Refine Your Search

Topic

Author

Search Results

Technical Paper

Characterization of Gaseous Emissions from Blended Plug-In Hybrid Electric Vehicles during High-Power Cold-Starts

2018-04-03
2018-01-0428
There is a distinct difference between plug-in hybrid electric vehicles in the market today. One key distinction that can be made is to classify a plug-in hybrid electric vehicle (PHEV) according to its operational behavior in charge depleting (CD) mode. Some PHEVs are capable of using the electric-only propulsion system to achieve all-electric operation for all driving conditions in CD mode, including full power performance. In contrast, some PHEVs, henceforth termed “blended PHEVs”, cannot satisfy the power requirements of all driving conditions with the electric-only propulsion system and occasionally utilize blended CD operation whereby it is necessary to blend the use of the internal combustion (IC) engine with the use of the electric motor(s) to help power the vehicle.
Technical Paper

Laboratory Testing of a Continuous Emissions Monitor for Trace Level Sulfur Dioxide

2016-04-05
2016-01-0986
The measurement of SO2 levels in vehicle exhaust can provide important information in understanding the relative contribution of sulfur and sulfate from fuel vs. oil source to PM. For this study, a differential optical absorption spectrometer (DOAS) that can measure SO2 down to 20 ppbV in real-time was built and evaluated. The DOAS consisted of an extractive sampling train, a cylindrical sampling cell with a single-path design to minimize cell volume, a spectrometer, and a deuterium lamp light source with a UVC range of ∼200-230 nanometer (nm). Laboratory tests showed detection limits were approximately in the range of 12 to 15 ppbV and showed good linearity over SO2 concentration ranges of 20 to 953 ppbV. Interference tests showed some interference by NO and by NH3, at levels of 300 ppmV and 16.6 ppmV, respectively.
Journal Article

Evaluation of PM Measurement Precision and the Quivalency of the Single and Three Filter Sampling Methods for LEV III FTP Standards

2016-01-15
2015-01-9045
Present motor vehicle particulate matter (PM) emission measurement regulations (Code of Federal Regulations (CFR) 40 Part 1065, 1066) require gravimetric determination of PM mass collected onto filter media from dilute exhaust. To improve the current sampling and measurement procedures for TIER 3 PM emissions standard of 3 mg/mile, CFR part 1066 adopted five alternative PM sampling options. One option of great interest is sampling the entire test using a single flow-weighed filter rather than the conventional three-filter (one filter per test phase) approach. The single filter method could lessen the time needed for gravimetric determination by reducing the quantity of filters used for a test and possibly reduce the uncertainty in gravimetric measurements, particularly at sub 1 mg/mile PM levels. This study evaluates the single filter and, to a limited extent, the 2-filter alternatives adopted in 40 CFR Part 1066.
Technical Paper

Evaluation of Gravimetric Method to Measure Light-Duty Vehicle Particulate Matter Emissions at Levels below One Milligram per Mile (1 mg/mile)

2014-04-01
2014-01-1571
The California Air Resources Board (CARB) adopted the Low Emission Vehicle (LEV) III regulations in January 2012, which lowered the particulate matter (PM) emissions standards for light-duty vehicles (LDVs) from 10 milligrams per mile (10 mg/mile) to 3 mg/mile beginning with model year (MY) 2017 and 1 mg/mile beginning with MY 2025. To confirm the ability to measure PM emissions below 1 mg/mile, a total of 23 LDVs (MY pre-2004 to 2009) were tested at CARB's Haagen-Smit Laboratory (HSL) (10 LDVs) and the United States Environmental Protection Agency's (US EPA) National Vehicle and Fuel Emissions Laboratory (NVEFL) (13 LDVs) using the federal test procedure (FTP) drive schedule. One LDV with PM emissions ranging from 0.6 - 0.8 mg/mile was tested at three CARB HSL test cells to investigate intra-lab and inter-lab variability. Reference, trip, and tunnel filter blanks were collected as part of routine quality control (QC) procedures.
Technical Paper

Developing the AC17 Efficiency Test for Mobile Air Conditioners

2013-04-08
2013-01-0569
Chrysler, Ford, General Motors, the U.S. Environmental Protection Agency (EPA) and the California Air Resources Board (CARB) have collaborated over the past two years to develop an efficiency test for mobile air conditioner (MAC) systems. Because the effect of efficiency differences between different MAC systems and different technologies is relatively small compared to overall vehicle fuel consumption, quantifying these differences has been challenging. The objective of this program was to develop a single dynamic test procedure that is capable of discerning small efficiency differences, and is generally representative of mobile air conditioner usage in the United States. The test was designed to be conducted in existing test facilities, using existing equipment, and within a sufficiently short time to fit standard test facility scheduling. Representative ambient climate conditions for the U.S. were chosen, as well as other test parameters, and a solar load was included.
Journal Article

