Refine Your Search

Search Results

Viewing 1 to 5 of 5
Technical Paper

A DFSS Approach to Optimize the Second Row Floor Duct Using Parametric Modelling

2017-03-28
2017-01-0176
The main function of mobile air conditioning system in a vehicle is to provide the thermal comfort to the occupants sitting inside the vehicle at all environmental conditions. The function of ducts is to get the sufficient airflow from the HVAC system and distribute the airflow evenly throughout the cabin. In this paper, the focus is to optimize the rear passenger floor duct system to meet the target requirements through design for six sigma (DFSS) methodology. Computational fluid dynamics analysis (CFD) has been used extensively to optimize system performance and shorten the product development time. In this methodology, a parametric modeling of floor duct design using the factors such as crossectional area, duct length, insulation type, insulation thickness and thickness of duct were created using CATIA. L12 orthogonal design array matrix has been created and the 3D CFD analysis has been carried out individually to check the velocity and temperature.
Technical Paper

HVAC Defrost System Assessment through 1D and 3D Simulation during Concept Development

2019-04-02
2019-01-0911
The windshield defrosting performance is a very important requirement for the vehicle safety because it affects directly the driver’s visibility during driving. The defrosting process in the vehicle is carried out by blowing hot air from the HVAC (Heating Ventilation and Air conditioning) through the defrost duct system. Computational Fluid Dynamics (CFD) is used to numerically simulate the vehicle defroster performance with the available defrost duct outlet temperature and coolant temperature data from the vehicle testing. This paper describes the 1D modelling of complete HVAC system configuration to find out the defrost duct outlet temperature and through the CFD, transient defrost simulation was carried out to simulate the ice melting process over the windshield at various time step. In the CFD simulation, shell modelling analysis method is followed to predict the de-icing phenomenon over the vehicle windshield.
Technical Paper

Optimization of Center Console Duct Using Robust Assessment Methodology

2018-04-03
2018-01-0072
The thermal comfort for the passenger inside the cabin is maintained by the HVAC system. To ensure a comfort for the 2nd row passengers in the cabin, it is very essential to design an efficient HVAC and rear console duct system which can deliver sufficient airflow with less pressure drop. The primary focus of the study is to assess existing airflow of the center console duct using CFD and propose improvement in its duct shape to meet the passenger comfort sitting in the rear seat. In this study, the vehicle cabin model, HVAC system and duct design was modeled using the design software UG. To analyze and estimate the behavior of the air flow of the system, a steady state simulation was performed using STAR CCM CFD software. The performance of the console duct system is judged by parameters like distribution of airflow, velocity at console duct outlet, pressure drop through the duct and the uniformity of the air flow at the passenger locations.
Technical Paper

Optimization of MAC Side Window Demister Outlet by Parametric Modelling through DFSS Approach

2015-04-14
2015-01-0363
In recent years clearing the mist on side windows is one of the main criterions for all OEMs for providing comfort level to the person while driving. Visibility through the side windows will be poor when the mist is not cleared to the desired level. “Windows fog up excessively/don't clear quickly” is one of the JD Power question to assess the customer satisfaction related to HVAC performance. In a Mobile Air Conditioning System, HVAC demister duct and outlet plays an important role for removing the mist formation on vehicle side window. Normally demister duct and outlet design is evaluated by the target airflow and velocity achieved at driver and passenger side window. The methodology for optimizing the demister outlet located at side door trim has been discussed. Detailed studies are carried out for creating a parametric modeling and optimization of demister outlet design for meeting the target velocity.
Technical Paper

Studies on Aero-Acoustics Noise Prediction of MAC Unit Using Computational Modelling

2016-04-05
2016-01-0218
In an automotive air conditioning, aero-acoustic noise originating from HVAC (Heating Ventilation and Air Conditioning) unit is one of the major concerns for the customer satisfaction. “Fan blower excessive noise” is one among the top issues for all automotive manufacturers. In this paper, a 3D computational analysis is carried out for a passenger car HVAC unit to predict the noise originated from the HVAC unit. HVAC modeling is done using uni graphics and ANSA and the analysis is carried out using the commercial CFD software STAR CCM+. The inputs for the analysis are the airflow at HVAC Inlet, blower speed and the pressure drop characteristics of evaporator, filter and heater core. The computational model is done by considering the blower region as MRF (Moving Reference Frame) and the air flow is considered incompressible. DES (Detached Eddy Simulation) model is used to resolve the eddies generated by the turbulent flow.
X