Technical Paper
Engine Demonstration of Microwave Assisted Particulate Trap Regeneration
2005-05-11
2005-01-2141
In this study a microwave assisted particulate trap regeneration system has been developed. Microwave technology typically shows uneven temperature distribution in a trap. In this research an innovative technique is introduced: a so-called circular polarizer for generating a more even energy distribution in the trap. Experimental work has been performed on a 1.2 l TDI engine on an engine dynamometer. A cordierite wall-flow trap was located in the exhaust pipe. Experiments have been performed with variation of temperature at the start of regeneration, energy input duration and external combustion air flow. It has been observed that the exhaust gas flow of the engine, even at idle, is too high for maintaining propagating flame fronts. It can be concluded that microwave regeneration with a low-power microwave generator of about 1 kW must be applied in a multiple branch trap system or regeneration events must be applied in periods when the engine is not running.