Refine Your Search

Topic

Search Results

Technical Paper

Using Artificial Ash to Improve GPF Performance at Zero Mileage

2019-04-02
2019-01-0974
Gasoline particulate filters (GPF) with high filtration efficiency (>80%) at zero mileage are in growing demand to meet increasingly tight vehicle emission standards for particulate matter being implemented in US, EU, China and elsewhere. Current efforts to achieve high filter performance mainly focus on fine-tuning the filter structure, such as the pore size distribution and porosity of the bare substrate, or the washcoat loading and location of catalyzed substrates. However, high filtration efficiency may have a cost in high backpressure that negatively affects engine power. On the other hand, it has been recognized in a few reports that very low amounts of ash deposits (from non-combustible residue in the exhaust) can significantly increase filtration efficiency with only a mild backpressure increase.
Technical Paper

Gasoline Particulate Filter Efficiency and Backpressure at Very Low Mileage

2018-04-03
2018-01-1259
The need for gasoline particulate filter (GPF) technology is expected to grow with increasingly tight particle emissions standards being implemented in US, EU, China and elsewhere. Derived from the successful experience with diesel particulate filters (DPF), GPFs adopted the characteristic alternately plugged honeycomb structure that provides a large area of porous cordierite wall for filtering particles with minimal additional backpressure. However, unlike DPFs, continuous soot regeneration in GPFs makes it difficult to grow and sustain the soot cake on the filter wall that gives DPFs their high filtration efficiency. Therefore, filtration performance of low mileage GPFs relies heavily on the porous structure of filter media, which depends on both the substrate and the applied washcoat. In this work, a blank, two fresh washcoated filters and two washcoated filters with 3000 km mileage accumulation were characterized to compare their filtration performance.
Technical Paper

The Development of Low Temperature Three-Way Catalysts for High Efficiency Gasoline Engines of the Future: Part II

2018-04-03
2018-01-0939
It is anticipated that future gasoline engines will have improved mechanical efficiency and consequently lower exhaust temperatures at low load conditions, although the exhaust temperatures at high load conditions are expected to remain the same or even increase due to the increasing use of downsized turbocharged engines. In 2014, a collaborative project was initiated at Ford Motor Company, Oak Ridge National Lab, and the University of Michigan to develop three-way catalysts with improved performance at low temperatures while maintaining the durability of current TWCs. This project is funded by the U.S. Department of Energy and is intended to show progress toward the USDRIVE target of 90% conversion of hydrocarbons (HC), carbon monoxide (CO), and nitrogen oxides (NOx) at 150 °C after high mileage aging. The testing protocols specified by the USDRIVE ACEC team for stoichiometric S-GDI engines were utilized during the evaluation of experimental catalysts at all three facilities.
Technical Paper

A Modeling Analysis of Fibrous Media for Gasoline Particulate Filters

2017-03-28
2017-01-0967
With an emerging need for gasoline particulate filters (GPFs) to lower particle emissions from gasoline direct injection (GDI) engines, studies are being conducted to optimize GPF designs in order to balance filtration efficiency, backpressure penalty, filter size, cost and other factors. Metal fiber filters could offer additional designs to the GPF portfolio, which is currently dominated by ceramic wall-flow filters. However, knowledge on their performance as GPFs is still limited. In this study, modeling on backpressure and filtration efficiency of fibrous media was carried out to determine the basic design criteria (filtration area, filter thickness and size) for different target efficiencies and backpressures at given gas flow conditions. Filter media with different fiber sizes (8 - 17 μm) and porosities (80% - 95%) were evaluated using modeling to determine the influence of fiber size and porosity.
Journal Article

The Effects of CO, C2H4, and H2O on the NOx Storage Performance of Low Temperature NOx Adsorbers for Diesel Applications

