Probing Spark Discharge Behavior in High-speed Cross-flows through Modeling and Experimentation

2020-04-14
2020-01-1120
This paper presents a combined numerical and experimental investigation of the characteristics of spark discharge in a spark-ignition engine. The main objective of this work is to gain insights into the spark discharge process and early flame kernel development. Experiments were conducted in an inert medium within an optically accessible constant-volume combustion vessel. The cross-flow motion in the vessel was generated using a previously developed shrouded fan. Numerical modeling was based on an existing discharge model in the literature developed by Kim and Anderson. However, this model is applicable to a limited range of gas pressures and flow fields. Therefore, the original model was evaluated and improved to predict the behavior of spark discharge at pressurized conditions up to 45 bar and high-speed cross-flows up to 32 m/s. To accomplish this goal, a parametric study on the spark channel resistance was conducted.
Technical Paper

Development of 4-Cylinder 2.0L Gasoline Engine Cooling System Using 3-D CAE

2019-04-02
2019-01-0156
To satisfy the global fuel economy restrictions getting stricter, various advanced cooling concepts, like active flow control strategy, cross-flow and fast warm-up, have been applied to the engine. Recently developed Hyundai’s next generation 4-cylinder 2.0L gasoline engine, also adopts several new cooling subsystems. This paper reviews how 3-D CAE analysis has been extensively used to evaluate cooling performance effectively from concept phase to pre-production phase. In the concept stage, the coolant flow in the water jacket of cylinder head and block was investigated to find out the best one among the proposed concepts and the further improvement of flow was also done by optimizing cylinder head gasket holes. Next, 3-D temperature simulation was conducted to satisfy the development criteria in the prototype stage before making initial test engines.
Technical Paper

An Innovative Electric Motor Cooling System for Hybrid Vehicles - Model and Test

2019-04-02
2019-01-1076
Enhanced electric motor performance in transportation vehicles can improve system reliability and durability over rigorous operating cycles. The design of innovative heat rejection strategies in electric motors can minimize cooling power consumption and associated noise generation while offering configuration flexibility. This study investigates an innovative electric motor cooling strategy through bench top thermal testing on an emulated electric motor. The system design includes passive (e.g., heat pipes) cooling as the primary heat rejection pathway with supplemental conventional cooling using a variable speed coolant pump and radiator fan(s). The integrated thermal structure, “cradle”, transfers heat from the motor shell towards an end plate for heat dissipation to the ambient surroundings or transmission to an external thermal bus to remote heat exchanger.
Technical Paper

Material NVH Convergence Technology for a Plastic Intercooler Pipe

2014-04-01
2014-01-1040
The main contribution of this paper is to employ a sound and vibration theory in order to develop a light and cost effective plastic intercooler pipe. The intercooler pipe was composed of two rubber hoses and one aluminum pipe mounted between an ACV (Air Control Valve) and an intercooler outlet. The engineering design concept is to incorporate low-vibration type bellows and an impedance-mismatched center pipe, which replaces the rubber hoses and aluminum pipe respectively. The bellows were designed to adapt powertrain movement for high vibration transmission loss to the intercooler outlet. Also, the impedance-mismatched center pipe was implemented to increase reflected wave by using relatively higher modulus than bellows part and applying a SeCo (Sequential Coextrusion) processing method.
Technical Paper

Combined Condensing Air-Conditioning System

2014-04-01
2014-01-0712
In order to improve the fuel consumption ratio of the vehicle, a great deal of research is being carried out to improve air-conditioning efficiency. Increasing the efficiency of the condenser is directly connected to the power consumption of the compressor. This paper describes an experimental method of using an additional water-cooled condenser to reduce power consumption and decrease discharge pressure of the air-conditioning system. First, the principle of a combined cooling (water + air) method was evaluated theoretically. Next, experimental proof was conducted with the additional water-cooled condenser. The shape and structure is similar to the plate type of the transmission oil cooler used in a radiator. Through a number of tests, it was found that it is possible is to reduce power consumption of compressor by decreasing discharge pressure.
Technical Paper

A Method for Precise Placement of Hose Models

2013-04-08
2013-01-0603
A method is presented for precise mounting of a hose model with any specified twist. Once mounting points and directions are specified, a hose of a specified length can be developed using discrete beams. A divide and conquer approach is employed to position, orient, decouple the free end of the hose model in a twist free state that is then twisted to a specified angle. The development of the kinematic elements necessary to do this is presented. Some Cosserat models have been shown to branch into multiple solutions while the method presented here has always converged to the minimum energy solution. The method for linking the hose model to other linkages is discussed as well one common error committed by users in implementing the link. In order to model the torsional properties of the hose, the torsional stiffness must be modified. A method for doing this using digital scans is discussed.
Technical Paper

