Technical Paper
Single Bed, Three Way Catalyst in the European Environment
1985-10-01
852096
The performance of a vehicle equipped with a single bed three way catalyst has been monitored during a 50,000 mile durability test at maximum speed (168 ktnph). Subsequently, emissions as a function of average speed were studied in baseline, durability catalyst and dynamometer aged catalyst conditions.