Refine Your Search

Topic

Search Results

Journal Article

Failure Analysis of Cryogenically Treated and Gas Nitrided Die Steel in Rotating Bending Fatigue

2024-04-24
Abstract AISI H13 hot work tool steel is commonly used for applications such as hot forging and hot extrusion in mechanical working operations that face thermal and mechanical stress fluctuations, leading to premature failures. Cryogenic treatment was applied for AISI H13 steel to improve the surface hardness and thereby fatigue resistance. This work involves failure analysis of H13 steel specimens subjected to cryogenic treatment and gas nitriding. The specimens were heated to 1020°C, oil quenched followed by double tempering at 550°C for 2 h, and subsequently, deep cryogenically treated at −185°C in the cryochamber. Gas nitriding was carried out for 24 h at 500°C for 200 μm case depth in NH3 surroundings. The specimens were subjected to rotating bending fatigue at constant amplitude loading at room temperature.
Journal Article

Bayesian Network Model and Causal Analysis of Ship Collisions in Zhejiang Coastal Waters

2024-04-10
Abstract For taking counter measures in advance to prevent accidental risks, it is of significance to explore the causes and evolutionary mechanism of ship collisions. This article collects 70 ship collision accidents in Zhejiang coastal waters, where 60 cases are used for modeling while 10 cases are used for verification (testing). By analyzing influencing factors (IFs) and causal chains of accidents, a Bayesian network (BN) model with 19 causal nodes and 1 consequential node is constructed. Parameters of the BN model, namely the conditional probability tables (CPTs), are determined by mathematical statistics methods and Bayesian formulas. Regarding each testing case, the BN model’s prediction on probability of occurrence is above 80% (approaching 100% indicates the certainty of occurrence), which verifies the availability of the model. Causal analysis based on the backward reasoning process shows that H (Human error) is the main IF resulting in ship collisions.
Journal Article

Assessing the Impact of Rubberized Asphalt on Reducing Hip Fracture Risk in Elderly Populations Using Human Body Models

2024-04-08
Abstract Compared to other age groups, older adults are at more significant risk of hip fracture when they fall. In addition to the higher risk of falls for the elderly, fear of falls can reduce this population’s outdoor activity. Various preventive solutions have been proposed to reduce the risk of hip fractures ranging from wearable hip protectors to indoor flooring systems. A previously developed rubberized asphalt mixture demonstrated the potential to reduce the risk of head injury. In the current study, the capability of the rubberized asphalt sample was evaluated for the risk of hip fracture for an average elderly male and an average elderly female. A previously developed human body model was positioned in a fall configuration that would give the highest impact forces toward regular asphalt.
Journal Article

Microstructural and Corrosion Behavior of Thin Sheet of Stainless Steel-Grade Super Duplex 2507 by Gas Tungsten Arc Welding

2024-03-21
Abstract Super duplex stainless steel (SDSS) is a type of stainless steel made of chromium (Cr), nickel (Ni), and iron (Fe). In the present work, a 1.6 mm wide thin sheet of SDSS is joined using gas tungsten arc welding (GTAW). The ideal parameter for a bead-on-plate trial is found, and 0.216 kJ/mm of heat input is used for welding. As an outcome of the welding heating cycle and subsequent cooling, a microstructural study revealed coarse microstructure in the heat-affected zone and weld zone. The corrosion rate for welded joints is 9.3% higher than the base metal rate. Following the corrosion test, scanning electron microscope (SEM) analysis revealed that the welded joint’s oxide development generated a larger corrosive attack on the weld surface than the base metal surface. The percentages of chromium (12.5%) and molybdenum (24%) in the welded joints are less than those in the base metal of SDSS, as per energy dispersive X-ray (EDX) analysis.
Journal Article

TOC

2024-02-12
Abstract TOC
Journal Article

TOC

2023-12-18
Abstract TOC
Journal Article

Influence of High-Strength, Low-Alloy Steel on Fatigue Life at a Non-Load-Bearing Transverse Welded Attachment

2023-11-17
Abstract This study investigated the influence of high-strength low-alloy steel on the fatigue life of a load-bearing member with a non-load-bearing transverse welded attachment (T-joint). It compared high cycle fatigue data to two fatigue design codes, namely BS 7608 and Eurocode EN 1993-1-9. Different base and filler material combinations of varying material strengths were investigated, resulting in a total of three different specimen configurations. Two material combinations had a high-strength steel (Strenx® 700 MC D) for the base material, with one combination having a matched filler material and the other having an undermatched filler material. The third material combination had a lower-strength steel (S 355 JR AR) for the base material, with a matched filler material. Tensile tests were performed to confirm the base material mechanical properties and weld quality of the manufactured specimens.
Journal Article

