Technical Paper
Thermal Management Development for a Dedicated Hybrid Engine
2024-04-09
2024-01-2416
The high-efficiency dedicated hybrid engine (DHE) has led to increasingly complex challenges in engine thermal management. On one hand, the high compression ratio of up to 16:1 makes the engine more susceptible to knocking, necessitating meticulous thermal management to mitigate the potential sensitivity to metal temperature. On the other hand, extensive use of external cooled exhaust gas recirculation (EGR) helps reduce knocking and improve thermal efficiency, but it also raises temperature levels and requires additional cooling measures. For the 1.5L DHE developed by SAIC Motor, a split cooling structure was employed in the engine cooling system design, with the cylinder head water jacket and cylinder block water jacket arranged in parallel and equipped with different coolant outlets. By utilizing a dual thermostat to control flow, this design allows for adjustable flow distribution, providing effective cooling to the cylinder head while reducing cooling to the cylinder block.