Journal Article
Measurements of Oil Circulation Rate using Flow-through and Evacuated Type Sampling Cylinders for an Automotive Air Conditioning System
2023-04-11
2023-01-0138
In automotive air conditioning systems, the oil circulation rate (OCR) is known to affect performance at both the component and system levels. The OCR is the ratio of the mass of the oil in a representative sample of oil-refrigerant mixture from the system to the total mass of the sample taken during steady state operation. With the general industry trend towards low-OCR compressors, the OCR values of interest are getting smaller, and it is becoming increasingly important to acquire an accurate knowledge of OCR for proper system optimization. While there are different OCR measurement techniques available, they all require accurate calibration which is done using the ASHRAE Standard 41.4. The standard describes a sampling technique using an evacuated sampling cylinder with a dead end to draw a sample of oil-refrigerant mixture from the system liquid line.