Refine Your Search

Topic

Author

Search Results

Standard

ASSESSING CLEANLINESS OF HYDRAULIC FLUID POWER COMPONENTS AND SYSTEMS

1979-06-01
HISTORICAL
J1227_197906
To describe laboratory methods for determining and reporting the contaminant level of the wetted portion of hydraulic fluid power components, parts, subsystems and systems, and of fill fluids. For each type of item it provides a method of obtaining the liquid sample and the contamination level thereof. It also includes procedures for establishing a sampling plan and guidelines for establishing levels of acceptance, but does not set those levels.
Standard

ASSESSING CLEANLINESS OF HYDRAULIC FLUID POWER COMPONENTS AND SYSTEMS

1986-03-01
HISTORICAL
J1227_198603
To describe laboratory methods for determining and reporting the contaminant level of the wetted portion of hydraulic fluid power components, parts, subsystems and systems, and of fill fluids. For each type of item it provides a method of obtaining the liquid sample and the contamination level thereof. It also includes procedures for establishing a sampling plan and guidelines for establishing levels of acceptace, but does not set those levels.
Standard

AUTOMOTIVE PIPE, FILLER, AND DRAIN PLUGS

1992-02-01
HISTORICAL
J531_199202
This SAE Standard includes complete general and dimensional specifications for those types of pipe, filler, and drain plugs (shown in Figures 1 to 6 and Tables 1 to 4) commonly used in automotive and related industrial applications.
Standard

AUTOMOTIVE PIPE, FILLER, AND DRAIN PLUGS

1981-01-01
HISTORICAL
J531_198101
This standard includes complete general and dimensional specifications for those types of pipe, filler, and drain plugs (shown in Figs. 1-6 and Tables 2-4) commonly used in automotive and related industrial applications.
Standard

AUTOMOTIVE PIPE, FILLER, AND DRAIN PLUGS

1994-06-01
HISTORICAL
J531_199406
This SAE Standard includes complete general and dimensional specifications for those types of pipe, filler, and drain plugs (shown in Figures 1 to 6 and Tables 1 to 4) commonly used in automotive and related industrial applications.
Standard

AUTOMOTIVE TUBE FITTINGS

1975-12-01
HISTORICAL
J512J_197512
This standard covers complete general and dimensional specifications for the various types of tube fittings intended for general application in the automotive, appliance, and allied fields. Flare type fittings shall be as specified in Figs. 1-4 and Tables 1-3. NOTE: For sizes 3/16-3/8 and 1/2-3/4 the flare type fittings depicted in Figs. 1A-3C are identical with the corresponding refrigeration tube fittings specified in SAE J513. Special size combination fittings 3/16-3/8 and 1/2-3/4 shall be as specified in J513. Inverted flared type fittings shall be as specified in Figs. 5-11 and Tables 1, 4-7. Gages and gaging procedures pertaining to inverted flared tube fittings are given in Appendix A. NOTE: The seat dimensions specified in Table 4 are predicated on practical threading limitations in steel fittings and use of these fittings with double flared tubing.
Standard

Air Brake Valve - Performance Requirements

2020-12-18
CURRENT
J1410_202012
This SAE Recommended Practice establishes minimum performance requirements for new pneumatic valves when tested in accordance with the test procedure outlined in SAE J1409. The performance requirements will include: a Input-output performance b Leakage characteristics c Low temperature performance d Elevated temperature performance e Corrosion resistance performance f Endurance testing g Structural integrity
Standard

Air Brake Valve - Performance Requirements

2016-07-20
HISTORICAL
J1410_201607
This SAE Recommended Practice establishes minimum performance requirements for new pneumatic valves when tested in accordance with the test procedure outlined in SAE J1409. The performance requirements will include: a Input-output performance b Leakage characteristics c Low temperature performance d Elevated temperature performance e Corrosion resistance performance f Endurance testing g Structural integrity
Standard