Study of Vehicle-Based Metrics for Assessing the Severity of Side Impacts

2023-10-30
Abstract A research program has been launched in Iran to develop an evaluation method for comparing the safety performance of vehicles in real-world collisions with crash test results. The goal of this research program is to flag vehicle models whose safety performance in real-world accidents does not match their crash test results. As part of this research program, a metric is needed to evaluate the severity of side impacts in crash tests and real-world accidents. In this work, several vehicle-based metrics were analyzed and calculated for a dataset of more than 500 side impact tests from the NHTSA crash test database. The correlation between the metric values and the dummy injury criteria was studied to find the most appropriate metric with the strongest correlation coefficient values with the dummy injury criteria.
Journal Article

Effect of Heat Treatment on Microstructure and Mechanical Properties of Medium-Carbon Steel Drawn Wire

2023-09-29
Abstract In this article, the effect of heat treatment on the microstructure and mechanical behavior of medium-carbon steel wire intended for the spring mattress is investigated using scanning electron microscopy (SEM), electron backscatter diffraction (EBSD), X-ray diffraction, Vickers hardness (Hv), and tensile strength. The results indicate that the microstructure elongation along the wire axis is observed with the bending and kinking lamellae at the deformation level of 57.81%, this change appears as a fracture in the microstructure and leads to an increase in hardness, tensile strength, and intensities of diffraction patterns. After heat treatment, we observed a redistribution in the grain, which is almost the same in the wire rod and drawn wires; indeed, this led to a decrease in hardness, tensile strength, and augmentation in intensities of peaks. The EBSD pole figures reveal the development of texture in the cementite slip plane (001).
Journal Article

100 Years of Corrosion Testing—Is It Time to Move beyond the ASTM D130? The Wire Corrosion and Conductive Deposit Tests

2023-09-22
Abstract The ASTM D130 was first issued in 1922 as a tentative standard for the detection of corrosive sulfur in gasoline. A clean copper strip was immersed in a sample of gasoline for three hours at 50°C with any corrosion or discoloration taken to indicate the presence of corrosive sulfur. Since that time, the method has undergone many revisions and has been applied to many petroleum products. Today, the ASTM D130 standard is the leading method used to determine the corrosiveness of various fuels, lubricants, and other hydrocarbon-based solutions to copper. The end-of-test strips are ranked using the ASTM Copper Strip Corrosion Standard Adjunct, a colored reproduction of copper strips characteristic of various degrees of sulfur-induced tarnish and corrosion, first introduced in 1954. This pragmatic approach to assessing potential corrosion concerns with copper hardware has served various industries well for a century.
Journal Article

Effect of Torso Boundary Conditions on Spine Kinematic and Injury Responses in Head-First Impact Assessed with a 50th Percentile Male Human Body Model

2023-09-20
Abstract Computational and experimental studies have been undertaken to investigate injurious head-first impacts (HFI), which can occur during automotive rollovers. Recent studies assume a torso surrogate mass (TSM) boundary condition, wherein the first or first two thoracic vertebrae are potted and constrained to only move in the vertical loading direction. The TSM boundary condition has not been compared with a full body (FB) model computationally or experimentally for HFI. In this study, the Global Human Body Models Consortium 50th percentile male detailed human body model (M50-O, Version 6.0) was applied to compare the kinematic, kinetic, and injury response of an HFI with a TSM boundary condition (M50-TSM), and a full body boundary condition (M50-FB). Impacts (to M50-TSM and M50-FB) were simulated between the head and a rigid plate using a commercial FE code (LS-DYNA).
Journal Article

Improved Predictions of Human Rib Structural Properties Using Bone Mineral Content

2023-09-20
Abstract Rib fractures are associated with high rates of morbidity and mortality. Improved methods to assess rib bone quality are needed to identify at-risk populations. Quantitative computed tomography (QCT) can be used to calculate volumetric bone mineral density (vBMD) and bone mineral content (BMC), which may be related to rib fracture risk. The objective of this study was to determine if vBMD and BMC from QCT predict human rib structural properties. 127 mid-level (5th–7th) ribs were obtained from adult female (n = 67) and male (n = 60) postmortem human subjects (PMHS). Isolated rib QCT scans were performed to calculate vBMD and BMC.
Journal Article

Developing an Ovine Model of Impact Traumatic Brain Injury

2023-09-20
Abstract Traumatic brain injury is a leading cause of global death and disability. Clinically relevant large animal models are a vital tool for understanding the biomechanics of injury, providing validation data for computation models, and advancing clinical translation of laboratory findings. It is well-established that large angular accelerations of the head can cause TBI, but the effect of head impact on the extent and severity of brain pathology remains unclear. Clinically, most TBIs occur with direct head impact, as opposed to inertial injuries where the head is accelerated without direct impact. There are currently no active large animal models of impact TBI. Sheep may provide a valuable model for studying TBI biomechanics, with relatively large brains that are similar in structure to that of humans. The aim of this project is to develop an ovine model of impact TBI to study the relationships between impact mechanics and brain pathology.
Journal Article

