Refine Your Search

Topic

Author

Search Results

Standard

ACCESS SYSTEMS FOR CONSTRUCTION AND INDUSTRIAL EQUIPMENT

1970-07-01
HISTORICAL
J185_197007
This recommended practice covers the criteria for steps, ladders, walkways, platforms, grab rails (handrails), grab irons, guardrails, and entrance openings as they relate to aiding the operator and/or servicemen in performing their functions on the vehicle.
Standard

AUTOMOTIVE PIPE FITTINGS

1993-06-01
HISTORICAL
J530_199306
This SAE Standard includes complete general and dimensional specifications for those types of pipe fittings commonly used in the automotive and other mass production industries where the use of lubricants or sealers is objectionable. The automotive pipe fittings shown in Figures 1 to 17 and Tables 1 to 6 are intended for general automotive and similar applications involving low or medium pressures or in conjunction with automotive tube fittings in piping systems.
Standard

AUTOMOTIVE PIPE FITTINGS

1992-06-01
HISTORICAL
J530_199206
This SAE Standard includes complete general and dimensional specifications for those types of pipe fittings commonly used in the automotive and other mass production industries where the use of lubricants or sealers is objectionable. The automotive pipe fittings shown in Figures 1 to 17 and Tables 1 to 6 are intended for general automotive and similar applications involving low or medium pressures or in conjunction with automotive tube fittings in piping systems.
Standard

AUTOMOTIVE PIPE FITTINGS

1981-01-01
HISTORICAL
J530_198101
This standard includes complete general and dimensional specifications for those types of pipe fittings commonly used in the automotive and other mass production industries where the use of lubricants or sealers is objectionable. The automotive pipe fittings shown in Figs. 1-17 and Tables 2-7 are intended for general automotive and similar applications involving low or medium pressures or in conjunction with automotive tube fittings in piping systems.
Standard

AUTOMOTIVE PIPE FITTINGS

1994-05-01
HISTORICAL
J530_199405
This SAE Standard includes complete general and dimensional specifications for those types of pipe fittings commonly used in the automotive and other mass production industries where the use of lubricants or sealers is objectionable. The automotive pipe fittings shown in Figures 1 to 17 and Tables 1 to 6 are intended for general automotive and similar applications involving low or medium pressures or in conjunction with automotive tube fittings in piping systems.
Standard

AUTOMOTIVE PIPE, FILLER, AND DRAIN PLUGS

1992-02-01
HISTORICAL
J531_199202
This SAE Standard includes complete general and dimensional specifications for those types of pipe, filler, and drain plugs (shown in Figures 1 to 6 and Tables 1 to 4) commonly used in automotive and related industrial applications.
Standard

AUTOMOTIVE PIPE, FILLER, AND DRAIN PLUGS

1981-01-01
HISTORICAL
J531_198101
This standard includes complete general and dimensional specifications for those types of pipe, filler, and drain plugs (shown in Figs. 1-6 and Tables 2-4) commonly used in automotive and related industrial applications.
Standard

AUTOMOTIVE PIPE, FILLER, AND DRAIN PLUGS

1994-06-01
HISTORICAL
J531_199406
This SAE Standard includes complete general and dimensional specifications for those types of pipe, filler, and drain plugs (shown in Figures 1 to 6 and Tables 1 to 4) commonly used in automotive and related industrial applications.
Standard

AUTOMOTIVE TUBE FITTINGS

1975-12-01
HISTORICAL
J512J_197512
This standard covers complete general and dimensional specifications for the various types of tube fittings intended for general application in the automotive, appliance, and allied fields. Flare type fittings shall be as specified in Figs. 1-4 and Tables 1-3. NOTE: For sizes 3/16-3/8 and 1/2-3/4 the flare type fittings depicted in Figs. 1A-3C are identical with the corresponding refrigeration tube fittings specified in SAE J513. Special size combination fittings 3/16-3/8 and 1/2-3/4 shall be as specified in J513. Inverted flared type fittings shall be as specified in Figs. 5-11 and Tables 1, 4-7. Gages and gaging procedures pertaining to inverted flared tube fittings are given in Appendix A. NOTE: The seat dimensions specified in Table 4 are predicated on practical threading limitations in steel fittings and use of these fittings with double flared tubing.
Standard

Air Brake Valve - Performance Requirements

2020-12-18
CURRENT
J1410_202012
This SAE Recommended Practice establishes minimum performance requirements for new pneumatic valves when tested in accordance with the test procedure outlined in SAE J1409. The performance requirements will include: a Input-output performance b Leakage characteristics c Low temperature performance d Elevated temperature performance e Corrosion resistance performance f Endurance testing g Structural integrity
Standard

