Browse Standards ARP4553A
Historical REVISED 2008-12-19

Aerospace - Accumulator, Hydraulic, Self-Displacing ARP4553A

This SAE Aerospace Recommended Practice (ARP) is intended to provide design and qualification requirements for self-displacing hydraulic accumulators.
These requirements are intended be included in the Procurement Specification for the accumulator. Those requirements identified by the use of “shall” are considered to be essential requirements; those requirements identified by the use of “should” are considered to be optional requirements for inclusion in the Specification at the discretion of the Purchaser.
In addition, test methods for production acceptance and qualification purposes are provided.
The accumulator is intended for use in military aerospace hydraulic systems with rated pressures of up to 8000 psi (55 158 kPa) and of the following types as specified in AS5440:
  1. a
    Type I −65 to +160 °F (−54 to +71 °C) fluid temperature
  2. b
    Type II −65 to +275 °F (−54 to +135 °C) fluid temperature
The accumulator is also intended for use in commercial aerospace and helicopter hydraulic systems.
ARP4553B
2018-09-04
Latest
Revised
ARP4553A
2008-12-19
Historical
Revised
ARP4553
2002-07-16
Historical
Reaffirmed

SAE MOBILUS

Subscribers can view annotate, and download all of SAE's content. Learn More »

Access SAE MOBILUS »

Members save up to 10% off list price.
Login to see discount.
Special Offer: AeroPaks offers a customized subscription plan that is cost-effective and allows you to choose the number of downloads and Aerospace and Aerospace Material documents you need. Find more information here.
We also recommend:
STANDARD

PHOSPHATE ESTER AIRCRAFT HYDRAULIC FLUID CONTAMINATION WITH CHLORINE CONTAINING COMPOUNDS

AIR1416

View Details

STANDARD

Accumulator, Hydraulic, Welded Bellows, Factory Pre-Charged

ARP4378C

View Details

STANDARD

Recommended Design and Test Requirements for Hydraulic Thermal Expansion Relief Valves

ARP4835A

View Details

Get Involved

Want to participate in updating this standard?

X