Air Brake Valve Input-Output Characteristic Requirements

2016-06-17
CURRENT
J1861_201606
This SAE Recommended Practice establishes minimum tolerance requirements for pilot operated and mechanically actuated modulating type valves, and through type valves used in the service brake control system when tested in accordance with the test procedure outlined in SAE J1859. This document applies to the nominal input-output characteristics as specified by vehicle original equipment manufacturer and labeled by the valve manufacturer as outlined in SAE J1860. The tolerance requirements will include: a Crack (opening) pressure or force. Crack pressure may be measured at the initial output pressure or as the pressure differential before output pressure exceeds 14 kPa (2 psi). Crack force may be measured at initial output pressure or before output pressure exceeds 14 kPa (2 psi). b Pressure differential (input-output)
Standard

Air Brake Valve Input-Output Characteristic Requirements

2011-09-12
HISTORICAL
J1861_201109
This SAE Recommended Practice establishes minimum tolerance requirements for pilot operated and mechanically actuated modulating type valves, and through type valves used in the service brake control system when tested in accordance with the test procedure outlined in SAE J1859. This document applies to the nominal input-output characteristics as specified by vehicle original equipment manufacturer and labeled by the valve manufacturer as outlined in SAE J1860. The tolerance requirements will include: a Crack (opening) pressure or force. Crack pressure may be measured at the initial output pressure or as the pressure differential before output pressure exceeds 14 kPa (2 psi). Crack force may be measured at initial output pressure or before output pressure exceeds 14 kPa (2 psi). b Pressure differential (input-output)
Standard

Automotive Tube Fittings

2022-03-31
CURRENT
J512_202203
This SAE Standard covers complete general and dimensional specifications for the various types of tube fittings intended for general application in the automotive, appliance, and allied fields. See SAE J1131 for the performance requirements of reusable (push to connect) fittings intended for use in automotive air brake systems. Flare type fittings shall be as specified in Figures 1 to 4 and Tables 3 to 5. NOTE—For sizes 3/16 to 3/8 and 1/2 to 3/4 the flare type fittings depicted in Figures 1A to 3C are identical with the corresponding refrigeration tube fittings specified in SAE J513. Special size combination fittings 3/16 to 3/8 and 1/2 to 3/4 shall be as specified in SAE J513. Inverted flared type fittings shall be as specified in Figures 5 to 11 and Tables 3, 6, 7, 8, and 9. Gages and gaging procedures pertaining to inverted flared tube fittings are given in Appendix A.
Standard

Beaded Ends for Hose Connections and Hose Fittings

2021-09-14
WIP
J1231

This SAE Standard provides general and dimensional specifications for beaded ends and hose fittings. These connections are intended for general applications in low pressure automotive and hydraulic systems on automotive, industrial, and commercial products. The fittings shown are designed to be used with hoses that are intended to be retained by hose clamps.

It is recommended that where step sizes or additional types of fittings are required, they be designed to conform with the specifications of this document insofar as they may apply. The following general specifications shall supplement the dimensional data contained in the tables with respect to all unspecified detail.

Standard

Beaded Ends for Hose Connections and Hose Fittings

2021-04-22
CURRENT
J1231_202104
This SAE Standard provides general and dimensional specifications for beaded ends and hose fittings. These connections are intended for general applications in low pressure automotive and hydraulic systems on automotive, industrial, and commercial products. The fittings shown are designed to be used with hoses that are intended to be retained by hose clamps. It is recommended that where step sizes or additional types of fittings are required, they be designed to conform with the specifications of this document insofar as they may apply. The following general specifications shall supplement the dimensional data contained in the tables with respect to all unspecified detail.
Standard

Brake Force Distribution Field Test Procedure for Truck and Bus

2003-04-29
HISTORICAL
J225_200304
This SAE Recommended Practice provides a field test procedure and instructions for: a Instrumentation and Equipment b Vehicle Preparation c Test of air-braked single and combination vehicles d Calculation of brake force distribution e This test procedure is intended to be used as a field procedure. If a more refined method, utilizing laboratory equipment, is required, refer to SAE J1505.
Standard

CAPACITY RATING—ELEVATING SCRAPERS

1993-06-01
HISTORICAL
J957_199306
This SAE Standard specifies a procedure for approximating the volume of a typical material carried in the bowl of an elevating scraper as defined in SAE J728 and SAE J1057. The volumes are based on the inside dimensions of the bowl and a representative volume on top of the bowl. This rating method is intended to provide a consistent means of comparing capacities; it is not intended to define actual capacities that might be observed in any specific application.
X