Journal Article
Biomechanical Responses of the THOR-AV ATD in Rear Facing Test Conditions
2022-03-29
2022-01-0836
The THOR-AV dummy is a modified THOR dummy being developed for occupant safety testing in upright and reclined seating postures. The dummy has a new neck with improved biofidelity in rear impact, a pelvis/abdomen/lumbar design to improve seating posture, and a pelvis anthropometry that mimics human submarining responses for reclined seat testing. The dummy was evaluated against postmortem human subject (PMHS) corridors in rearward facing impact conditions (56 km/h impact speed, 38g acceleration) in both 25° and 45° seatback configurations. Biofidelity Ranking System (BRS) scores were calculated in accordance with NHTSA’s latest calculation algorithm. The BRS scores for THOR-AV seat loading are 1.58 (“good” biofidelity) and 2.94 (“marginal” biofidelity) for the 25° and 45° configurations respectively. The BRS scores for THOR-AV occupant responses are 1.95 and 1.38 for the 25° and 45° configurations respectively, both corresponding to “good” biofidelity.