2017-03-28
2017-01-0942
Model low temperature NOx adsorbers (LTNA) consisting of Pd on a ceria/zirconia washcoat on monoliths were evaluated for low temperature NOx storage under lean conditions to assess their potential for adsorbing the cold-start NOx emissions on a diesel engine during the period before the urea/SCR system becomes operational. A reactor-based transient test was performed with and without C2H4, CO/H2, and H2O to assess the effects of these species on the NOx storage performance. In the absence of C2H4 or CO/H2, H2O severely suppressed the NOx storage of these model LTNAs at temperatures below 100°C, presumably by blocking the storage sites. When C2H4 was included in the feedgas, H2O still suppressed the NOx storage below 100°C. However, the C2H4 significantly increased the NOx storage efficiency above 100°C, attributable to the formation of alkyl nitrites or alkyl nitrates on the catalyst.
Journal Article

The Development of Low Temperature Three-Way Catalysts for High Efficiency Gasoline Engines of the Future

2017-03-28
2017-01-0918
In anticipation that future gasoline engines will have improved fuel efficiency and therefore lower exhaust temperatures during low load operation, a project was initiated in 2014 to develop three-way catalysts (TWC) with improved activity at lower temperatures while maintaining the durability of current TWCs. This project is a collaboration between Ford Motor Company, Oak Ridge National Laboratory, and the University of Michigan and is funded by the U.S. Department of Energy. The ultimate goal is to show progress towards the USDRIVE goal of 90% conversion of hydrocarbons (HC), carbon monoxide (CO), and nitrogen oxides (NOx) at 150°C after high mileage aging. A reactor was set up at Ford to follow the catalyst testing protocols established by the USDRIVE ACEC tech team for evaluating catalysts for stoichiometric gasoline direct-injection (S-GDI) engines; this protocol specifies a stoichiometric blend of CO/H2, NO, C3H6, C2H4, C3H8, O2, H2O, and CO2 for the evaluations.
Journal Article

Lubricant-Derived Ash Impact on Gasoline Particulate Filter Performance

2016-04-05
2016-01-0942
The increasing use of gasoline direct injection (GDI) engines coupled with the implementation of new particulate matter (PM) and particle number (PN) emissions regulations requires new emissions control strategies. Gasoline particulate filters (GPFs) present one approach to reduce particle emissions. Although primarily composed of combustible material which may be removed through oxidation, particle also contains incombustible components or ash. Over the service life of the filter the accumulation of ash causes an increase in exhaust backpressure, and limits the useful life of the GPF. This study utilized an accelerated aging system to generate elevated ash levels by injecting lubricant oil with the gasoline fuel into a burner system. GPFs were aged to a series of levels representing filter life up to 150,000 miles (240,000 km). The impact of ash on the filter pressure drop and on its sensitivity to soot accumulation was investigated at specific ash levels.
Journal Article

Rapidly Pulsed Reductants in Diesel NOx Reduction by Lean NOx Traps: Effects of Mixing Uniformity and Reductant Type

2016-04-05
2016-01-0956
Lean NOx Traps (LNTs) are one type of lean NOx reduction technology typically used in smaller diesel passenger cars where urea-based Selective Catalytic Reduction (SCR) systems may be difficult to package . However, the performance of lean NOx traps (LNT) at temperatures above 400 C needs to be improved. The use of Rapidly Pulsed Reductants (RPR) is a process in which hydrocarbons are injected in rapid pulses ahead of a LNT in order to expand its operating window to higher temperatures and space velocities. This approach has also been called Di-Air (diesel NOx aftertreatment by adsorbed intermediate reductants) by Toyota. There is a vast parameter space which could be explored to maximize RPR performance and reduce the fuel penalty associated with injecting hydrocarbons. In this study, the mixing uniformity of the injected pulses, the type of reductant, and the concentration of pulsed reductant in the main flow were investigated.
Journal Article

TWC+LNT/SCR Systems for Satisfying Tier 2, Bin 2 Emission Standards on Lean-Burn Gasoline Engines

