ISS IATCS Coolant Loop Biocide Implementation

2008-06-29
2008-01-2159
The proliferation and growth of microorganisms in the Internal Active Thermal Control System (IATCS) aboard the International Space Station (ISS) has been of significant concern since 2001. Initial testing and assessments of biocides to determine bacterial disinfection capability, material compatibility, stability (rate of oxidative degradation and identification of degradation products), solubility, application methodology, impact on coolant toxicity hazard level, and impact on environmental control and life support systems identified a prioritized list of acceptable biocidal agents including glutaraldehyde, ortho-phthalaldehyde (OPA), and methyl isothiazolone. Glutaraldehyde at greater than 25 ppm was eliminated due to NASA concerns with safety and toxicity and methyl isothiazolone was eliminated from further consideration due to ineffectiveness against biofilms and toxicity at higher concentrations.
Technical Paper

Status of the Orion Environmental Control and Life Support Architecture

2008-06-29
2008-01-2085
In 2007, the architecture of the Orion Environmental Control and Life Support System went through a major reassessment driven by overall vehicle weight considerations. The changes were initiated with the challenge to switch from a two fault tolerant based configuration to one that is one fault tolerant. This paper describes this design evolution.
Technical Paper

Rotary Drum Separator and Pump for the Sabatier Carbon Dioxide Reduction System

2005-07-11
2005-01-2863
A trade study conducted in 2001 selected a rotary disk separator as the best candidate to meet the requirements for an International Space Station (ISS) Carbon Dioxide Reduction Assembly (CRA). The selected technology must provide micro-gravity gas/liquid separation and pump the liquid from 69 kPa (10 psia) at the gas/liquid interface to 124 kPa (18 psia) at the wastewater bus storage tank. The rotary disk concept, which has pedigree in other systems currently being built for installation on the ISS, failed to achieve the required pumping head within the allotted power. The separator discussed in this paper is a new design that was tested to determine compliance with performance requirements in the CRA. The drum separator and pump (DSP) design is similar to the Oxygen Generator Assembly (OGA) Rotary Separator Accumulator (RSA) in that it has a rotating assembly inside a stationary housing driven by a integral internal motor[1].
Technical Paper

Assessment of Technology Readiness Level of a Carbon Dioxide Reduction Assembly (CRA) for Use on International Space Station

2004-07-19
2004-01-2446
When technologies are traded for incorporation into vehicle systems to support a specific mission scenario, they are often assessed in terms of “Technology Readiness Level” (TRL). TRL is based on three major categories of Core Technology Components, Ancillary Hardware and System Maturity, and Control and Control Integration. This paper describes the Technology Readiness Level assessment of the Carbon Dioxide Reduction Assembly (CRA) for use on the International Space Station. A team comprising of the NASA Johnson Space Center, Marshall Space Flight Center, Southwest Research Institute and Hamilton Sundstrand Space Systems International have been working on various aspects of the CRA to bring its TRL from 4/5 up to 6. This paper describes the work currently being done in the three major categories. Specific details are given on technology development of the Core Technology Components including the reactor, phase separator and CO2 compressor.
Technical Paper

The Development of the Vapor Phase Catalytic Ammonia Removal (VPCAR) Engineering Development Unit

2004-07-19
2004-01-2495
This paper presents the results of a program to develop the next generation Vapor Phase Catalytic Ammonia Removal (VPCAR) system. VPCAR is a spacecraft water recycling system designed by NASA and constructed by Water Reuse Technology Inc. The technology has been identified by NASA to be the next generation water recycling system [1]. It is designed specifically for a Mars transit vehicle mission. This paper provides a description of the process and an evaluation of the performance of the new system. The equivalent system mass (ESM) is calculated and compared to the existing state-of-the art. A description of the contracting mechanism used to construct the new system is also provided.
Technical Paper

Selection of an Alternate Biocide for the ISS Internal Thermal Control System Coolant - Phase II