Determination of the PEMS Measurement Allowance for PM Emissions Regulated Under the Heavy-Duty Diesel Engine In-Use Testing Program

2012-04-16
2012-01-1250
This paper summarizes the Heavy-Duty In-Use Testing (HDUIT) measurement allowance program for Particulate Matter Portable Emissions Measurement Systems (PM-PEMS). The measurement allowance program was designed to determine the incremental error between PM measurements using the laboratory constant volume sampler (CVS) filter method and in-use testing with a PEMS. Two independent PM-PEMS that included the Sensors Portable Particulate Measuring Device (PPMD) and the Horiba Transient Particulate Matter (TRPM) were used in this program. An additional instrument that included the AVL Micro Soot Sensor (MSS) was used in conjunction with the Sensors PPMD to be considered a PM-PEMS. A series of steady state and transient tests were performed in a 40 CFR Part 1065 compliant engine dynamometer test cell using a 2007 on-highway heavy-duty diesel engine to quantify the accuracy and precision of the PEMS in comparison with the CVS filter-based method.
Journal Article

Achieving an 80% GHG Reduction by 2050 in California's Passenger Vehicle Fleet: Implications for the ZEV Regulation

2010-10-19
2010-01-2306
In recognizing the potential for large, damaging impacts from climate change, California enacted Executive Order S-03-05, requiring a reduction in statewide greenhouse gas (GHG) emissions to 80% below 1990 levels by 2050. Given that the transportation light-duty vehicle (LDV) segment accounts for 28% of the state's GHG emissions today, it will be difficult to meet the 2050 goal unless a portfolio of near-zero carbon transportation solutions is pursued. Because it takes decades for a new propulsion system to capture a large fraction of the passenger vehicle market due to vehicle fleet turn-over rates, it is important to accelerate the introduction of these alternatives to ensure markets enter into early commercial volumes (10,000s) between 2015 and 2020. This report summarizes the results and conclusions of a modeling exercise that simulated GHG emissions from the LDV sector to 2050 in California.
Technical Paper

Particulate Mass and Number Emissions from Light-duty Low Emission Gasoline Vehicles

2010-04-12
2010-01-0795
Particulate matter (PM) emitted from light-duty gasoline powered vehicles is under increasing scrutiny due to potential adverse health effects and on ever increasing number of vehicles in the fleet. In this program, a group of California ULEV II and SULEV II certified light-duty gasoline vehicles were tested for PM mass and number emissions and compared with older model LEV I certified gasoline vehicles under the Federal Test Procedure (FTP) test cycle. PM mass and number emissions were collected from a Constant Volume Sampling (CVS) full dilution system. PM mass samples were collected with the gravimetric method. Filter conditioning and weighing procedures are in compliance with the Code of Federal Regulations (CFR) Part 1065. Total particles (solid and volatile) were measured using multiple fast response particle counting instruments including a TSI Engine Exhaust Particle Sizer (EEPS) and two Condensation Particle Counters (CPC).
Technical Paper

Detection of Gasoline Vehicles with Gross PM Emissions

2007-04-16
2007-01-1113
Light duty gasoline vehicles (LDGV) are estimated to contribute 40% of the total on-road mobile source tailpipe emissions of particulate matter (PM) in California. While considerable efforts have been made to reduce toxic diesel PM emissions going into the future, less emphasis has been placed on PM from LDGVs. The goals of this work were to characterize a small fleet of visibly smoking and high PM emitting LDGVs, to explore the potential PM-reduction benefits of Smog Check and of repairs, and to examine remote sensing devices (RSD) as a potential method for identifying high PM emitters in the in-use fleet. For this study, we recruited a fleet of eight vehicles covering a spectrum of PM emission levels. PM and criteria pollutant emissions were quantified on a dynamometer and CVS dilution tunnel system over the Unified Cycle using standard methods and real time PM instruments.
Technical Paper

Investigation of Ultrafine Particle Number Measurements from a Clean Diesel Truck Using the European PMP Protocol

