Refine Your Search

Search Results

Technical Paper

A Screening Attenuation Evaluation Method for HEV Power Cable

2008-04-14
2008-01-1476
This paper proposes a new screening attenuation evaluation method (PHSA) for hybrid power cables. Hybrid power cables connect battery, inverter and motor. As the noise and shield characteristics of these cables are different from general communication shield wires, new method for evaluating screening attenuation is needed. We considered the radiation direction, noise current path and various load terminations to evaluate the screening attenuation which is different from standard screening attenuation measurement. Feasibility and effectiveness of the proposed method were verified with real experiment results.
X