Effects of Composite Sandwich Endplates on the Cold Start Characteristics of PEMFC

2010-04-12
2010-01-1091
End-plates are highly stiff plates that hold together the components composing a fuel cell stack, i.e. Membrane Electrode Assemblies (MEAs), Gas Distribution Layers (GDLs) and bipolar plates, offering sufficient contact pressure between them. The proper contact pressure is required not only to improve energy efficiency of a stack by decreasing ohmic loss but also to prevent leakage of fluids such as hydrogen, air, or coolant. When a fuel cell starts in cold environment, heat generated in a fuel cell stack as a result of electrochemical reactions should not be used much to increase the temperature of endplates but to melt ice inside the stack to prevent ice-blocking and to increase the temperature near the three-phase-boundary on MEAs. However, to satisfy the high stiffness required, massive metallic endplates have been used despite their inferior thermal characteristics: high thermal conductivity and large thermal inertia.
Technical Paper

An Efficient IC Engine Conjugate Heat Transfer Calculation for Cooling System Design

2007-04-16
2007-01-0147
This study focuses on how to predict hot spots of one of the cylinders of a V8 5.4 L FORD engine running at full load. The KIVA code with conjugate heat transfer capability to simulate the fast transient heat transfer process between the gas and the solid phases has been developed at the Michigan Technological University and will be used in this study. Liquid coolant flow was simulated using FLUENT and will be used as a boundary condition to account for the heat loss to the cooling fluid. In the first step of calculation, the coupling between the gas and the solid phases will be solved using the KIVA code. A 3D transient wall heat flux at the gas-solid interface is then compiled and used along with the heat loss information from the FLUENT data to obtain the temperature distribution for the engine metal components, such as cylinder wall, cylinder head, etc.
Technical Paper

A Transient Heat Transfer System for Research Engines

2007-04-16
2007-01-0975
An ongoing goal of the Powertrain Control Research Laboratory (PCRL) at the University of Wisconsin-Madison has been to expand and improve the ability of the single cylinder internal combustion research engine to represent its multi-cylinder engine counterpart. To date, the PCRL single cylinder engine test system is able to replicate both the rotational dynamics (SAE #2004-01-0305) and intake manifold dynamics (SAE #2006-01-1074) of a multi cylinder engine using a single cylinder research engine. Another area of interest is the replication of multi-cylinder engine cold start emissions data with a single-cylinder engine test system. For this replication to occur, the single-cylinder engine must experience heat transfer to the engine coolant as if it were part of a multi-cylinder engine, in addition to the other multi-cylinder engine transient effects.
Technical Paper

Extreme Field Test for Organic Additive Coolant Technology

2005-11-01
2005-01-3579
Field testing of an extended life coolant technology in Class 8 trucks, equipped with Caterpillar C-12 engines revealed excellent coolant life with negligible inhibitor depletion to 400,000 miles with no refortification and no coolant top-off. In separate evaluations in Caterpillar 3406E equipped trucks, extended corrosion protection and component durability were established out to 700,000 miles, without the need for refortification other than top-off.
Technical Paper

Development of the Enhanced Vehicle and Engine Cooling System Simulation and Application to Active Cooling Control

2005-04-11
2005-01-0697
The increasing complexity of vehicle engine cooling systems results in additional system interactions. Design and evaluation of such systems and related interactions requires a fully coupled detailed engine and cooling system model. The Vehicle Engine Cooling System Simulation (VECSS) developed at Michigan Technological University was enhanced by linking with GT-POWER for the engine/cycle analysis model. Enhanced VECSS (E-VECSS) predicts the effects of cooling system performance on engine performance including accessory power and fuel conversion efficiency. Along with the engine cycle, modeled components include the engine manifolds, turbocharger, radiator, charge-air-cooler, engine oil circuit, oil cooler, cab heater, coolant pump, thermostat, and fan. This tool was then applied to develop and simulate an actively controlled electric cooling system for a 12.7 liter diesel engine.
Technical Paper

A Controlled EGR Cooling System for Heavy Duty Diesel Applications Using the Vehicle Engine Cooling System Simulation

2002-03-04
2002-01-0076
In order to comply with 2002 EPA emissions regulations, cooled exhaust gas recirculation (EGR) will be used by heavy duty (HD) diesel engine manufacturers as the primary means to reduce emissions of nitrogen oxides (NOx). A feedforward controlled EGR cooling system with a secondary electric water pump and proportional-integral-derivative (PID) feedback has been designed to cool the recirculated exhaust gas in order to better realize the benefits of EGR without overcooling the exhaust gas since overcooling leads to the fouling of the EGR cooler with acidic residues. A system without a variable controlled coolant flow rate is not able to achieve these goals because the exhaust temperature and the EGR schedule vary significantly, especially under transient and warm-up operating conditions. Simulation results presented in this paper have been determined using the Vehicle Engine Cooling System Simulation (VECSS) software, which has been developed and validated using actual engine data.
Technical Paper