2015-04-14
2015-01-1006
A laboratory study was performed to assess the potential capability of TWC+LNT/SCR systems to satisfy the Tier 2, Bin 2 emission standards for lean-burn gasoline applications. It was assumed that the exhaust system would need a close-coupled (CC) TWC, an underbody (U/B) TWC, and a third U/B LNT/SCR converter to satisfy the emission standards on the FTP and US06 tests while allowing lean operation for improved fuel economy during select driving conditions. Target levels for HC, CO, and NOx during lean/rich cycling were established. Sizing studies were performed to determine the minimum LNT/SCR volume needed to satisfy the NOx target. The ability of the TWC to oxidize the HC during rich operation through steam reforming was crucial for satisfying the HC target.
Journal Article

Passive TWC+SCR Systems for Satisfying Tier 2, Bin 2 Emission Standards on Lean-Burn Gasoline Engines

2015-04-14
2015-01-1004
A laboratory study was performed to assess the potential capability of passive TWC+SCR systems to satisfy the Tier 2, Bin 2 emission standards for lean-burn gasoline applications. In this system, the TWC generates the NH3 for the SCR catalyst from the feedgas NOx during rich operation. Therefore, this approach benefits from high feedgas NOx during rich operation to generate high levels of NH3 quickly and low feedgas NOx during lean operation for a low rate of NH3 consumption. It was assumed that the exhaust system needed to include a close-coupled (CC) TWC, an underbody (U/B) TWC, and an U/B SCR converter to satisfy the emission standards during the FTP and US06 tests while allowing lean operation for improved fuel economy during select driving conditions. Target levels for HC, CO, and NOx during lean/rich cycling were established. With a 30 s lean/10 s rich cycle and 200 ppm NO lean, 1500 ppm NO rich and the equivalent of 3.3 L of SCR volume were required to satisfy the NOx target.
Technical Paper

Advanced Urea SCR System Study with a Light Duty Diesel Vehicle

2012-04-16
2012-01-0371
U.S. federal vehicle emission standards effective in 2007 require tight control of NOx and hydrocarbon emissions. For light-duty vehicles, the current standard of Tier 2 Bin 5 is about 0.07 g/mi NOx and 0.09 g/mi NMOG (non-methane organic gases) at 120,000 mi. However, the proposed future standard is 0.03 g/mi for NMOG + NOx (~SULEV30) at 150,000 mi. There is a significant improvement needed in catalyst system efficiencies for diesel vehicles to achieve the future standard, mainly during cold start. In this study, a less than 6000 lbs diesel truck equipped with an advanced urea Selective Catalytic Reduction (SCR) system was used to pursue lower tailpipe emissions with an emphasis on vehicle calibration and catalyst package. The calibration was tuned by optimizing exhaust gas recirculation (EGR) fuel injection and cold start strategy to generate desirable engine-out emissions balanced with reasonable temperatures.
Technical Paper

LNT+SCR Catalyst Systems Optimized for NOx Conversion on Diesel Applications

2011-04-12
2011-01-0305
A laboratory study was performed to assess the effectiveness of LNT+SCR systems for NOx control in lean exhaust. The effects of the catalyst system length and the spatial configuration of the LNT & SCR catalysts were evaluated for their effects on the NOx conversion, NH₃ yield, N₂O yield, and HC conversion. It was found that multi-zone catalyst architectures with four or eight alternating LNT and SCR catalyst zones had equivalent gross NOx conversion, lower NH₃ and N₂O yield, and significantly higher net conversion of NOx to N₂ than an all-LNT design or a standard LNT+SCR configuration, where all of the SCR volume is placed downstream of the LNT. The lower NH₃ emissions of the two multi-zone designs relative to the standard LNT+SCR design were attributed to the improved balance of NOx and NH₃ in the SCR zones.
Journal Article

The Effects of Sulfur Poisoning and Desulfation Temperature on the NOx Conversion of LNT+SCR Systems for Diesel Applications

