Refine Your Search

Topic

Search Results

Standard

Aircraft Oxygen Replenishment Coupling for Civil Transport Aircraft (Design Standard)

2021-03-09
WIP
AS1219B
This SAE Aerospace Design Standard defines a coupling, which is installed in a high pressure (1850 to 2000 psig) oxygen system of a civil transport aircraft for the purpose of mating to ground oxygen replenishment facilities. Dimensions developed from AND10089, Detail Specification Sheet for Fitting End, Design Standard, For Cone Connection.
Standard

Oxygen Sensor Technologies

2020-12-18
CURRENT
AIR5933
AIR5933 provides an overview of contemporary technologies (i.e., sensors) that measure the proportion of oxygen in a gas. The use of these sensors in the aerospace environment, with its special constraints, is discussed and papers/reports with detailed information are summarized and referenced. The sensors are divided into expendable and non-expendable sensors. Expendable sensors are based on electrochemical properties, whereas non-expendable sensors rely on paramagnetic, photo-acoustic, electromagnetic, and laser spectroscopy properties.
Standard

Personal Protective Devices for Toxic and Irritating Atmospheres Air Transport Flight Deck (Sedentary) Crewmembers

2020-09-03
WIP
AS8031B
This SAE Aerospace Standard (AS) covers any protection system that serves the stated purpose. This document establishes minimum performance requirements for emergency equipment, which provides flight deck (sedentary) crewmembers with eye and respiratory protection from toxic atmospheres during in-flight emergencies. Defintion of sedentary: "sedentary" is herein defined as those flight deck crewmembers that remain seated at their flight deck stations throughout the emergency. For those "nonsedentary" cabin crewmembers whose duty it is to leave their flight station during an emergency (for example, to actively locate and fight an on-board fire).
Standard

Aircraft Oxygen Replenishment Coupling for Civil Transport Aircraft (Design Standard)

2020-02-28
CURRENT
AS1219A
This SAE Aerospace Design Standard defines a coupling, which is installed in a high pressure (1850 to 2000 psig) oxygen system of a civil transport aircraft for the purpose of mating to ground oxygen replenishment facilities. Dimensions developed from AND10089, Detail Specification Sheet for Fitting End, Design Standard, For Cone Connection.
Standard

Oxygen Cylinder Installation Guide

2019-04-11
CURRENT
ARP5021B
This document provides guidance for oxygen cylinder installation on commerical aircraft based on airworthiness requirements, and methods practiced within aerospace industry. It covers considerations for oxygen systems from beginning of project phase up to production, maintenance, and servicing. The document is related to requirements of DOT-approved oxygen cylinders, as well to those designed and manufactured to standards of ISO 11119. However, its basic rules may also be applicable to new development pertaining to use of such equipment in an oxygen environment. For information regarding oxygen cylinders itself, also refer to AIR825/12.
Standard

Passenger Hypoxia Protection Utilizing Oxygen Enriched Gas Mixtures

2018-10-18
CURRENT
AIR6036
Currently, existing civil aviation standards address the design and certification of oxygen dispensing devices that utilize oxygen sources supplying at least 99.5% oxygen. This Aerospace Information Report discusses issues relating to the use in the passenger cabin of oxygen enriched breathing gas mixtures having an oxygen content of less than 99.5% and describes one method of showing that passenger oxygen dispensing devices provide suitable hypoxia protection when used with such mixtures.
Standard

Effects of Acute Altitude Exposure in Humans: Requirements for Physiological Protection

2017-11-07
HISTORICAL
AIR825/2
The intent of this SAE Aerospace Information Report (AIR) is to describe the effects of the environmental changes on human physiology and the protection required to avoid negative consequences resulting from altitude exposure. A brief presentation of basic terms and considerations required to discuss the topic of human physiology at altitude are followed by an overview of the cardiovascular and respiratory systems. Issues specifically related to human exposure to altitude are then discussed.
Standard

