Refine Your Search

Topic

Search Results

Standard

Ground Support Equipment Hydraulic Systems, Design and Installation, Recommended Practices for

2022-12-16
CURRENT
ARP4943A
This SAE Aerospace Recommended Practice (ARP) covers the design and installation requirements for hydraulic systems (up to 8000 psig [56 MPa]) for ground support equipment (GSE). This ARP is derived from AS5440, which provides hydraulic system requirements for aircraft. The recommendations herein are primarily intended for GSE that exchange hydraulic fluid with the aircraft, such as hydraulic service carts, rather than GSE with non-interfacing hydraulic systems. The GSE may be mobile, portable, or stationary.
Standard

Electric Baggage/Cargo Tractor

2022-03-28
CURRENT
ARP1804B
This SAE Aerospace Recommended Practice (ARP) outlines the design and performance requirements for a battery-powered electric tow tractor for the handling of baggage or cargo trailers in airline service. The use of “shall” in this document indicates a mandatory requirement. The use of “should” indicates a recommendation or that which is advised but not required.
Standard

Charger for Battery Powered Ground Support Equipment

2020-09-23
CURRENT
ARP1816D
This SAE Aerospace Recommended Practice (ARP) describes three general types of Ground Support Equipment (GSE) battery chargers. The battery charger typically requiring up to 8 hours to recharge a 100% discharged battery, hereafter called “Conventional Charger.” A charger, hereafter called “Opportunity Charger,” which has the ability to charge at a slightly faster rate than a conventional charger. A charger, hereafter called “Fast Charger,” which has the ability to charge at a much faster rate than a conventional charger. Recommendations that apply to all types will refer generically to “charger.”
Standard

Interface Protection - Ground Equipment to Aircraft

2019-03-28
CURRENT
ARP1558
This SAE Aerospace Recommended Practice (ARP) discusses damage to aircraft fuselages caused by ground equipment contact at servicing and recommends methods to be incorporated or considered in ground equipment design for protection against that damage.
Standard

Aural Protector, Sound

2012-01-24
CURRENT
AS23899A
This specification covers the design and performance requirements for one type of sound aural protector.
Standard

Electric Baggage/Cargo Tractor

2011-05-16
HISTORICAL
ARP1804A
This SAE Aerospace Recommended Practice (ARP) outlines the design and performance requirements for a battery-powered electric tow tractor for the handling of baggage or cargo trailers in airline service. The use of “shall” in this document indicates a mandatory requirement. The use of “should” indicates a recommendation or that which is advised but not required.
Standard

VEHICLE ELECTRICAL SYSTEMS

2007-08-29
HISTORICAL
AIR1336A
This SAE Aerospace Information Report (AIR) considers the following major areas: 1 Major components and their ratings 2 Selection criteria for optimum design balance for electrical systems 3 Effects of operating conditions and environment on both maintenance and life of components 4 Trouble signals—their diagnosis and cure
Standard

Aural Protector, Sound

1999-05-01
HISTORICAL
AS23899
This specification covers the design and performance requirements for one type of sound aural protector.
Standard

SOLID-STATE FREQUENCY CONVERTER 400 HERTZ, 3-PHASE OUTPUT

1989-09-01
HISTORICAL
ARP1940
This specification covers the requirements for solid-state frequency converters with 480 [or 380] V 3-phase, 60 [or 50] Hz input and 115/200 V, 3-phase, 400 Hz output capable of powering aircraft type loads requiring MIL-STD-704D quality power. The frequency converter shall be a self-contained unit suitable for the environment of intended use. Typical applications include dedicated use at passenger loading bridges (mounted under the bridge in telescoping bridge applications or fixed installation at base of stationary type loading bridges) with weatherproof enclosures or hangar/lab use where indoor fixed or portable units can be used.
Standard

GROUND ELECTRICAL POWER UNIT BRUSHLESS, SYNCHRONOUS, ELECTRIC MOTOR-DRIVEN 400 HERTZ, 3-PHASE OUTPUT

1985-08-01
HISTORICAL
ARP1480
This recommended practice outlines the general requirements of a continuous duty, electric motor-driven brushless alternator unit for supplying 400 Hz electrical power to high performance commercial transport aircraft. This specification is for a single motor-generator set with one or two outputs. The generator set will generate at the aircraft voltage of 115/200 volts. This unit may be used in a central system of small size or in hangar or electronic shop applications. Power characteristics of this unit at the receptacle will meet MIL-Standard-704 requirements. Other limits which are necessary to meet specific conditions must be specified by the purchaser.
Standard

GROUND EQUIPMENT REBUILD PROGRAM

1979-04-01
HISTORICAL
AIR1599
This AIR is intended to be concerned with fleet programs rather than programs for individual units. Technical and administrative considerations in developing an approach to a program will be suggested Organization of material possibly wanted in the form of a detailed specification for airline rebuilder communication is reviewed.
X