Refine Your Search

Topic

Search Results

Standard

Minimum General Standards for Oxygen Systems

2023-05-10
CURRENT
AS861C
This standard covers all types of oxygen breathing equipment used in non-military aircraft. It is intended that this standard supplements the requirements of the detail specification or drawings of specific components or assemblies (e.g., regulators, masks, cylinders, etc.). Where a conflict exists between this standard and detail specifications, detail specifications shall take precedence.
Standard

Minimum Standards for Valve, High Pressure Oxygen, Cylinder Shut Off, Manually Operated

2023-04-26
CURRENT
AS1066B
This standard covers all types of manually operated high pressure oxygen, cylinder shut off valves for use in commercial aircraft. It is intended that the valve shall be attached to a pressure cylinder storing oxygen under a nominal pressure of 12.76 MPa (1850 psig) at 21 °C (70 °F). Upon opening the valve, oxygen will be permitted to discharge from the storage cylinder to the valve outlet and to other downstream components of the oxygen system. It shall also be possible to recharge the cylinder through the valve.
Standard

Closed-Cycle Protective Breathing Devices

2023-01-26
CURRENT
AIR825/11A
Closed-cycle protective breathing apparatus, commonly referred to as rebreathers, or CCBA provide trained aircrew members or ground personnel with eye and respiratory protection from toxic atmospheres.
Standard

Reducers, Oxygen Pressure

2023-01-26
CURRENT
AS17852A
This specification covers the requirements for two types of oxygen pressure reducers.
Standard

Gaseous Oxygen and Oxygen Equipment, Introductory

2022-05-02
CURRENT
AIR825/3A
This SAE Aerospace Information Report provides a general discussion on gaseous breathing oxygen and oxygen equipment for use on commercial aircraft. Other types of oxygen systems are mentioned to assist in this discussion. For detailed information on systems other than gaseous, refer to the appropriate section of AIR825.
Standard

Oxygen Considerations for High Elevation Airport Operations (HEAO)

2021-08-26
CURRENT
AIR6829
This document covers information concerning the use of oxygen when flying into and out of high elevation airports for both pressurized and non-pressurized aircraft. Oxygen requirements for pressurized aircraft operating at high altitudes have for decades emphasized the potential failures that could lead to a loss of cabin pressurization coupled with the potential severe hypoxic hazard that decompressions represent. This document is intended to address the case where the relationship between cabin and ambient pressures are complicated by operations at high terrestrial altitudes. Operators who fly into these high-altitude airports should address the issues related to this environment because it carries the potential for insidious hypoxia and other conditions which can affect safety. It provides information to consider in developing operational procedures to address hypoxia concerns consistent with regulatory mandates.
Standard

Metabolic Simulator Testing Systems for Aviation Breathing Equipment

2021-08-11
CURRENT
ARP4259A
This Aerospace Recommended Practice (ARP) describes test equipment and methods used for testing closed cycle or semiclosed cycle breathing devices of short duration that are designed to operate with a high partial pressure of oxygen in the breathing circuit. It is intended to supplement ARP1109 and ARP1398 for applications involving closed cycle or semiclosed cycle breathing equipment which may be evaluated to the requirements of AS8031 and/or AS8047.
Standard

Gaseous Oxygen and Oxygen Equipment, Introductory

2021-08-11
HISTORICAL
AIR825/3
This Aerospace Information Report provides a general discussion on gaseous breathing oxygen and oxygen equipment for use on commercial aircraft. Other types of oxygen systems are mentioned to assist in this discussion. For detailed information on systems other than gaseous, reference the appropriate section of AIR825.
Standard

Location of Crew and Passenger Oxygen Masks, Portable Oxygen System, and Protective Breathing Equipment