2004-07-19
2004-01-2472
The ISS (International Space Station) ITCS (Internal Thermal Control System) includes two internal coolant loops that utilize an aqueous based coolant for heat transfer. A silver salt biocide had previously been utilized as an additive in the coolant formulation to control the growth and proliferation of microorganisms within the coolant loops. Ground-based and in-flight testing demonstrated that the silver salt was rapidly depleted, and did not act as an effective long-term biocide. Efforts to select an optimal alternate biocide for the ITCS coolant application have been underway and are now in the final stages. An extensive evaluation of biocides was conducted to down-select to several candidates for test trials and was reported on previously.
Technical Paper

Liquid Cooling Garment Adaptation to Enhance Surgical Outcomes

2003-07-07
2003-01-2339
Hypothermia is a well documented problem for surgical patients and is historically addressed by the use of a variety of warming aids and devices applied to the patient before, during, and after surgery. Their effectiveness is limited in many surgeries by practical constraints of surgical access, and hypothermia remains a significant concern. Increasing the temperature of the operating room has been proposed as an alternative solution. However, operating room temperatures must be cool enough to limit thermal stress on the surgical team despite the heat transport barriers imposed by protective sterile garments. Space technology in the form of the liquid cooling garment worn by EVA astronauts answers this need. Hamilton Sundstrand Space Systems International (HSSSI) has been working with Hartford Hospital to adapt liquid cooling garment technology for use by surgical teams in order to allow them to work comfortably in warmer operating room environments.
Technical Paper

Requirements and Potential for Enhanced EVA Information Interfaces

2003-07-07
2003-01-2413
NASA has long recognized the advantages of providing improved information interfaces to EVA astronauts and has pursued this goal through a number of development programs over the past decade. None of these activities or parallel efforts in industry and academia has so far resulted in the development of an operational system to replace or augment the current extravehicular mobility unit (EMU) Display and Controls Module (DCM) display and cuff checklist. Recent advances in display, communications, and information processing technologies offer exciting new opportunities for EVA information interfaces that can better serve the needs of a variety of NASA missions. Hamilton Sundstrand Space Systems International (HSSSI) has been collaborating with Simon Fraser University and others on the NASA Haughton Mars Project and with researchers at the Massachusetts Institute of Technology (MIT), Boeing, and Symbol Technologies in investigating these possibilities.
Technical Paper

Chameleon Suit – A Different Paradigm for Future EVA Systems

2003-07-07
2003-01-2445
The demands of future NASA exploration and scientific missions in space force the reevaluation of some of the basic assumptions and approaches that underlie current extravehicular activity (EVA) systems. Developing designs that can simultaneously achieve the advanced capabilities and the reductions in system mass and mission expendables targeted by NASA has proven to be a formidable challenge. The constraints of human needs, space environments, and current EVA system architectures demand technical capabilities beyond current expectations to achieve system goals. Under NASA Institute for Advanced Concepts (NIAC) sponsorship, Hamilton Sundstrand has been studying a new system paradigm to achieve the EVA system goals. The Chameleon Suit concept employs an active pressure suit that directly interacts between human systems and space environments.
Technical Paper

Performance Characteristics of a High Intensity Cryogenic Flow Boiler

2003-07-07
2003-01-2507
Hamilton Sundstrand has been working on the development of a new cryogenic flow boiler based on its patented compact, high-intensity cooler (CHIC) technology intended to provide low weight and volume and overcome freezing problems associated with cryogen use in EVA spacesuit cooling. Tests of the prototype device resulting from that effort have now been completed. The test data demonstrate that the design is extremely resistant to freezing the heat transport fluid as anticipated. Highly effective heat transfer is achieved in a compact device combining the functions of several conventional heat exchangers. This novel heat exchanger, a “normal flow” layered impingement arrangement should provide a very compact solution to any heat transfer applications where the cold fluid operates below the warm fluid's freezing point. Test results are generally consistent with design analyses for the prototype.
Technical Paper