2007-04-16
2007-01-1114
The sampling protocol proposed by the international PMP program for determination of particle emissions from clean light-duty vehicles was applied to the emissions from a California heavy-duty trap-equipped diesel truck. CARB is interested in developing opinions about the potential of this new European approach for emission determination and in exploring its utility for use in California. In this exercise, the use of various commercially available instruments for counting and sizing particles in the context of the PMP recommendations are explored. A single vehicle on a chassis dynamometer was exercised over steady-state and transient cycles. Multiple measurements of gaseous, mass, and particle emissions were collected in order to determine statistical significance. The PMP approach yielded particle emission measurements with higher precision and accuracy than the reference mass-based emission measurement.
Technical Paper

Transient Ultrafine Particle Emission Measurements with a New Fast Particle Aerosol Sizer for a Trap Equipped Diesel Truck

2005-10-24
2005-01-3800
The California Air Resources Board (CARB) has tested the utility of the Model 3090 Engine Exhaust Particle Sizer (EEPS™) by TSI in measuring pre- and post-trap particulate matter (PM) emissions from a medium-duty truck. Pre- and post-trap measurements are used to evaluate the effect of engine operation on PM emissions and trap effectiveness. Because of mounting evidence that ultrafine (UF) particles are harmful, regulatory agencies are investigating new and promising instrumentation for improved characterization of such particles in emissions. This is especially true for fast-response instruments that can be used to size-resolve real-time UF emissions from prominent sources such as diesel engines. The EEPS uses diffusion charging, electrical mobility segregation, and electrometers. It is designed for the number measurement of transient aerosols in the size range of 5.6 to 560 nm. It collects 10 measurements per second at a flow rate of 10 lpm.
Technical Paper

Durability of Low-Emissions Small Off-Road Engines

2004-09-27
2004-32-0058
The goal of the project was to reduce tailpipe-out hydrocarbon (HC) plus oxides of nitrogen (NOx) emissions to 50 percent or less of the current California Air Resources Board (CARB) useful life standard of 12 g/hp-hr for Class I engines, or 9 g/hp-hr for Class II engines. Low-emission engines were developed using three-way catalytic converters, passive secondary-air induction (SAI) systems, and in two cases, enleanment. Catalysts were integrated into the engine's mufflers, where feasible, to maintain a compact package. Due to the thermal sensitivity of these engines, carburetor calibrations were left unchanged in four of the six engines, at the stock rich settings. To enable HC oxidation under such rich conditions, a simple passive supplemental air injection system was developed. This system was then tuned to achieve the desired HC+NOx reduction.
Technical Paper

Emissions of HFC-134a from Light-Duty Vehicles in California

2004-05-10
2004-01-2256
The current refrigerant in mobile air conditioning (AC) systems, HFC-134a (also known as R134a), is a potent greenhouse gas (GHG) with a global-warming potential (GWP) of 1300. Its emissions from 2009 and subsequent model-year (MY) light-duty vehicles may be regulated under the terms of a law (Sec. 43108.5, Health and Safety Code) adopted in California in 2002. To support regulation development, we have estimated direct emissions of HFC-134a from vehicular AC systems in California by a novel, three-prong method that uses: 1) data on the consumption of HFC-134a by California commercial fleets, 2) surveys of vehicle owners on AC system repair incidence, and 3) data on repair incidence among California commercial fleet vehicles. Although these sources do not report direct emission rates of HFC-134a, the data reflect actual leakage integrated over long periods from vehicles in all stages of useful life.
Technical Paper

Development of the Direct Nonmethane Hydrocarbon Measurement Technique for Vehicle Testing

2003-03-03
2003-01-0390
The Automotive Industry/Government Emissions Research CRADA (AIGER) has been working to develop a new methodology for the direct determination of nonmethane hydrocarbons (DNMHC) in vehicle testing. This new measurement technique avoids the need for subtraction of a separately determined methane value from the total hydrocarbon measurement as is presently required by the Code of Federal Regulations. This paper will cover the historical aspects of the development program, which was initiated in 1993 and concluded in 2002. A fast, gas chromatographic (GC) column technology was selected and developed for the measurement of the nonmethane hydrocarbons directly, without any interference or correction being caused by the co-presence of sample methane. This new methodology chromatographically separates the methane from the nonmethane hydrocarbons, and then measures both the methane and the backflushed, total nonmethane hydrocarbons using standard flame ionization detection (FID).
Technical Paper

Interlaboratory Cross-Check of Heavy-Duty Vehicle Chassis Dynamometers

2002-10-21
2002-01-2879
Six laboratories capable of chassis-testing heavy-duty vehicles participated in a crosscheck program designed to compare emissions results from a Ford L-9000. The single-axle vehicle was shipped to each laboratory and tested through a series of UDDS and steady-state cycles. The resulting data were compared statistically using reproducibility and repeatability analyses. Although one lab produced some results that significantly differed from the other five, the remaining labs produced comparable results. TPM, CO and THC were the most variable while NOX and CO2 were most stable. Lab differences included atmospheric and environmental conditions, road-load curve application and drivers. Comparison of steady state and transient tests suggest that driver variability is not a major factor.
Technical Paper

