Refine Your Search

Topic

Author

Affiliation

Search Results

Technical Paper

Direct Visualization of Soot and Ash Transport in Diesel Particulate Filters during Active Regeneration Process

2019-12-19
2019-01-2287
This study employed a diesel particulate generator (DPG), with an installed engine oil injector for soot and ash accumulation in a diesel particulate filter (DPF). Ash was generated by engine oil injection into the diesel burner flame. The amount of soot accumulation per loading varied from 0.5 g/L to 8 g/L while ash accumulation amount per loading was maintained at 0.5 g/L. Initially, ash accumulation distribution in the DPF was visualized using X-ray computed tomography (CT). It was revealed that the form of ash accumulation changed depending on the amount of soot accumulation before active regeneration, i.e., a large amount of soot accumulation resulted in plug ash, whereas a small amount of soot accumulation resulted in wall ash. To clarify ash accumulation mechanisms, soot and ash transport behavior in DPF during active regeneration process was directly observed using a high-speed camera through an optically accessible D-shaped cut DPF covered with a quartz glass plate.
Technical Paper

Prediction of Oil Dilution by Post-injection in DPF Regeneration Mode

2019-12-19
2019-01-2354
This work investigated the mechanism of oil dilution by post injection to remove accumulated particulate matter on the diesel particulate filter of diesel engines. We developed a model to simulate post injection spray under low ambient gas pressure conditions. The model can predict the quantity of fuel mass adhered on the cylinder wall. The adhered fuel enters oil sump through the piston ring and cause oil dilution. The fuel in diluted oil evaporates during normal engine operations. We focus on the mechanism of fuel evaporation from diluted oil. The effects of engine speed and oil temperature on the evaporation were investigated. The results showed that the fuel evaporation rate increases with increasing engine speed and oil temperature. Furthermore, we developed an empirical model to predict the fuel evaporation rate of diluted oil through regression analysis with measured data.
Technical Paper

Kinetic Measurements of HNCO Hydrolysis over SCR Catalyst

2018-09-10
2018-01-1764
To meet the strict emission regulations for diesel engines, an advanced processing device such as a Urea-SCR (selective catalytic reduction) system is used to reduce NOx emissions. The Real Driving Emissions (RDE) test, which is implemented in the European Union, will expand the range of conditions under which the engine has to operate [1], which will lead to the construction of a Urea-SCR system capable of reducing NOx emissions at lower and higher temperature conditions, and at higher space velocity conditions than existing systems. Simulations are useful in improving the performance of the urea-SCR system. However, it is necessary to construct a reliable NOx reduction model to use for system design, which covers the expanded engine operation conditions. In the urea-SCR system, the mechanism of ammonia (NH3) formation from injected aqueous urea solution is not clear. Thus, it is important to clarify this mechanism to improve the NOx reduction model.
Technical Paper

Simplifying the Structural Design of the Advanced Pedestrian Legform Impactor for Use in Standardized Testing

2018-04-03
2018-01-1049
The advanced Pedestrian Legform Impactor (aPLI) incorporates a number of enhancements for improved lower limb injury prediction capability with respect to its predecessor, the FlexPLI. The aPLI also incorporates a simplified upper body part (SUBP), connected to the lower limb via a mechanical hip joint, that expands the impactor’s applicability to evaluate pedestrian’s lower limb injury risk also in high-bumper cars.As the aPLI has been developed to be used in standardized testing, further considerations on the impactor’s manufacturability, robustness, durability, usability, and repeatability need to be accounted for.. The aim of this study is to define and verify, by means of numerical analysis, a battery of design modifications that may simplify the manufacturing and use of physical aPLIs, without reducing the impactors’ biofidelity. Eight candidate parameters were investigated in a two-step numerical analysis.
Journal Article

Prediction of Spray Behavior in Injected by Urea SCR Injector and the Reaction Products

2017-10-08
2017-01-2375
In the urea SCR system, urea solution is injected by injector installed in the front stage of the SCR catalyst, and NOx can be purified on the SCR catalyst by using NH3 generated by the chemical reaction of urea. NH3 is produced by thermolysis of urea and hydrolysis of isocyanic acid after evaporation of water in the urea solution. But, biuret and cyanuric acid which may cause deposit are sometimes generated by the chemical reactions without generating NH3. Spray behavior and chemical reaction of urea solution injected into the tail-pipe are complicated. The purpose of this study is to reveal the spray behavior and NH3 generation process in the tail-pipe, and to construct the model capable of predicting those accurately. In this report, the impingement spray behavior is clarified by scattered light method in high temperature flow field. Liquid film adhering to the wall and deposit generated after evaporation of water from the liquid film are photographed by the digital camera.
Technical Paper