2010-04-12
2010-01-0300
A laboratory study was performed to assess the effects of sulfur poisoning and desulfation temperature on the NO conversion of a LNT+(Cu/SCR) in-situ system. Four LNT+(Cu/SCR) systems were aged for 4.5 hours without sulfur at 600, 700, 750, and 800°C using A/F ratio modulations to represent 23K miles of desulfations at different temperatures. NO conversion tests were performed on the LNT alone and on the LNT+SCR system using a 60 s lean/5 s rich cycle. The catalysts were then sulfur-poisoned at 400°C and desulfated four times and re-evaluated on the 60/5 tests. This test sequence was repeated 3 more times to represent 100K miles of desulfations. After simulating 23K miles of desulfations, the Cu-based SCR catalysts improved the NO conversion of the LNT at low temperatures (e.g., 300°C), although the benefit decreased as the desulfation temperature increased from 600°C to 800°C.
Technical Paper

The Development of Advanced Urea-SCR Systems for Tier 2 Bin 5 and Beyond Diesel Vehicles

2010-04-12
2010-01-1183
An advanced diesel aftertreatment system utilizing Selective Catalytic Reduction (SCR) with urea for lean nitrogen oxides (NOx) control was tested on a 2.7L V6 Land Rover vehicle to demonstrate the capability of achieving Tier 2 Bin 5 and lower emission standards for light-duty trucks. SCR washcoat was applied to a diesel particulate filter (DPF) to perform NOx and particulate reduction simultaneously. Advanced SCR systems employed both traditional SCR catalysts and SCR-coated filters (SCRF) to improve the NOx reduction efficiency. The engine-out NOx level was adjusted by modifying the EGR (Exhaust Gas Recirculation) calibration. Cold start NOx performance was improved by SCR warm-up strategy and urea over injection. This study showed the advanced SCR system could tolerate higher NH₃ storage in the SCR catalyst, resulting in overall higher NOx conversion on the FTP-75 test cycle.
Journal Article

SCR Catalyst Systems Optimized for Lightoff and Steady-State Performance

2009-04-20
2009-01-0901
A laboratory study was performed to optimize a zoned configuration of an iron (Fe) SCR catalyst and a copper (Cu) SCR catalyst in order to provide high NOx conversion at lean A/F ratios over a broad range of temperature for diesel and lean-burn gasoline applications. With an optimized space velocity of 8,300 hr-1, a 67% (by volume) Fe section followed by a 33% Cu section provided at least 80% NOx conversion from approximately 230°C to 640°C when evaluated with 500 ppm NO and NH3. To improve the lean lightoff performance of the SCR catalyst system during a cold start, a Cu SCR catalyst that was 1/4 as long as the rear Cu SCR catalyst was placed in front of the Fe SCR catalyst. When evaluated with an excess of NH3 (NH3/NO ratio of 2.2), the Cu+Fe+Cu SCR system had significantly improved lightoff performance relative to the Fe+Cu SCR system, although the front Cu SCR catalyst did decrease the NOx conversion at temperatures above 475°C by oxidizing some of the NH3 to N2 or NO.
Journal Article

The Poisoning and Desulfation Characteristics of Iron and Copper SCR Catalysts

2009-04-20
2009-01-0900
A laboratory study was performed to assess the effects of SO2 poisoning on the NOx conversion of iron (Fe) and copper (Cu) SCR catalysts. Thermally aged samples of the catalysts were poisoned with SO2 under lean conditions. At various times during the poisonings, the samples were evaluated for NOx conversion with NO and NH3 using lean temperature ramps. The low temperature NOx conversions of both catalysts decreased by 10 to 20% after 1 to 4 hours of poisoning but were stable with continued exposure to the SO2. The poisoned Cu SCR catalyst could be desulfated repeatedly with 5 minutes of lean operation at 600°C. Initially, the poisoned Fe SCR catalyst required 5 minutes of lean operation at 750°C to recover its maximum NOx conversion.
Technical Paper