Speciation of Organic Compounds from the Exhaust of Trucks and Buses: Effect of Fuel and After-Treatment on Vehicle Emission Profiles

2002-10-21
2002-01-2873
A study was performed in the spring of 2001 to chemically characterize exhaust emissions from trucks and buses fueled by various test fuels and operated with and without diesel particle filters. This study was part of a multi-year technology validation program designed to evaluate the emissions impact of ultra-low sulfur diesel fuels and passive diesel particle filters (DPF) in several different heavy-duty vehicle fleets operating in Southern California. The overall study of exhaust chemical composition included organic compounds, inorganic ions, individual elements, and particulate matter in various size-cuts. Detailed descriptions of the overall technology validation program and chemical speciation methodology have been provided in previous SAE publications (2002-01-0432 and 2002-01-0433).
Technical Paper

Evaluation of Durable Emission Controls for Large Nonroad SI Engines

2002-05-06
2002-01-1752
The Environmental Protection Agency (EPA) is developing emission standards for nonroad spark-ignition engines rated over 19 kW. Existing emission standards adopted by the California Air Resources Board for these engines were derived from emission testing with new engines, with an approximate adjustment applied to take deterioration into account. This paper describes subsequent testing with two LPG-fueled engines that had accumulated several thousand hours of operation with closed-loop control and three-way catalysts. These engines were removed from forklift trucks for characterization and optimization of emission levels. Emissions were measured over a wide range of steady-state points and several transient duty cycles. Optimized emission levels from the aged systems were generally below 1.5 g/hp-hr THC+NOx and 10 g/hp-hr CO.
Technical Paper

Performance of Partial Flow Sampling Systems Relative to Full Flow CVS for Determination of Particulate Emissions under Steady-State and Transient Diesel Engine Operation

2002-05-06
2002-01-1718
The use of a partial flow sampling system (PFSS) to measure nonroad steady-state diesel engine particulate matter (PM) emissions is a technique for certification approved by a number of regulatory agencies around the world including the US EPA. Recently, there have been proposals to change future nonroad tests to include testing over a nonroad transient cycle. PFSS units that can quantify PM over the transient cycle have also been discussed. The full flow constant volume sampling (CVS) technique has been the standard method for collecting PM under transient engine operation. It is expensive and requires large facilities as compared to a typical PFSS. Despite the need for a cheaper alternative to the CVS, there has been a concern regarding how well the PM measured using a PFSS compared to that measured by the CVS. In this study, three PFSS units, including AVL SPC, Horiba MDLT, and Sierra BG-2 were investigated in parallel with a full flow CVS.
Technical Paper

Evaluation of Fluorocarbon Polymer Bag Material for Near Zero Exhaust Emission Measurement

2001-09-24
2001-01-3535
When the California Air Resources Board (ARB) adopted automotive exhaust emission standards for Super Ultra-Low-Emission Vehicles (SULEV), new challenges were encountered for accurately measuring exhaust emissions. This is especially true for measuring NMOG emissions (NMHC and carbonyls) where the SULEV standard is 0.010 g/mi. One of the challenges in accurately measuring NMHC emissions is to find a clean sample bag material that has no or very low outgassing of hydrocarbons. Tedlar, the bag material commonly used for exhaust emission sampling, has been found to emit N,N- dimethylacetamide (DMAc), which interferes with hydrocarbon measurements and can contribute to significant error in SULEV hydrocarbon emission measurements. Several fluorocarbon materials were tested for hydrocarbon (HC) outgassing and carbon dioxide (CO2) permeation. The materials include Tedlar, Baked Tedlar, KynarFlex 2750, Baked KynarFlex 2800, Teflon FEP, TFM TFE, Tefzel, and Halar.
Technical Paper

CARB Evaporative Emissions Test Program

1999-10-25
1999-01-3528
In 1997 and 1998, the California Air Resources Board (CARB) conducted an extensive evaporative emissions test program to assess the feasibility of reducing evaporative emissions standards from the current 2 gram per test total hydrocarbon (THC) standard. Seven vehicles were tested and five modified in order to determine what emissions levels would be feasible. Emissions reductions of approximately 40% resulted from these modifications. The ARB also conducted studies of non-fuel background emissions and of emissions test variability.
X