Testing and Development of New Catalysts for Vapor Phase Ammonia Oxidation

2003-07-07
2003-01-2502
Catalytic oxidation is an effective means of controlling the build up of ammonia and other trace gas contaminants within closed spaces. However, it sometimes leads to the formation of noxious gases that need to be removed in post-treatment systems. In addition, ammonia removal is an issue when regeneration of water from wastewater is considered since ammonia is a byproduct of urea decomposition. For example, the VPCAR (Vapor Phase Catalytic Ammonia Reduction) advanced water processor system includes an oxidation reactor for the destruction of ammonia and of other volatile organics that are not separated out in the evaporator due to their volatility. The oxidation of ammonia may produce nitrogen, nitrogen oxides (NO and NO2), nitrous oxide (N2O) and water vapor. The Spacecraft Maximum Allowable Concentration (SMAC) for NO and NO2 are respectively 4.5 and 0.5 ppm whereas the Threshold Limit Value (TLV) for N2O is 25 ppm.
Technical Paper

Selection of an Alternate Biocide for the International Space Station Internal Active Thermal Control System Coolant Loops

2003-07-07
2003-01-2568
The International Space Station (ISS) IATCS (Internal Active Thermal Control System) includes two internal coolant loops that use an aqueous based coolant for heat transfer. A silver salt biocide was used initially as an additive in the coolant formulation to control the growth and proliferation of microorganisms in the coolant loops. Ground-based and in-flight testing has demonstrated that the silver salt is rapidly depleted and not effective as a long-term biocide. Efforts are now underway to select an alternate biocide for the IATCS coolant loop with greatly improved performance. An extensive evaluation of biocides was conducted to select several candidates for test trials.
Technical Paper

Development Status of the VPCAR Water Processor Assembly

2003-07-07
2003-01-2626
The purification of waste water is a critical element of any long-duration space mission. The Vapor Phase Catalytic Ammonia Removal (VPCAR) system offers the promise of a technology requiring low quantities of expendable material that is suitable for exploration missions. NASA has funded an effort to produce an engineering development unit specifically targeted for integration into the NASA Johnson Space Center's Integrated Human Exploration Mission Simulation Facility (INTEGRITY) formally known in part as the Bioregenerative Planetary Life Support Test Complex (Bio-Plex) and the Advanced Water Recovery System Development Facility. The system includes a Wiped-Film Rotating-Disk (WFRD) evaporator redesigned with micro-gravity operation enhancements, which evaporates wastewater and produces water vapor with only volatile components as contaminants. Volatile contaminants, including organics and ammonia, are oxidized in a catalytic reactor while they are in the vapor phase.
Technical Paper

Performance of WPA Conductivity Sensor During Two-Phase Fluid Flow in Microgravity

2003-07-07
2003-01-2693
The Conductivity Sensor designed for use in the Node 3 Water Processor Assembly (WPA) was based on the existing Space Shuttle application for the fuel cell water system. However, engineering analysis has determined that this sensor design is potentially sensitive to two- phase fluid flow (gas/liquid) in microgravity. The source for this sensitivity is the fact that free gas will become lodged between the sensor probe and the wall of the housing without the aid of buoyancy in 1-g. Once gas becomes lodged in the housing, the measured conductivity will be offset based on the volume of occluded gas. A development conductivity sensor was flown on the NASA Microgravity Plane (KC-135) to measure the offset, which was determined to range between 0 and 50%. This range approximates the offset experienced in 1-g gas sensitivity testing.
Technical Paper

Status of ISS Oxygen Generation and Water Processor Assemblies

2003-07-07
2003-01-2691
Hamilton Sundstrand Space Systems International, Inc. (HSSSI) is under contract to NASA Marshall Space Flight Center (MSFC) to develop a Water Processor Assembly (WPA) and Oxygen Generation Assembly (OGA) for the international Space Station (ISS). The WPA produces potable quality water from humidity condensate, carbon dioxide reduction water, water obtained from fuel cells, reclaimed urine distillate, hand wash and oral hygiene waste waters. The Oxygen Generation Assembly (OGA) electrolyzes potable water from the Water Recovery System (WRS) to provide gaseous oxygen to the Space Station module atmosphere. The OGA produces oxygen for metabolic consumption by crew and biological specimens. The OGA also replenishes oxygen lost by experiment ingestion, airlock depressurization, CO2 venting, and leakage. As a byproduct, gaseous hydrogen is generated. The hydrogen will be supplied at a specified pressure range to support future utilization.
Technical Paper