Cold Start Performance and Enhanced Thermal Durability of Vanadium SCR Catalysts

2009-04-20
2009-01-0625
For diesel applications, cold start accounts for a large amount of the total NOx emissions during a typical Federal Test Procedure (FTP) for light-duty vehicles and is a key focus for reducing NOx emissions. A common form of diesel NOx aftertreatment is selective catalytic reduction (SCR) technology. For cold start NOx improvement, the SCR catalyst would be best located as the first catalyst in the aftertreatment system; however, engine-out hydrocarbons and no diesel oxidation catalyst (DOC) upstream to generate an exotherm for desulfation can result in degraded SCR catalyst performance. Recent advances in vanadia-based SCR (V-SCR) catalyst technology have shown better low temperature NOx performance and improved thermal durability. Three V-SCR technologies were tested for their thermal durability and low-temperature NOx performance, and after 600°C aging, one technology showed low-temperature performance on par with state-of-the-art copper-zeolite SCR (Cu-SCR) technology.
Technical Paper

The Effects of SO2 and SO3 Poisoning on Cu/Zeolite SCR Catalysts

2009-04-20
2009-01-0898
Copper/zeolite catalysts are the leading urea SCR catalysts for NOx emission treatment in diesel applications. Sulfur poisoning directly impacts the overall SCR performance and is still a durability issue for Cu/zeolite SCR catalysts. Most studies on sulfur poisoning of Cu/zeolite SCR catalysts have been based on SO2 as the poisoning agent. It is important to investigate the relative poisoning effects of SO3, especially for systems with DOCs in front of Cu/zeolite SCR catalysts. It was observed that SCR activity was significantly reduced for samples poisoned by SO3 vs. those poisoned by SO2. The sulfur was released mainly as SO2 for both samples poisoned by SO2 and SO3. The temperatures and the magnitudes of released SO2 peaks however, were very different between the samples poisoned by SO2 vs. SO3. The results indicate that sulfur poisoning by SO2 and SO3 are not equivalent, with different poisoning mechanisms and impacts.
Journal Article

Sulfur Tolerance and DeSOx Studies on Diesel SCR Catalysts

2008-04-14
2008-01-1023
Base metal/zeolite catalysts, particularly containing copper and iron, are among the leading candidates for treatment of NOx emissions for diesel applications. Even with the use of ultra low sulfur fuel, sulfur poisoning is still a durability issue for base metal/zeolite SCR catalysts. In this study, the impact of sulfur poisoning on SCR activity and the stored sulfur removal effectiveness were investigated on several Cu and Fe/zeolite SCR catalysts after different thermal aging. The impact of sulfur was more significant on the Cu than on Fe/zeolite SCR catalysts for the NOx activity. It was found that the sensitivity of thermal aging status to the sulfur poisoning impact was different. The impact of sulfur on NOx activity changed with thermal aging on some catalysts, while it remained relatively the same for other catalysts. The most thermally durable SCR catalyst was not necessarily the most durable to sulfur poisoning.
Journal Article

Technical Advantages of Vanadium SCR Systems for Diesel NOx Control in Emerging Markets

2008-04-14
2008-01-1029
Selective catalytic reduction (SCR) is a promising technology for diesel aftertreatment to meet NOx emissions targets in several countries. In established markets such as the US and Europe, zeolite SCR systems are expected to be used due to their ability to survive the exhaust gas temperatures seen in an active diesel particulate filter regeneration. In emerging markets where the fuel sulfur level may be as high as 2000 parts per million, zeolite SCR catalysts may have durability issues. In these markets, low sulfur fuel is needed overall to meet emissions standards and to avoid high sulfate emissions, but the aftertreatment system must be durable to high sulfur levels because there is a risk of exposure to high sulfur fuel. Also, emissions standards may be met without a DPF in some applications, so that the exhaust system would not see temperatures of 600°C or higher.
X