2021-08-10
CURRENT
ARP6390
Various emergency situations may require the dispensing of oxygen to all occupants of aircraft during flight. During an emergency event, depending on the aircraft operational flight capability, all cabin occupants must be serviced by a mask presentation system connected to an operational oxygen source. Several regulations specify the functional characteristics and requirements of the oxygen systems for aircraft in support of different missions. These should be referred to for the exact functional performance requirements. It is not the intent of this document to ensure conformance with these regulations, but only to recommend general concepts for the location of the oxygen masks and oxygen system outlets for proper accessibility by the aircraft occupants, whether cabin occupants or crew members. Different requirements may apply when the mission of the pressurized aircraft or the operational altitude of the aircraft is not in excess of FL250.
Standard

Aircraft Oxygen Replenishment Coupling for Civil Transport Aircraft (Design Standard)

2021-03-09
WIP
AS1219B
This SAE Aerospace Design Standard defines a coupling, which is installed in a high pressure (1850 to 2000 psig) oxygen system of a civil transport aircraft for the purpose of mating to ground oxygen replenishment facilities. Dimensions developed from AND10089, Detail Specification Sheet for Fitting End, Design Standard, For Cone Connection.
Standard

Minimum Standard for Gaseous Oxygen Pressure Reducers

2020-05-27
CURRENT
AS1248B
This standard applies to pressure reducers for gaseous breathing oxygen systems and for all performance profiles without regard to particular inlet or outlet pressures. Attention is given, however, to construction requirements for reducers with maximum supply pressures to 2250 psig (155 bar) and reduced pressures of 50 to 150 psig (3.4 to 10.5 bar).
Standard

Aircraft Oxygen Replenishment Coupling for Civil Transport Aircraft (Design Standard)

2020-02-28
CURRENT
AS1219A
This SAE Aerospace Design Standard defines a coupling, which is installed in a high pressure (1850 to 2000 psig) oxygen system of a civil transport aircraft for the purpose of mating to ground oxygen replenishment facilities. Dimensions developed from AND10089, Detail Specification Sheet for Fitting End, Design Standard, For Cone Connection.
Standard

Crewmember Demand Oxygen Mask for Transport Category Aircraft

2019-08-14
CURRENT
AS8026B
This standard covers oxygen masks and breathing valves used with both panel mounted and mask mounted demand and pressure-demand oxygen regulators. Mask mounted oxygen regulators are covered under other standards, but when the mask mounted regulator incorporates an integral exhalation valve, the performance of this valve shall meet the requirements of this standard.
Standard

Oxygen Cylinder Installation Guide

2019-04-11
CURRENT
ARP5021B
This document provides guidance for oxygen cylinder installation on commerical aircraft based on airworthiness requirements, and methods practiced within aerospace industry. It covers considerations for oxygen systems from beginning of project phase up to production, maintenance, and servicing. The document is related to requirements of DOT-approved oxygen cylinders, as well to those designed and manufactured to standards of ISO 11119. However, its basic rules may also be applicable to new development pertaining to use of such equipment in an oxygen environment. For information regarding oxygen cylinders itself, also refer to AIR825/12.
Standard

Oxygen Flow Indication

2019-01-10
CURRENT
AS916C
This SAE Aerospace Standard (AS) defines the overall requirements applicable to oxygen flow indication as required by Airworthiness Requirements of CS/FAR 25.1449 to show that oxygen is being delivered to the dispensing equipment. Requirements of this document shall be applicable to any type of oxygen system technology and encompass “traditional” pneumatic devices, as well electric/electronic indication.
Standard

Continuous Flow Oxygen Regulator

2018-10-18
HISTORICAL
AS1197A
This standard covers regulators of the following types: Type I - Automatic Continuous Flow Type II - Adjustable Continuous Flow Type III - Pre-set Continuous Flow Class A - Cylinder Mounted Class B - Line Mounted Special - Composite Continuous Flow (Appendix)
Standard

Oxygen System Integration and Performance Precautions

2018-10-18
CURRENT
AIR825/12A
Oxygen system integration and performance precautions are in particularly dependent on applicable sections of airworthiness requirements per FAR/JAR 25. In this document information will be provided on common principles and good practices regarding design criteria, installation, manufacturing, safety aspects and system handling during maintenance and inspection.
X