Analysis of Spray Feature Injected by Tailpipe Injector for Aftertreatment of Diesel Engine Emissions

2017-10-08
2017-01-2373
Diesel Particulate Filter (DPF) is a very effective aftertreatment device to limit particulate emissions from diesel engines. As the amount of soot collected in the DPF increases, the pressure loss increases. Therefore, DPF regeneration needs to be performed. Injected fuel into the exhaust line upstream of the Diesel Oxidation Catalyst (DOC), hydrocarbons are oxidized on the DOC, which increases the exhaust gas temperature at the DPF inlet. It is also necessary that the injected fuel is completely vaporized before entering the DOC, and uniformly mixed with the exhaust gases in order to make the DOC work efficiency. However, ensuring complete evaporation and an optimum mixture distribution in the exhaust line are challenging. Therefore, it is important that the fuel spray feature is grasped to perform DPF regeneration effectively. The purpose of this study is the constructing a simulation model.
Technical Paper

Validation of Vibration Test for Lithium-ion Battery Pack in Electric Vehicles

2015-04-14
2015-01-1195
To verify the appropriateness of the vibration test conditions of ISO 12405, we performed tailoring to derive power spectrum densities and test durations as vibration test conditions. Vehicles used for tailoring included two electric vehicles and one plug-in hybrid electric vehicle. Those vehicles were equipped with accelerometers and were run on seven different road types at different speeds while data on the acceleration of the battery packs were recorded. The power spectrum densities for three axes that were derived from the obtained acceleration data were similar in form to the power spectrum densities of ISO 12405, and almost the same root mean square accelerations were obtained, confirming that they are appropriate. However, both experiments and theory suggest that the test duration for the Z-axis exceeds those of the X- and Y-axes.
Journal Article

Validation of the Localized Fire Test Method for On-Board Hydrogen Storage Systems

2014-04-01
2014-01-0421
The localized fire test provided in the Global Technical Regulation for Hydrogen Fuel Cell Vehicles gives two separate test methods: the ‘generic installation test - Method 1′ and the ‘specific vehicle installation test - Method 2′. Vehicle manufacturers are required to apply either of the two methods. Focused on Method 2, the present study was conducted to determine the characteristics and validity of Method 2. Test results under identical burner flame temperature conditions and the effects of cylinder protection covers made of different materials were compared between Method 1 and Method 2.
Journal Article

Comparison of Fires in Lithium-Ion Battery Vehicles and Gasoline Vehicles

2014-04-01
2014-01-0428
Electric vehicles have become more popular and may be involved in fires due to accidents. However, characteristics of fires in electric vehicles are not yet fully understood. The electrolytic solution of lithium-battery vehicles is inflammable, so combustion characteristics and gases generated may differ from those of gasoline cars. Therefore, we conducted fire tests on lithium-ion battery vehicles and gasoline vehicles and investigated the differences in combustion characteristics and gases generated. The fire tests revealed some differences in combustion characteristics. For example, in lithium-ion battery vehicles, the battery temperature remained high after combustion of the body. However, there was almost no difference in the maximum CO concentration measured 0.5 to 1 m above the roof and 1 m from the side of the body. Furthermore, HF was not detected in either type of vehicle when measured at the same positions as for CO.
Journal Article

Investigation of the Impact Phenomenon During Minor Collision

2013-04-08
2013-01-1545
ISO 12405-1,2 specifies international testing standards for lithium-ion batteries for vehicles. In the mechanical shock test is used to determine if the battery is damaged due to the shock imposed when the vehicle runs over a curb or similar minor accidents. Therefore, we conducted minor collision tests against a curb using an actual vehicle and compared the test results with the conditions specified in ISO 12405-1,2. The results confirmed that the impulse wave obtained using an actual vehicle within the range of the test in this study differs from the shape of the impulse wave specified in ISO 12405-1,2.
Technical Paper

Development of Electric Commuter Concept Car “C-ta”

