Technical Paper
Human Cervical Motion Segment Flexibility and Facet Capsular Ligament Strain Under Combined Posterior Shear, Extension and Axial Compression
2000-11-01
2000-01-SC12
The cervical facet capsular ligaments are thought to be an important anatomical site of whiplash injury, although the mechanism by which these structures may be injured during whiplash remains unclear. The purpose of this study was to quantify the intervertebral flexibility and maximum principal strain in the facet capsular ligament under combined shear, bending and compressive loads similar to those which occur during whiplash loading. Two motion segments (C3-4 and C5-6) from seven female donors (50 ± P 10 years) were exposed to quasi-static posterior shear loads of 135 N applied to the superior vertebra on four occasions while under compressive axial preloads of 0 N, 45 N, 197 N and 325 N. Vertebral body motions and the full Lagrangian strain field in the right facet capsular ligament were measured using stereophotogrammetry. After flexibility testing, the right facet joint of each motion segment was isolated and failed in posterior shear.