Oxygen Cylinder Quality, Serviceability, Maintenance Transfilling and Marking

2017-05-19
HISTORICAL
AIR1059E
This document provides guidance concerning the maintenance and serviceability of oxygen cylinders beginning with the quality of oxygen that is required, supplemental oxygen information, handling and cleaning procedures, transfilling and marking of serviced oxygen assemblies. This document attempts to outline in a logical sequence oxygen quality, serviceability, and maintenance of oxygen cylinders. Content of this document can also be used for refilling of oxygen cylinder while installed on aircraft, directly or through an intermediate charging port.
Standard

Oxygen Cylinder Installation Guide

2016-11-18
HISTORICAL
ARP5021A
This document provides guidance for oxygen cylinder installation on commercial aircraft based on rules and methods practiced in aerospace industry and applicable in other associations. It covers considerations for oxygen systems from beginning of project phase up to production, maintenance, and servicing. The document is focused on requirements regarding DOT approved oxygen cylinders. However, its basic rules may also be applicable to new development pertaining to use of such equipment in an oxygen environment. For information regarding oxygen cylinders itself, reference should be made to AIR825/12 also.
Standard

Determination of Chlorine in Oxygen from Solid Chemical Oxygen Generators

2012-10-15
CURRENT
ARP1320B
This ARP covers a procedure to be used in the determination of 0.05 to 0.3 ppm of chlorine in oxygen from any type of generator used for emergency or other life-support systems. The methyl orange method described can be considered as a referee technique. Instrumental analysis is also given in Section 8.
Standard

Determination of Chlorine in Oxygen from Solid Chemical Oxygen Generators

2011-06-21
HISTORICAL
ARP1320A
This ARP covers a procedure to be used in the determination of 0.05 to 0.3 ppm of chlorine in oxygen from any type of generator used for emergency or other life-support systems. The methyl orange method described can be considered as a referee technique. Instrumental analysis is also given in Section 8.
Standard

Oxygen Cylinder Quality, Serviceability, Maintenance Transfilling and Marking

2010-10-14
HISTORICAL
AIR1059C
This document provides guidance concerning the maintenance and serviceability of oxygen cylinders beginning with the quality of oxygen that is required, supplemental oxygen information, handling and cleaning procedures, transfilling and marking of serviced oxygen assemblies. This document attempts to outline in a logical sequence oxygen quality, serviceability and maintenance of oxygen cylinders.
Standard

Aerospace Information Report for Continuous Flow Oxygen Hose Disconnect Fittings

2009-08-27
HISTORICAL
AIR1358B
This Aerospace Information Report (AIR) indicates those dimensions, deemed critical by the manufacturer to assure proper mating of disconnect hose fittings. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
Standard

Transfilling and Maintenance of Oxygen Cylinders

2008-11-17
HISTORICAL
AIR1059B
The purpose of this document is to list the best available information and guidelines for the qualification of personnel who are responsible for the filling of fixed or portable aircraft oxygen cylinders.
Standard

Oxygen Cylinder Installation Guide

2005-10-24
HISTORICAL
ARP5021
This document provides guidance for oxygen cylinder installation on commercial aircraft based on rules and methods practiced in aerospace industry and as far as applicable in other associations. It covers considerations to be taken for oxygen systems from beginning of project phase up to production, maintenance, and servicing. The document is focused on requirements regarding DOT approved oxygen cylinders. However, its basic rules may also be applicable to new development pertaining to use of such equipment in an oxygen environment. For information regarding oxygen cylinders itself, reference should be made to AIR825/12 also.
Standard

Closed-Cycle Protective Breathing Devices

2001-12-14
HISTORICAL
AIR825/11
Closed-cycle protective breathing apparatus, commonly referred to as rebreathers, or CCBA provide trained aircrew members or ground personnel with eye and respiratory protection from toxic atmospheres.
Standard

AEROSPACE INFORMATION REPORT FOR CONTINUOUS FLOW OXYGEN HOSE DISCONNECT FITTINGS

1991-09-01
HISTORICAL
AIR1358
This AIR indicates those dimensions, deemed critical by the manufacturer, which are required to be adhered to so that proper mating of the disconnect hose fitting with the correct disconnect be accomplished. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
X