Air Brake Valve - Performance Requirements

2016-07-20
HISTORICAL
J1410_201607
This SAE Recommended Practice establishes minimum performance requirements for new pneumatic valves when tested in accordance with the test procedure outlined in SAE J1409. The performance requirements will include: a Input-output performance b Leakage characteristics c Low temperature performance d Elevated temperature performance e Corrosion resistance performance f Endurance testing g Structural integrity
Standard

Air Brake Valve Input-Output Characteristic Requirements

2016-06-17
CURRENT
J1861_201606
This SAE Recommended Practice establishes minimum tolerance requirements for pilot operated and mechanically actuated modulating type valves, and through type valves used in the service brake control system when tested in accordance with the test procedure outlined in SAE J1859. This document applies to the nominal input-output characteristics as specified by vehicle original equipment manufacturer and labeled by the valve manufacturer as outlined in SAE J1860. The tolerance requirements will include: a Crack (opening) pressure or force. Crack pressure may be measured at the initial output pressure or as the pressure differential before output pressure exceeds 14 kPa (2 psi). Crack force may be measured at initial output pressure or before output pressure exceeds 14 kPa (2 psi). b Pressure differential (input-output)
Standard

Air Brake Valve Input-Output Characteristic Requirements

2011-09-12
HISTORICAL
J1861_201109
This SAE Recommended Practice establishes minimum tolerance requirements for pilot operated and mechanically actuated modulating type valves, and through type valves used in the service brake control system when tested in accordance with the test procedure outlined in SAE J1859. This document applies to the nominal input-output characteristics as specified by vehicle original equipment manufacturer and labeled by the valve manufacturer as outlined in SAE J1860. The tolerance requirements will include: a Crack (opening) pressure or force. Crack pressure may be measured at the initial output pressure or as the pressure differential before output pressure exceeds 14 kPa (2 psi). Crack force may be measured at initial output pressure or before output pressure exceeds 14 kPa (2 psi). b Pressure differential (input-output)
Standard

Automobile and Motor Coach Wiring

2016-04-13
CURRENT
J1292_201604
This SAE Recommended Practice covers the application of primary wiring distribution system harnesses to automotive, and Motor Coach vehicles. This is written principally for new vehicles but is also applicable to rewiring and service. It covers the areas of performance, operating integrity, efficiency, economy, uniformity, facility of manufacturing and service. This practice applies to wiring systems of less than 50 V.
Standard

Automotive Tube Fittings

2022-03-31
CURRENT
J512_202203
This SAE Standard covers complete general and dimensional specifications for the various types of tube fittings intended for general application in the automotive, appliance, and allied fields. See SAE J1131 for the performance requirements of reusable (push to connect) fittings intended for use in automotive air brake systems. Flare type fittings shall be as specified in Figures 1 to 4 and Tables 3 to 5. NOTE—For sizes 3/16 to 3/8 and 1/2 to 3/4 the flare type fittings depicted in Figures 1A to 3C are identical with the corresponding refrigeration tube fittings specified in SAE J513. Special size combination fittings 3/16 to 3/8 and 1/2 to 3/4 shall be as specified in SAE J513. Inverted flared type fittings shall be as specified in Figures 5 to 11 and Tables 3, 6, 7, 8, and 9. Gages and gaging procedures pertaining to inverted flared tube fittings are given in Appendix A.
Standard

Automotive Tube Fittings

2017-05-30
HISTORICAL
J512_201705
This SAE Standard covers complete general and dimensional specifications for the various types of tube fittings intended for general application in the automotive, appliance, and allied fields. See SAE J1131 for the performance requirements of reusable (push to connect) fittings intended for use in automotive air brake systems. Flare type fittings shall be as specified in Figures 1 to 4 and Tables 3 to 5. NOTE—For sizes 3/16 to 3/8 and 1/2 to 3/4 the flare type fittings depicted in Figures 1A to 3C are identical with the corresponding refrigeration tube fittings specified in SAE J513. Special size combination fittings 3/16 to 3/8 and 1/2 to 3/4 shall be as specified in SAE J513. Inverted flared type fittings shall be as specified in Figures 5 to 11 and Tables 3, 6, 7, 8, and 9. Gages and gaging procedures pertaining to inverted flared tube fittings are given in Appendix A.
X