Development, Testing, and Packaging of a Redundant Regenerable Carbon Dioxide Removal System (RRCRS)

2002-07-15
2002-01-2530
Enhancements to the Regenerable Carbon Dioxide Removal System (RCRS) have undergone full-scale, pre-prototype development and testing to demonstrate a redundant system within the volume allotted for the RCRS on the Space Shuttle Orbiter. The concept for a Redundant Regenerable Carbon Dioxide Removal System (RRCRS) utilizes the existing canister of the RCRS, but partitions it into two, independent, two-bed systems. This partitioning allows for two, fully capable RCRS units to be packaged within the original volume, thus reducing stowage volume and launch weight when compared to the flight RCRS plus the backup LiOH system. This paper presents the results of development and testing of a full-scale, pre-prototype RRCRS and includes an overview of the design concept for a redundant system that can be packaged within the existing envelope.
Technical Paper

Performance Testing of a New Membrane Evaporator for the Thermoelectric Integrated Membrane Evaporator System (TIMES) Water Processor

2002-07-15
2002-01-2525
The TIMES system was evaluated to determine its ability to process reverse osmosis (RO) brine as one of the Advanced Water Processor steps. Since preliminary testing performed in 1998 showed that the membrane typically used in the process (Nafion 117) offered a very poor ammonia rejection, a search for an alternate membrane exhibiting high ammonia rejection capability was initiated under NASA-JSC funding. This investigation has resulted in the selection of a PolyVinylAlcohol (PVA) composite membrane as a replacement. When processing RO brine and untreated human urine as feeds, the Pervap 2201 membrane showed a 96% ammonia rejection over a large range of ammonia concentration. The water permeation rates in both laboratory-scale and pilot scale testings were also similar to the Nafion. The water permeance of the Pervap 2201 was approximately 7.5 kg/h/m2/atm (1.1 lb/h/m2/psi).
Technical Paper

Sabatier CO2 Reduction System Design Status

2002-07-15
2002-01-2531
Carbon dioxide reduction in a closed loop life support system recovers water from otherwise waste carbon dioxide and hydrogen. Incorporation of a carbon dioxide reduction assembly (CRA) into the International Space Station life support system frees up thousands of pounds of payload capacity in the supporting Space Shuttle that would otherwise be required to transport water. Achievement of this water recovery goal requires coordination of the CRA design to work within the existing framework of the interface systems that are either already on orbit or well advanced in their development; namely, the Oxygen Generator Assembly (OGA), Carbon Dioxide Removal Assembly (CDRA) and Water Processor Assembly (WPA). The Oxygen Generation System (OGS) rack is in its final design phase and is scarred to accept later installation of the CRA.
Technical Paper

Catalyst Development for the Space Station Water Processor Assembly

2002-07-15
2002-01-2362
Hamilton Sundstrand Space Systems International (HSSSI) is currently under contract with NASA MSFC to design, fabricate and deliver the Water Processor Assembly (WPA) for the International Space Station (ISS). As part of this effort HSSSI has developed an oxidation catalyst for the catalytic reactor assembly in the WPA. This paper discusses full-scale development reactor testing and the status of the life testing of the oxidation catalyst used in the reactor.
Technical Paper

Development Status of ISS Water Processor Assembly

2002-07-15
2002-01-2363
Hamilton Sundstrand Space Systems International, Inc. (HSSSI) is under contract to NASA Marshall Space Flight Center (MSFC) to develop a Water Processor Assembly (WPA) for the International Space Station (ISS). The WPA produces potable quality water from humidity condensate, carbon dioxide reduction water, water obtained from fuel cells, reclaimed urine distillate, shower, handwash and oral hygiene wastewaters. All planned development testing has been completed and this paper provides the status of the development activities and results for the WPA.