Refine Your Search

Topic

Search Results

Standard

Glossary of Engine Cooling System Terms

2023-12-01
CURRENT
J1004_202312
The objective of this glossary is to establish uniform definitions of parts and terminology for engine cooling systems. Components included are all those through which engine coolant is circulated: water pump, engine oil cooler, transmission and other coolant-oil coolers, charge air coolers, core engine, thermostat, radiator, external coolant tanks, and lines connecting them.
Standard

Heavy-Duty Vehicle Cooling Test Procedures

2023-02-06
CURRENT
J1393_202302
The purpose of this SAE Recommended Practice is to establish a testing procedure to determine the performance capability of heavy-duty vehicle cooling systems to meet Original Equipment Manufacturer or end user thermal specifications to ensure long term reliable vehicle operations. The recommendations from the present document are intended for heavy-duty vehicles including, but not limited to, on- and off-highway trucks, buses, cranes, drill rigs, construction, forestry, and agricultural machines.
Standard

Test Method for Determining Power Consumption of Cooling Fan Drive Systems

2022-08-26
CURRENT
J1342_202208
The techniques outlined in this SAE Recommended Practice were developed as part of an overall program for determining and evaluating fuel consumption of heavy-duty trucks and buses, but it is applicable to off highway vehicles as well. It is recommended that the specific operating conditions be carefully reviewed on the basis of actual installation data. Cooling requirements are affected by all heat exchangers that are cooled by the fan drive system. These may include radiators, condensers, charge air coolers, oil coolers, and others. Because of the variation in size, shape, configuration, and mountings available in cooling fans and fan drive systems, specific test devices have not been included. Using known power/speed relationships for a given fan, this procedure can be used to calculate the fan drive system’s power consumption for cooling systems using the types of drives listed below. This power consumption may then be used in determining engine net power per SAE J1349.
Standard

Engine Cooling Fan Structural Analysis

2022-02-23
CURRENT
J1390_202202
Three levels of fan structural analysis are included in this practice: a Initial structural integrity. b In-vehicle testing. c Durability (laboratory) test methods. The initial structural integrity section describes analytical and test methods used to predict potential resonance and, therefore, possible fatigue accumulation. The in-vehicle (or machine) section enumerates the general procedure used to conduct a fan strain gage test. Various considerations that may affect the outcome of strain gage data have been described for the user of this procedure to adapt/discard depending on the particular application. The durability test methods section describes the detailed test procedures for a laboratory environment that may be used depending on type of fan, equipment availability, and end objective. The second and third levels build upon information derived from the previous level.
Standard

Oil Cooler Application Testing and Nomenclature

2021-12-13
CURRENT
J1468_202112
This SAE Recommended Practice is applicable to oil-to-air and oil-to-coolant oil coolers installed on mobile or stationary equipment and provides a glossary of oil cooler nomenclature. Such oil coolers may be used for the purpose of cooling automatic transmission fluid, hydraulic system oil, retarder system fluid, engine oil, etc. This document outlines the methods of procuring the test data to determine the operating characteristics of the oil cooling system and the interpretation of the results.
Standard

Test Method for Measuring Performance of Engine Cooling Fans

2019-09-30
CURRENT
J1339_201909
This SAE Recommended Practice is intended for use in testing and evaluating the approximate performance of engine-driven cooling fans. This performance would include flow, pressure, and power. This flow and pressure information is used to estimate the engine cooling performance. This power consumption is used to estimate net engine power per SAE J1349. The procedure also provides a general description of equipment necessary to measure the approximate fan performance. The test conditions in the procedure generally will not match those of the installation for which cooling and fuel consumption information is desired. The performance of a given fan depends on the geometric details of the installation, including the shroud and its clearance. These details should be duplicated in the test setup if accurate performance measurement is expected.
Standard

Glossary of Engine Cooling System Terms

2019-04-22
HISTORICAL
J1004_201904
The objective of this glossary is to establish uniform definitions of parts and terminology for engine cooling systems. Components included are all those through which engine coolant is circulated: water pump, engine oil cooler, transmission and other coolant-oil coolers, charge air coolers, core engine, thermostat, radiator, external coolant tanks, and lines connecting them.
Standard

Thermal Flow Control Valve Nomenclature and Application

2018-11-02
CURRENT
J3142_201811
The purpose of this SAE Information Report is to define common industry terminology and nomenclature relative to thermal flow control valves and to describe common thermal flow control valve applications in automotive, highway truck, mobile construction equipment, and industrial applications. This document is primarily directed at internal combustion engine or electric powered applications and the downstream systems to which power is provided, such as transmissions, hydraulics, air compression, etc. The information contained herein does not constitute an SAE Standard.
Standard

Radiator Nomenclature

2018-10-09
CURRENT
J631_201810
This SAE Recommended Practice documents nomenclature in common use for various types of radiator and radiator core construction, as well as for various radiator-related accessories.
Standard

Radiator Caps and Filler Necks

2018-04-05
HISTORICAL
J164_201804
This SAE Standard was developed primarily for passenger car and truck application, but may be used in marine, industrial, and similar applications.
Standard

Heavy Duty Vehicle Cooling Test Code

2017-12-12
HISTORICAL
J1393_201712
The purpose of this SAE Recommended Practice is to establish a testing procedure to determine the performance capability of heavy duty vehicle cooling systems to meet Original Equipment Manufacturer or end user thermal specifications to ensure long term reliable vehilcle operations. The recommendations from the present document are intended for heavy-duty vehicles including, but is not limited to, on- and off-highway trucks, buses, cranes, drill rigs, construction, forestry and agricultural machines.
Standard

Engine Cooling Fan Structural Analysis

2017-06-01
HISTORICAL
J1390_201706
Three levels of fan structural analysis are included in this practice: a Initial Structural Integrity b In-vehicle Testing c Durability (Laboratory) Test Methods The Initial Structural Integrity section describes analytical and test methods used to predict potential resonance and, therefore, possible fatigue accumulation. The In-vehicle (or machine) section enumerates the general procedure used to conduct a fan strain gage test. Various considerations that may affect the outcome of strain gage data have been described for the user of this procedure to adapt/discard depending on the particular application. The Durability Test Methods section describes the detailed test procedures for a laboratory environment that may be used depending on type of fan, equipment availability, and end objective. The second and third levels build upon information derived from the previous level.
Standard

Radiator Nomenclature

2013-11-07
HISTORICAL
J631_201311
This SAE Standard documents standard nomenclature in common use for various types of radiator and radiator core construction, as well as for various radiator-related accessories.
Standard

Heavy Duty Vehicle Cooling Test Code

2012-09-17
HISTORICAL
J1393_201209
This document supersedes SAE J819 - Engine Cooling System Field Test. The purpose of this SAE Recommended Practice is to establish a testing procedure to determine the performance capability of engine cooling systems, including charge air coolers, on heavy-duty vehicles with liquid-cooled internal combustion engines. The definition of heavy vehicles for this document includes, but is not limited to, on- and off-highway trucks, cranes, drill rigs, construction, forestry and agricultural machines. Vehicles equipped with side or rear-mounted radiators may require an alternate procedure of a towing dynamometer because of peculiar aerodynamics. Testing is generally conducted to determine compliance with cooling criteria established by the engine manufacturer or the end product user to meet a desired engine reliability goal.
X