2011-05-17
2011-39-7220
It is becoming more and more necessary to achieve a sustainable low-carbon society by mobility not depending on oil. Electric vehicles are appropriate for such a society, but expensive battery cost and long charging time prohibit the promotion of EVs. One of the solutions is minimizing battery usage by ultra-low fuel efficiency, so we developed an ultrahigh-efficient electric commuter concept car “C-ta”, which requires as small a battery as possible. We assumed that drivers would use the car as a second car for short-distance daily use, such as commuting, shopping, transportation of family, etc. In order to improve fuel efficiency, we mainly considered an ultra-light weight body and chassis, to which CFRP (carbon fiber reinforced plastic) greatly contributes, ultra-low rolling resistance tires, and highly accurate vehicle control technology with four in-wheel motors.
Technical Paper

Establishing Localized Fire Test Methods and Progressing Safety Standards for FCVs and Hydrogen Vehicles

2011-04-12
2011-01-0251
The SAE Fuel Cell Vehicle (FCV) Safety Working Group has been addressing FCV safety for over 11 years. In the past couple of years, significant attention has been directed toward a revision to the standard for vehicular hydrogen systems, SAE J2579(1). In addition to streamlining test methodologies for verification of Compressed Hydrogen Storage Systems (CHSSs) as discussed last year,(2) the working group has been considering the effect of vehicle fires, with the major focus on a small or localized fire that could damage the container in the CHSS and allow a burst before the Pressure Relief Device (PRD) can activate and safely vent the compressed hydrogen stored from the container.
Journal Article

Mixing-Controlled, Low Temperature Diesel Combustion with Pressure Modulated Multiple-Injection for HSDI Diesel Engine

2010-04-12
2010-01-0609
This paper proposes a new mixing-controlled, low temperature combustion (LTC) approach for high-speed direct injection (HSDI) diesel engines. The purpose of this approach is to avoid the excessively high pressure-rise rate (PRR) of premixed, kinetics-controlled LTC and to enable the low nitrogen oxides (NOx) combustion to operate over the wide speed and load range of the engine. To address the soot/noise trade-off at high load LTC operating conditions, the pressure modulated multiple-injection coupled with swirl control was applied. This injection strategy enables the injection of high pressure (HP) main spray into the local high temperature region of the already burning low pressure (LP) pilot spray injected from the neighboring injection hole. By employing this injection strategy, the equivalence ratio (φ) distribution of mixture is drastically varied during main combustion processes.
Journal Article

An Experimental Study on the Fire Response of Vehicles with Compressed Hydrogen Cylinders

2010-04-12
2010-01-0134
To investigate the events that could arise when fighting fires in vehicles with carbon fiber reinforced plastic (CFRP) hydrogen storage cylinders, we conducted experiments to examine whether a hydrogen jet diffusion flame caused by activation of the pressure relief device (PRD) can be extinguished and how spraying water influences the cylinder and PRD. The experiments clarified that the hydrogen jet flame cannot be extinguished easily with water or dry powder extinguishers and that spraying water during activation of the PRD may result in closure of the PRD, but is useful for maintaining the strength of CFRP composite cylinders for vehicles.
Technical Paper

Empirical Approach to Risk Factors in Rear End Collisions at Intersections - Effect of Lead Vehicle Behaviour on Premature Decisions of the Following Driver -

2010-04-12
2010-01-1014
Naturalistic driving data has been accumulated by driving data recorders to understand factors that contribute to collisions. Among the rear end conflicts at signalized intersections in the data, conflict data between the following vehicles and suddenly stopping lead vehicles were frequently observed just after their start. To investigate the following drivers' behavior in a realistic driving situation without collision danger, an instrumented vehicle equipped with a liquid-crystal display ahead of the windshield was developed, and an experiment reproducing such conflict on the display was conducted. It was found that a lead vehicle's rapid start (2.8 m/s₂ on average) before quitting its right turn caused the following vehicle's brake reaction time to be longer than a slow start (0.8 m/s₂ on average) did. This result suggests that a following driver's premature decision to start rapidly increases the risk of rear end collisions.
Technical Paper

Impact Study of High Biodiesel Blends on Exhaust Emissions to Advanced Aftertreatment Systems

