layer having a higher bandwidth capacity than other physical layers defined for SAE J1939. Newer transceiver technologies are utilized to minimize EMI. CAN controllers are now available which support the Flexible Data Rate Frame Format. These controllers, when used on SAE J1939-14 networks, must be restricted to use only the Classical Frame Format compliant to ISO 11898-1:2015. This SAE Recommended Practice is intended for light- and heavy-duty vehicles on- or off-road as well as appropriate stationary applications which use vehicle derived components (e.g., generator sets). Vehicles of interest include but are not limited to: on- and off-highway trucks and their trailers; construction equipment; and agricultural equipment and implements.
Standard

Physical Layer, 250 Kbps, Twisted Shielded Pair

2021-02-12
WIP
J1939/11

This document defines a physical layer having a robust immunity to EMI and physical properties suitable for harsh environments.

CAN controllers are available which support the CAN Flexible Data Rate Frame Format. These controllers, when used on SAE J1939-11 networks, must be restricted to use only the Classical Frame Format compliant to ISO 11898-1:2015.

These SAE Recommended Practices are intended for light- and heavy-duty vehicles on- or off-road as well as appropriate stationary applications which use vehicle derived components (e.g., generator sets). Vehicles of interest include but are not limited to: on- and off-highway trucks and their trailers; construction equipment; and agricultural equipment and implements.

Standard

Physical Layer, 250 Kbps, Twisted Shielded Pair

2012-09-12
HISTORICAL
J1939/11_201209
This document defines a physical layer having a robust immunity to EMI and physical properties suitable for harsh environments. These SAE Recommended Practices are intended for light- and heavy-duty vehicles on- or off-road as well as appropriate stationary applications which use vehicle derived components (e.g., generator sets). Vehicles of interest include but are not limited to: on- and off-highway trucks and their trailers; construction equipment; and agricultural equipment and implements.
Standard

Physical Layer, 250 Kbps, Twisted Shielded Pair

2016-12-06
CURRENT
J1939/11_201612
This document defines a physical layer having a robust immunity to EMI and physical properties suitable for harsh environments. CAN controllers are available which support the CAN Flexible Data Rate Frame Format. These controllers, when used on SAE J1939-11 networks, must be restricted to use only the Classical Frame Format compliant to ISO 11898-1:2015. These SAE Recommended Practices are intended for light- and heavy-duty vehicles on- or off-road as well as appropriate stationary applications which use vehicle derived components (e.g., generator sets). Vehicles of interest include but are not limited to: on- and off-highway trucks and their trailers; construction equipment; and agricultural equipment and implements.
Standard

Off-Board Diagnostic Connector

2021-02-15
WIP
J1939/13
SAE J1939-13 specifies the diagnostic connectors used for off-board connection to a vehicle’s SAE J1939 communication links. The defined diagnostic connectors support connection to the twisted shielded pair media (SAE J1939-11), the unshielded twisted pair (SAE J1939-15), the twisted pair of (SAE J1939-14), as well as the twisted unshielded quad media (ISO 11783-2).
Standard

Physical Layer, 250 Kbps, Un-Shielded Twisted Pair (UTP)

2015-08-12
HISTORICAL
J1939/15_201508
This document describes a physical layer utilizing Unshielded Twisted Pair (UTP) cable with extended stub lengths for flexibility in ECU placement and network topology. Also, connectors are not specified. CAN controllers are now available which support the newly introduced CAN Flexible Data Rate Frame format (known as “CAN FD”). These controllers, when used on SAE J1939-15 networks, must be restricted to use only the Classical Frame format compliant to ISO 11898-1 (2003). These SAE Recommended Practices are intended for light- and heavy-duty vehicles on- or off-road as well as appropriate stationary applications which use vehicle derived components (e.g., generator sets). Vehicles of interest include but are not limited to: on- and off-highway trucks and their trailers; construction equipment; and agricultural equipment and implements.
Standard

Physical Layer, 250 Kbps, Un-Shielded Twisted Pair (UTP)

2018-12-14
CURRENT
J1939/15_201812
This document describes a physical layer utilizing Unshielded Twisted Pair (UTP) cable with extended stub lengths for flexibility in ECU placement and network topology. Also, connectors are not specified. CAN controllers used on SAE J1939-15 networks must be restricted to use only Classical Frames as defined in ISO 11898- 1. A network which may have legacy controllers cannot tolerate FD Frames. These SAE Recommended Practices are intended for light- and heavy-duty vehicles on- or off-road as well as appropriate stationary applications which use vehicle derived components (e.g., generator sets). Vehicles of interest include, but are not limited to: on- and off-highway trucks and their trailers; construction equipment; and agricultural equipment and implements.
Standard

