Refine Your Search

Topic

Search Results

Standard

PERFORMANCE SPECIFICATION FOR AUTOMOTIVE RF CONNECTOR SYSTEMS

2023-07-10
CURRENT
USCAR17-6
This document contains procedures for testing performance of SMB-style electrical terminals, connectors and components for coaxial cable connection systems intended for road vehicle applications. These are often called FAKRA II designs. This specification does not apply to the Non RF portion of a Hybrid RF connection system. The intent of this specification is to qualify sealed and unsealed RF connectors that operate at frequencies from DC to 6 GHz. The characteristic impedance of the SMB/FAKRA connection system is 50 ohms however this specification does not exclude the use of these RF connectors on non-50 ohm cables or systems. This specification does not apply to single conductor wire or twisted pair connection systems. This specification (along with SAE/USCAR 18) is designed to provide the mechanical and electrical data required to insure that assemblies from various manufacturers will perform reliably in actual conditions.
Standard

PERFORMANCE SPECIFICATION FOR AUTOMOTIVE UNIVERSAL SERIAL BUS (USB) CONNECTION SYSTEM

2022-07-04
HISTORICAL
USCAR30
Procedures included within this specification are intended to cover performance testing at all phases of development, production, and field analysis of any USB cable assemblies and associated connections that constitute the electrical connection systems between the consumer peripheral interface and the USB computer source in road vehicle applications. These procedures are only applicable to the USB connector and the cable. Unless otherwise specified, all of the tests listed in this specification are for both consumer and nonconsumer interface connectors.
Standard

TEST PROCEDURE FOR ELECTRICAL GROUND ATTACHMENTS

2022-02-25
HISTORICAL
USCAR26
This test procedure is intended to evaluate and/or validate electrical ground schemes for use on the body or chassis. There are two classes based on the expected environmental conditions. Exposed Grounds can be located anywhere in the vehicle (except on the powertrain) and is the class for which most schemes should be tested. Unexposed Grounds can only be used in the passenger compartment or trunk and as such are special cases. This procedure as written is not intended for testing powertrain grounds where high temperatures and vibration levels may be encountered. These situations may require modifications to this procedure and are left to the Responsible Engineer to determine. This specification does not specifically address validation of terminal to wire electrical crimps. Crimps are tested to SAE/USCAR-21
Standard

STANDARD FOR TIRE TRACEABILITY CONTENT AND FORMAT FOR THE RADIO-FREQUENCY IDENTIFICATION (RFID) TAG AND ASSOCIATED TIRE DATA SET

2020-11-19
CURRENT
USCAR39-1
This standard describes a requirement for automotive tire traceability. It includes a definition of the RFID tag and the associated tire data set that can be accessed using the RFID tag as an identifier. The standard describes a unique identification and the associated data set for each tire produced by the tire fabricator. This data will either be provided or transmitted at the time of shipment to retailers, wholesalers or original equipment vehicle manufacturers. Tire identification code and data may be used for error proofing, determining the tire specifications or supporting any inquiries that occur for the duration of its automotive life.
Standard

LEAD-FREE SOLDER VALIDATION TEST PLAN

2020-11-19
CURRENT
USCAR40-2
This guideline is applicable to existing lead solder production products that will change to lead-free solder processes to meet the ELV Directive 2000/53/EC Annex II, exemption 8B requirements. This guideline is applicable to similar products used by multiple OEM's that have the same manufacturing processes / equipment. The intent is to streamline the supplier’s environmental testing via common qualification to reduce timing, quantities, and costs.
Standard

DEEMBRITTLEMENT VERIFICATION TEST

2020-11-19
CURRENT
USCAR7-2
This standard outlines test methods and practices which can detect embrittlement of steel parts. It is a process control or referee verification test. The risk of embrittlement of steel is minimized by using best practices in the finishing/coating process. One such practice is described in SAE/USCAR-5, Avoidance of Hydrogen Embrittlement of Steel.
Standard

STANDARD FOR TIRE TRACEABILITY CONTENT AND FORMAT FOR THE RADIO-FREQUENCY IDENTIFICATION (RFID) TAG AND ASSOCIATED TIRE DATA SET

2019-04-17
HISTORICAL
USCAR39
This standard describes a requirement for automotive tire traceability. It includes a definition of the RFID tag and the associated tire data set that can be accessed using the RFID tag as an identifier. The standard describes a unique identification and the associated data set for each tire produced by the tire fabricator. This data will either be provided or transmitted at the time of shipment to retailers, wholesalers or original equipment vehicle manufacturers. Tire identification code and data may be used for error proofing, determining the tire specifications or supporting any inquiries that occur for the duration of its automotive life.
Standard

Lead-Free Solder Validation Test Plan

2015-04-22
HISTORICAL
USCAR40-1
This guideline is applicable to existing lead solder production products that will change to lead-free solder processes to meet the ELV Directive 2000/53/EC Annex II, exemption 8B requirements. This guideline is applicable to similar products used by multiple OEM's that have the same manufacturing processes / equipment. The intent is to streamline the supplier’s environmental testing via common qualification to reduce timing, quantities, and costs.
Standard

Ergonomic Guidelines for Small Lot Delivery Operations

2015-03-10
CURRENT
USCAR42
This document describes the design, assessment methods and physical requirements associated with material handling systems. This would include, but not limited to manual dollies, small lot systems and kitting. All possible designs and applications could not be anticipated in creating these guidelines. Where there are questions of adherence to this document, such as use of an “off-the shelf” design, always consult the responsible Ergonomics Department.
Standard

