Refine Your Search

Search Results

Viewing 1 to 10 of 10
Standard

Sensitization and Corrosion in Stainless Steel Filters

2014-02-06
CURRENT
AIR844B
This document reviews briefly the subject of woven metal screens. Conditions that can promote damaging corrosion in stainless steel filter screens are discussed and recommendations are listed for minimizing corrosion damage. This is a general document only; for specific applications it is suggested that the reader refer to the technical literature, and selected references listed below.
Standard

Secondary Filters for Fluid System Reliability

2012-09-24
CURRENT
AIR4057B
This SAE Aerospace Information Report (AIR) discusses the design choices and engineering trade-offs available to the system designer in the efficient selection and application of Last-Chance filters in contrast to main or primary system filters.
Standard

Sensitization and Corrosion in Stainless Steel Filters

2008-06-04
HISTORICAL
AIR844A
This document reviews briefly the subject of woven metal screens. Conditions that can promote damaging corrosion in stainless steel filter screens are discussed and recommendations are listed for minimizing corrosion damage. This is a general document only; for specific applications it is suggested that the reader refer to the technical literature, and selected references listed below.
Standard

Secondary Filters for Fluid System Reliability

2004-12-01
HISTORICAL
AIR4057A
This SAE Aerospace Information Report (AIR) discusses the design choices and engineering trade-offs available to the system designer in the efficient selection and application of Last-Chance filters in contrast to main or primary system filters.
Standard

Methods for Evaluating Cryogenic Filters

2002-03-23
HISTORICAL
ARP900A
The purpose of this test procedure is to present test methods that can be utilized to evaluate the filtration and operating characteristics of filters that will be utilized in a cryogenic system. The methods presented herein are intended to supplement standard filter testing specifications to allow evaluation of filter performance characteristics in areas that could be affected by extreme low temperatures. The test methods can be utilized to evaluate filters up to and including 60 gpm (230 lpm) capacity. If higher flow rate filters are to be evaluated in accordance with the test methods presented herein, it will be necessary to increase the system flow capacity and the size of effluent sampling system.
Standard

SECONDARY FILTERS FOR FLUID SYSTEM RELIABILITY

1994-05-01
HISTORICAL
AIR4057
It discusses the design choices and engineering trade-offs available to the system designer in the efficient selection and application of Last-Chance filters in contrast to main or primary system filters.
Standard

METHODS FOR EVALUATING CRYOGENIC FILTERS

1975-07-01
HISTORICAL
ARP900
The purpose of this test procedure is to present test methods that can be utilized to evaluate the filtration and operating characteristics of filters that will be utilized in a cryogenic system. The methods presented herein are intended to supplement standard filter testing specifications to allow evaluation of filter performance characteristics in areas that could be affected by extreme low temperatures. The test methods can be utilized to evaluate filters up to and including 60 GPM (330 liters per minute) capacity. If higher flow rate filters are to be evaluated in accordance with the test methods presented herein, it will be necessary to increase the system flow capacity and the size of effluent sampling system.
X