Physical Layer, 250 Kbps, Un-Shielded Twisted Pair (UTP)

2014-05-29
HISTORICAL
J1939/15_201405
This document describes a physical layer utilizing Unshielded Twisted Pair (UTP) cable with extended stub lengths for flexibility in ECU placement and network topology. Also, connectors are not specified. CAN controllers are now available which support the newly introduced CAN Flexible Data Rate Frame format (known as “CAN FD”). These controllers, when used on SAE J1939-15 networks, must be restricted to use only the Classical Frame format compliant to ISO 11989-1 (2003). These SAE Recommended Practices are intended for light- and heavy-duty vehicles on- or off-road as well as appropriate stationary applications which use vehicle derived components (e.g., generator sets). Vehicles of interest include but are not limited to: on- and off-highway trucks and their trailers; construction equipment; and agricultural equipment and implements.
Standard

Serial Control and Communications Heavy Duty Vehicle Network - Top Level Document

2013-08-14
HISTORICAL
J1939_201308
This top level document provides a general overview of the SAE J1939 network and describes the subordinate document structure. This document includes definitions of terms and abbreviations which are used among the various SAE J1939 subordinate documents. The SAE J1939DA Digital Annex spreadsheet replaces the Appendices of this document for the publication of the list of all SPN assignments, PGN assignments, NAME Function assignments, Manufacturer Code assignments, and Preferred Address assignments. This document has been updated to reflect the change to discontinue publishing the content of Table A2, Tables B1 through B12, and Table C1 in Appendix A, Appendix B, and Appendix C; instead, this content is now published in the SAE J1939DA Digital Annex spreadsheet.
Standard

SAE J1939 Functional Safety Communications Protocol

2018-11-26
HISTORICAL
J1939-76_201811
This document provides the technical requirements for implementing the SAE J1939 Functional Safety Communication Protocol in a manner determined suitable for meeting industry applicable functional safety standards.
Standard

Compliance

2015-06-04
HISTORICAL
J1939/82_201506
SAE J1939-82 Compliance describes the compliance tests and procedures to verify an SAE J1939 ECU will operate correctly on a SAE J1939 network. The purpose of these compliance procedures is to generate one or more test documents that outline the tests needed to assure that an ECU that is designed to operate as a node on a SAE J1939 network would do so correctly. SAE does not certify devices and these tests and their results do not constitute endorsement by SAE of any particular device. These tests are presented to allow testing of a device to determine self-compliance by the manufacturer of a device. The manufacturer can use its record of what procedures were run successfully to show the level of compliance with SAE J1939.
Standard

Network Management

2017-03-09
CURRENT
J1939/81_201703
SAE J1939-81 Network Management defines the processes and messages associated with managing the source addresses of applications communicating on an SAE J1939 network. Network management is concerned with the management of source addresses and the association of those addresses with an actual function and with the detection and reporting of network related errors. Due to the nature of management of source addresses, network management also specifies initialization processes, requirements for reaction to brief power outages and minimum requirements for ECUs on the network.
Standard

Network Management

2011-06-30
HISTORICAL
J1939/81_201106
SAE J1939-81 Network Management defines the processes and messages associated with managing the source addresses of applications communicating on an SAE J1939 network. Network management is concerned with the management of source addresses and the association of those addresses with an actual function and with the detection and reporting of network related errors. Due to the nature of management of source addresses, network management also specifies initialization processes, requirements for reaction to brief power outages and minimum requirements for ECUs on the network.
Standard

Network Management

2016-02-18
HISTORICAL
J1939/81_201602
SAE J1939-81 Network Management defines the processes and messages associated with managing the source addresses of applications communicating on an SAE J1939 network. Network management is concerned with the management of source addresses and the association of those addresses with an actual function and with the detection and reporting of network related errors. Due to the nature of management of source addresses, network management also specifies initialization processes, requirements for reaction to brief power outages and minimum requirements for ECUs on the network.
Standard

Network Management

2018-07-23
WIP
J1939/81
SAE J1939-81 Network Management defines the processes and messages associated with managing the source addresses of applications communicating on an SAE J1939 network. Network management is concerned with the management of source addresses and the association of those addresses with an actual function and with the detection and reporting of network related errors. Due to the nature of management of source addresses, network management also specifies initialization processes, requirements for reaction to brief power outages and minimum requirements for ECUs on the network.
X