Restraint System Optimizations Using Diverse Human Body Models in Frontal Crashes

2023-09-20
Abstract Objective: This study aimed to optimize restraint systems and improve safety equity by using parametric human body models (HBMs) and vehicle models accounting for variations in occupant size and shape as well as vehicle type. Methodology: A diverse set of finite element (FE) HBMs were developed by morphing the GHBMC midsize male simplified model into statistically predicted skeleton and body shape geometries with varied age, stature, and body mass index (BMI). A parametric vehicle model was equipped with driver, front passenger, knee, and curtain airbags along with seat belts with pretensioner(s) and load limiter and has been validated against US-NCAP results from four vehicles (Corolla, Accord, RAV4, F150). Ten student groups were formed for this study, and each group picked a vehicle model, occupant side (driver vs. passenger), and an occupant model among the 60 HBMs.
Journal Article

Summary of Poster Abstracts

2023-09-20
Eighteen research posters were prepared and presented by student authors at the 18th Annual Injury Biomechanics Symposium. The posters covered a wide breadth of works-in-progress and recently completed projects.
Journal Article

Impact Area and Speed Effects on Powered Two-Wheeler Crash Fatality and Injury Risk

2023-09-20
Abstract The primary objective of this study was to evaluate the fatality risk of powered two-wheeler (PTW) riders across different impact orientations while controlling for different opponent vehicle (OV) types. For the crash configurations with higher fatality rate, the secondary objective was to create an initial speed–fatality prediction model specific to the United States. Data from the NHTSA Crash Reporting Sampling System and the Fatality Analysis Reporting System from 2017 to 2020 was used to estimate the odds of the different possible vehicle combinations and orientations in PTW–OV crashes. Binary logistic regression was then used to model the speed–fatality risk relationship for the configurations with the highest fatality odds. Results showed that collisions with heavy trucks were more likely to be fatal for PTW riders than those with other OV types.
Journal Article

A Parametric Thoracic Spine Model Accounting for Geometric Variations by Age, Sex, Stature, and Body Mass Index

2023-09-20
Abstract In this study, a parametric thoracic spine (T-spine) model was developed to account for morphological variations among the adult population. A total of 84 CT scans were collected, and the subjects were evenly distributed among age groups and both sexes. CT segmentation, landmarking, and mesh morphing were performed to map a template mesh onto the T-spine vertebrae for each sampled subject. Generalized procrustes analysis (GPA), principal component analysis (PCA), and linear regression analysis were then performed to investigate the morphological variations and develop prediction models. A total of 13 statistical models, including 12 T-spine vertebrae and a spinal curvature model, were combined to predict a full T-spine 3D geometry with any combination of age, sex, stature, and body mass index (BMI). A leave-one-out root mean square error (RMSE) analysis was conducted for each node of the mesh predicted by the statistical model for every T-spine vertebra.
Journal Article

Evaluation of Skin Penetration from Less Lethal Impact Munitions and Their Associated Risk Predictors

2023-09-20
Abstract Introduction: The use of less lethal impact munitions (LLIMs) by law enforcement has increased in frequency, especially following nationwide protests regarding police brutality and racial injustice in the summer of 2020. There are several reports of the projectiles causing severe injuries when they penetrate the skin including pulmonary contusions, bone fractures, liver lacerations, and, in some cases, death. The penetration threshold of skin in different body regions is due to differences in the underlying structure (varying degree of muscle, adipose tissue, and presence or absence of bone). Objective: The objective of this study was to further investigate what factors affected the likelihood of skin penetration in various body regions and to develop corresponding penetration risk curves.
Journal Article

Smoothed Particle Hydrodynamics to Model Spinal Canal Occlusion of a Finite Element Functional Spinal Unit Model under Compression

2023-09-20
Abstract Compressive impacts on the cervical spine can result in bony fractures. Bone fragments displaced into the spinal canal produce spinal canal occlusion, increasing the potential for spinal cord injury (SCI). Human body models (HBMs) provide an opportunity to investigate SCI but currently need to be improved in their ability to model compression fractures and the resulting material flow. Previous work to improve fracture prediction included the development of an anisotropic material model for the bone (hard tissues) of the vertebrae assessed in a functional spinal unit (FSU) model. In the FSU model, bony failure was modeled with strain-based element erosion, with a limitation that material that could occlude the spinal canal during compression was removed when an element was eroded.
X