Refine Your Search

Topic

Search Results

Standard

Insulation Sleeving, Electrical, Heat Shrinkable, General Specification for

2022-10-13
HISTORICAL
AS23053B
This specification establishes the requirements for various types and colors of electrical insulating sleeving that will shrink to a predetermined size upon the application of heat. This specification includes provisions for demonstrating compliance with qualification requirements (see Section 4 and 7.3), in process inspection, and statistical process control inspections (see 4.4). The continuous operating temperature ranges for the sleeving classes covered by this specification are from -112 to +482 °F (-80 to +250 °C). The continuous operating temperature range for each sleeving class is given in the applicable detail specification.
Standard

Laser Wire Stripping Tools, General Understanding

2022-08-26
CURRENT
AIR6894A
This SAE Aerospace Information Report (AIR) describes laser wire stripping technologies and recommendations to strip electrical single conductor wires and shielded cables intended for aerospace applications. These recommendations include: Laser types for wire stripping Laser stripping system configuration Quality assurance Tool qualification Tool inspection User health and safety
Standard

Fluoride Offgassing in Fluoropolymer Insulations

2020-03-24
CURRENT
ARP6229
This SAE Aerospace Recommended Practice (ARP) shall be limited to information about corrosion caused by fluoride offgassing of fluoropolymer-based wire insulation. It reviews published reports of corrosion caused by this phenomenon, describes scenarios where this may be a concern, mitigation options, and references a test method which can be used to evaluate wire insulations where needed.
Standard

Insulation Sleeving, Electrical, Heat Shrinkable, General Specification for

2019-04-08
HISTORICAL
AS23053A
This specification establishes the requirements for various types and colors of electrical insulating sleeving that will shrink to a predetermined size upon the application of heat. This specification includes provisions for demonstrating compliance with qualification requirements (see Section 4 and 7.3), in process inspection, and statistical process control inspections (see 4.4). The continuous operating temperature ranges for the sleeving classes covered by this specification are from -112 to +482 °F (-80 to +250 °C). The continuous operating temperature range for each sleeving class is given in the applicable detail specification.
X