PERFORMANCE SPECIFICATION FOR CABLE-TO-TERMINAL ELECTRICAL CRIMPS

2014-11-01
HISTORICAL
USCAR21-3
This specification defines test methods and requirements for validation of solderless crimped connections. The purpose of this test is to simulate in the lab the stress seen in a typical life (15 years and 150,000 miles) for a crimp connection and assure the crimp is mechanically strong and electrically stable. This specification was developed for use with stranded automotive copper wire. Only where specifically mentioned are other constructions or other core materials (aluminum, clad, steel core, etc.) applicable. This specification does not apply to wire types not mentioned. This specification is based on accepted levels of environmental exposure for automotive applications.
Standard

Standard for Cigar Lighters & Power Outlets

2014-03-31
CURRENT
USCAR4-1
This standard is intended to cover cigar or cigarette lighters as well as power outlets based on the form and dimensions of the cigar lighter. This standard is a full performance specification, it includes dimensional and operational parameters as well as performance characteristics which must be met when submitting a cigar lighter assembly or power outlet assembly for production approval. This standard constitutes an acceptance specification for a surface mounted, front-loaded cigar lighter or power outlet.
Standard

DEEMBRITTLEMENT VERIFICATION TEST

2012-07-30
HISTORICAL
USCAR7-1
This standard outlines test methods and practices which can detect embrittlement of steel parts. It is a process control or referee verification test. The risk of embrittlement of steel is minimized by using best practices in the finishing/coating process. One such practice is described in SAE/USCAR-5, Avoidance of Hydrogen Embrittlement of Steel.
Standard

LEAD-FREE SOLDER VALIDATION TEST PLAN

2011-04-01
HISTORICAL
USCAR40
This guideline is applicable to existing lead solder production products that will change to lead-free solder processes to meet the ELV Directive 2000/53/EC Annex II, exemption 8B requirements. This guideline is applicable to similar products used by multiple OEM's that have the same manufacturing processes / equipment. The intent is to streamline the supplier’s environmental testing via common qualification to reduce timing, quantities, and costs.
Standard

Performance Specification for Ultrasonically Welded Wire/Cable Termination

2009-12-18
HISTORICAL
USCAR38
IMPORTANT NOTICE: In any intended vehicle application, if the products covered by this specification are, or may be, subjected to conditions beyond those described in this document, they must pass special tests simulating the actual conditions to be encountered before they can be considered acceptable for actual vehicle application. Products certified by their supplier as having passed specific applicable portions of this specification are not to be used in applications where conditions may exceed those for which the product has been satisfactorily tested. The Authorized Person is the final authority as to what tests are to be performed on his or her parts and for what purpose these tests are required. He or she is also the final authority for resolving any questions related to testing to this specification and to authorizing any deviations to the equipment or procedures contained in this specification.
Standard

HIGH VOLTAGE CONNECTOR PERFORMANCE SUPPLEMENT TO SAE/USCAR-2

2008-08-27
CURRENT
USCAR37
Procedures included within this specification supplement are, when used in conjunction with SAE/USCAR 2, intended to cover performance testing at all phases of development, production, and field analysis of electrical terminals, connectors, and components that constitute the electrical connection systems in high voltage (60~600V) road vehicle applications. These procedures are applicable to terminals used for In-Line, Header, and Device Connector systems with and without Shorting Bars. This supplement applies to both sealed and unsealed connection systems.
Standard

Initiator Technical Requirements and Validation

2005-06-06
CURRENT
USCAR28
This specification establishes the design, performance, and validation requirements for the initiator assembly used in airbag modules, seatbelt pretensioners and/or any other Electro-Explosive Devices (EED).
Standard

FIELD CORRELATED LIFE TEST SUPPLEMENT TO SAE/USCAR-2

2004-06-23
HISTORICAL
USCAR20-1
This life test for underhood/passenger/trunk connector systems may be used in place of Section 5.9.6, Connection System Electrical Table of SAE/USCAR-2. All other requirements of SAE/USCAR-2 remain applicable even when this test is used. Refer to SAE/USCAR-2 and Connector/Terminal Supplier for appropriate power rating and current cycle Testing.
Standard

ELECTRICAL CONNECTOR ASSEMBLY ERGONOMIC DESIGN CRITERIA

2003-05-03
HISTORICAL
USCAR25
This document describes the design and assembly force guidelines for conventional and mechanical assist (lever and slide-lock) electrical connectors and CPA’s. All possible designs and applications cannot be anticipated in creating these guidelines. Where there are questions of adherence to this document, such as use of an “off-the-shelf” design, always consult the responsible Ergonomics department. Refer to SAE/USCAR-12 Wiring Component Design Guidelines for additional guidelines.
Standard

PERFORMANCE STANDARD FOR AUTOMOTIVE ELECTRICAL CONNECTOR SYSTEMS

2001-04-01
HISTORICAL
USCAR2
Procedures included within this specification are intended to cover performance testing at all phases of development, production, and field analysis of electrical terminals, connectors, and components that constitute the electrical connection systems in low voltage (0 - 20 VDC) road vehicle applications. These procedures are only applicable to terminals used for In-Line, Header, and Device connector systems. They are not applicable to Edge Board connector systems, > 20 VAC or DC, or to eyelet type terminals. Note that this specification does not cover the mechanical assist portions of connectors that include such devices. The Authorized Person must provide details of any additional testing desired to validate these mechanisms as part of the test request/order.
X