2010-04-12
2010-01-1292
In Biodiesel Fuel Research Working Group(WG) of Japan Auto-Oil Program(JATOP), some impacts of high biodiesel blends have been investigated from the viewpoints of fuel properties, stability, emissions, exhaust aftertreatment systems, cold driveability, mixing in engine oils, durability/reliability and so on. In the impact on exhaust emissions, the impact of high biodiesel blends into diesel fuel on diesel emissions was evaluated. The wide variety of biodiesel blendstock, which included not only some kinds of fatty acid methyl esters(FAME) but also hydrofined biodiesel(HBD) and Fischer-Tropsch diesel fuel(FTD), were selected to evaluate. The main blend level evaluated was 5, 10 and 20% and the higher blend level over 20% was also evaluated in some tests. The main advanced technologies for exhaust aftertreatment systems were diesel particulate filter(DPF), Urea selective catalytic reduction (Urea-SCR) and the combination of DPF and NOx storage reduction catalyst(NSR).
Technical Paper

Developing Safety Standards for FCVs and Hydrogen Vehicles

2010-04-12
2010-01-0131
The SAE Fuel Cell Vehicle (FCV) Safety Working Group has been addressing FCV safety for over 10 years. The initial document, SAE J2578, was published in 2002. SAE J2578 has been valuable as a Recommended Practice for FCV development with regard to the identification of hazards associated with the integration of hydrogen and electrical systems onto the vehicle and the definition of countermeasures to mitigate these hazards such that FCVs can be operated in the same manner as conventional gasoline internal combustion engine (ICE)-powered vehicles. An update to SAE J1766 for post-crash electrical safety was also published in 2008 to reflect unique aspects of FCVs and to harmonize electrical requirements with international standards. In addition to SAE J2578 and J1766, the SAE FCV Safety Working Group also developed a Technical Information Report (TIR) for vehicular hydrogen systems (SAE J2579).
Journal Article

Developing Safety Standards for FCVs and Hydrogen Vehicles

2009-04-20
2009-01-0011
The SAE Fuel Cell Vehicle (FCV) Safety Working Group has been addressing FCV safety for over 9 years. The initial document, SAE J2578, was published in 2002. SAE J2578 has been valuable as a Recommended Practice for FCV development with regard to the identification of hazards and the definition of countermeasures to mitigate these hazards such that FCVs can be operated in the same manner as conventional gasoline internal combustion engine (ICE)-powered vehicles. SAE J2578 is currently being revised so that it will continue to be relevant as FCV development moves forward. For example, test methods were refined to verify the acceptability of hydrogen discharges when parking in residential garages and commercial structures and after crash tests prescribed by government regulation, and electrical requirements were updated to reflect the complexities of modern electrical circuits which interconnect both AC and DC circuits to improve efficiency and reduce cost.
Technical Paper

Impact Study of High Biodiesel Blends on Performance of Exhaust Aftertreatment Systems

2008-10-06
2008-01-2494
Biodiesel Fuel (BDF) Research Work Group works on identifying technological issues on the use of high biodiesel blends (over 5 mass%) in conventional diesel vehicles under the Japan Auto-Oil Program started in 2007. The Work Group conducts an analytical study on the issues to develop measures to be taken by fuel products and vehicle manufacturers, and to produce new technological findings that could contribute to the study of its introduction in Japan, including establishment of a national fuel quality standard covering high biodiesel blends. For evaluation of the impacts of high biodiesel blends on performance of diesel particulate filter system, a wide variety of biodiesel blendstocks were prepared, ranging from some kinds of fatty acid methyl esters (FAME) to another type of BDF such as hydrotreated biodiesel (HBD). Evaluation was mainly conducted on blend levels of 20% and 50%, but also conducted on 10% blends and neat FAME in some tests.
Technical Paper

Thermal Behavior in Hydrogen Storage Tank for FCV on Fast Filling (2nd Report)

2008-04-14
2008-01-0463
If a compressed hydrogen tank for vehicles is filled with hydrogen gas more quickly, the gas temperature in the tank will increase. In this study, we conducted hydrogen gas filling tests using the TYPE 3 and TYPE 4 tanks. During the tests, we measured the temperature of the internal liner surface and investigated its relationship with the gas temperature in the tank. We found that the gas temperature in the upper portion of the TYPE 4 tank rose locally during filling and that the temperature of the internal liner surface near that area also rose, resulting in a temperature higher than the gas temperature at the center of the tank. To keep the maximum temperature in the tank below the designed temperature (85°C) during filling and examine the representative tank internal temperatures, it is important to examine filling methods that can suppress local rises of tank internal temperature.
X