Refine Your Search

Topic

Search Results

Standard

Ground Support Equipment Hydraulic Systems, Design and Installation, Recommended Practices for

2022-12-16
CURRENT
ARP4943A
This SAE Aerospace Recommended Practice (ARP) covers the design and installation requirements for hydraulic systems (up to 8000 psig [56 MPa]) for ground support equipment (GSE). This ARP is derived from AS5440, which provides hydraulic system requirements for aircraft. The recommendations herein are primarily intended for GSE that exchange hydraulic fluid with the aircraft, such as hydraulic service carts, rather than GSE with non-interfacing hydraulic systems. The GSE may be mobile, portable, or stationary.
Standard

Charger for Battery Powered Ground Support Equipment

2020-09-23
CURRENT
ARP1816D
This SAE Aerospace Recommended Practice (ARP) describes three general types of Ground Support Equipment (GSE) battery chargers. The battery charger typically requiring up to 8 hours to recharge a 100% discharged battery, hereafter called “Conventional Charger.” A charger, hereafter called “Opportunity Charger,” which has the ability to charge at a slightly faster rate than a conventional charger. A charger, hereafter called “Fast Charger,” which has the ability to charge at a much faster rate than a conventional charger. Recommendations that apply to all types will refer generically to “charger.”
Standard

Interface Protection - Ground Equipment to Aircraft

2019-03-28
CURRENT
ARP1558
This SAE Aerospace Recommended Practice (ARP) discusses damage to aircraft fuselages caused by ground equipment contact at servicing and recommends methods to be incorporated or considered in ground equipment design for protection against that damage.
Standard

Cushion Tow Hitches Test

2012-12-05
CURRENT
AIR1353C
The main purpose of this test was to determine the application advantages of cushion tow hitches in comparison to the commonly used rigid tow hitch type fitted on heavy aircraft towing tractors. As diverse opinions emerged about its suitability since the introduction on the market of this new tow hitch type, it was intended to physically measure and evaluate the damping capability of this cushioned tow link when applied in practice.
Standard

Aural Protector, Sound

2012-01-24
CURRENT
AS23899A
This specification covers the design and performance requirements for one type of sound aural protector.
Standard

Ground Equipment - 400 Hertz Ground Power Performance Requirements

2011-01-14
HISTORICAL
ARP5015A
This SAE Aerospace Recommended Practice (ARP) covers the requirements for ground power equipment that supplies 115/200 V, 3-phase, 400 Hz output capable of powering aircraft type loads requiring MIL-STD-704E/DFS-400 quality power. All forms of ground power including mobile and fixed systems are addressed by this document. High voltage (270 V DC) systems are not included in this specification.
Standard

Charger for Battery Powered Ground Support Equipment

2009-06-29
HISTORICAL
ARP1816C
This SAE Aerospace Recommended Practice (ARP) describes two general types of Ground Support Equipment (GSE) battery chargers. The conventional industrial battery charger typically requiring up to 8 hours to recharge a 100% discharged battery, hereafter called “Conventional Charger”. The other type a fast battery charger typically used as an opportunity charger for ground support equipment, hereafter called “Fast Charger”. Recommendations that apply to both types will refer generically to “charger”.
Standard

Cushion Tow Hitches Test

2006-02-09
HISTORICAL
AIR1353B
The main purpose of this test was to determine the application advantages of cushion tow hitches in comparison to the commonly used rigid tow hitch type fitted on heavy aircraft towing tractors. As diverse opinions emerged about its suitability since the introduction on the market of this new tow hitch type, it was intended to physically measure and evaluate the damping capability of this cushioned tow link when applied in practice.
Standard

AIRCRAFT ENVIRONMENTAL FACTORS FOR DESIGN CONSIDERATION

2002-12-16
CURRENT
AIR1309
This AIR is presented in two parts - the first part, to alert the engineer with respect to the environmental factors which he might have to consider - the second part, as tabular data and figures to which he can refer with respect to a specific geographical location.
Standard

Aural Protector, Sound

1999-05-01
HISTORICAL
AS23899
This specification covers the design and performance requirements for one type of sound aural protector.
Standard

CHARGER FOR BATTERY POWERED GROUND SUPPORT EQUIPMENT

1996-07-01
HISTORICAL
ARP1816B
This SAE Aerospace Recommended Practice (ARP) describes an industrial battery charger, solid state type, hereafter called charger, for use in charging lead acid batteries in ground support equipment.
Standard

GROUND EQUIPMENT - 400 HERTZ GROUND POWER PERFORMANCE REQUIREMENTS

1996-06-01
HISTORICAL
ARP5015
This SAE Aerospace Recommended Practice (ARP) covers the requirements for ground power equipment that supplies 115/200 V, 3-phase, 400 Hz output capable of powering aircraft type loads requiring MIL-STD-704E/DFS-400 quality power. All forms of ground power including mobile and fixed systems are addressed by this document. High voltage (270 V DC) systems are not included in this specification.
Standard

CUSHION TOW HITCHES TEST

1992-08-18
HISTORICAL
AIR1353A
The main purpose of this test was to determine the application advantages of cushion tow hitches in comparison to the commonly used rigid tow hitch type fitted on heavy aircraft towing tractors. As diverse opinions emerged about its suitability since the introduction on the market of this new tow hitch type, it was intended to physically measure and evaluate the damping capability of this cushioned tow link when applied in practice.