The Role of Carboxylate-Based Coolants in Cast Iron Corrosion Protection

2001-03-05
2001-01-1184
Nitrites have long been added to heavy-duty coolant to inhibit iron cylinder liner corrosion initiated by cavitation. However, in heavy-duty use, nitrites deplete from the coolant, which then must be refortified using supplemental coolant additives (SCA's). Recently, carboxylates have also been found to provide excellent cylinder liner protection in heavy-duty application. Unlike nitrites, carboxylate inhibitors deplete slowly and thus do not require continual refortification with SCA's. In the present paper laboratory aging experiments shed light on the mechanism of cylinder liner protection by these inhibitors. The performance of carboxylates, nitrites and mixtures of the two inhibitors are compared. Results correlate well with previously published fleet data. Specifically, rapid nitrite and slow carboxylate depletion are observed. More importantly, when nitrite and carboxylates are used in combination, nitrite depletion is repressed while carboxylates deplete at a very slow rate.
Technical Paper

Solder Protection with Extended Life, Carboxylate-Based Coolants

2000-06-19
2000-01-1979
Silicate-free, carboxylate based technology as typified by Texaco Extended Life Coolant (TELC) and Caterpillar Extended Life Coolant (ELC), both meeting Caterpillar's EC-1 Coolant Specification, offer excellent corrosion protection for commercial lead solders commonly used in the fabrication of copper/brass radiators and heater cores throughout the trucking industry. Results of laboratory testing using solders from commercial radiators manufacturers and extensive field coolant analysis compare extended life technology with the popular conventional coolant technologies. In the laboratory, the effect of coolant concentration on solder protection is explored using the glassware corrosion test, ASTM D-1384. At concentrations ranging from 33% up to 75% the carboxylate technology offers comparable to superior protection when compared to the popular heavy-duty conventional coolant containing silicates and phosphates.
Technical Paper

In search of SULEV-compliant THC emission reduction technologies

2000-06-12
2000-05-0298
This paper describes the development of THC reduction technologies compliant with SULEV regulations. Technologies embodied by the developmental work include improvement of fuel spay atomization, quick warm-up through coolant control shut off, and acceleration of fuel atomization for the fast rise of cylinder head temp inside the water jacket as well as the improvement of combustion state. The technologies likewise entail reduced HC while operating in lean A/F condition during engine warm-up with the cold lean-burn technology, individual cylinder A/F control for improvement of catalytic converting efficiency, aftertreatment such as thin-wall catalyst, HC absorber and EHC and etc., through vehicle application evaluation in cold start. We carried out an experimental as well as a practical study against SULEV regulations, and the feasibility of adopting these items in vehicle was likewise investigated.
Technical Paper

Friction Losses in Multi-Cylinder Diesel Engines

2000-03-06
2000-01-0921
This paper presents a global friction model of a diesel engine. The model accounts for the individual contributions of the main components of the mechanical losses and the influence of specific design and operating parameters on the mechanical losses. The main components considered in the model are: the piston-ring assembly, the valve train, the bearings and auxiliaries (injection pump, oil pump and coolant pump). For each of these components, the model was developed based on geometric parameters, operating conditions and the physics governing the friction. The individual models were assembled in a global friction model of a multicylinder diesel engine, and a computer code was developed to simulate the total mechanical losses of the engine. The experimental validation of the model was obtained by comparing the simulated crankshaft's speed variation with the instantaneous speed measured by a shaft encoder.
Technical Paper

The Vehicle Engine Cooling System Simulation Part 1 - Model Development

1999-03-01
1999-01-0240
The Vehicle Engine Cooling System Simulation (VECSS) computer code has been developed at the Michigan Technological University to simulate the thermal response of the cooling system of an on-highway heavy duty diesel powered truck under steady and transient operation. This code includes an engine cycle analysis program along with various components for the four main fluid circuits for cooling air, cooling water, cooling oil, and intake air, all evaluated simultaneously. The code predicts the operation of the response of the cooling circuit, oil circuit, and the engine compartment air flow when the VECSS is operated using driving cycle data of vehicle speed, engine speed, and fuel flow rate for a given ambient temperature, pressure and relative humidity.
Technical Paper

Performance of Organic Acid Based Coolants in Heavy Duty Applications

1996-02-01
960644
Coolant formulations based on organic acid corrosion inhibitor technology have been tested in over 180 heavy duty engines for a total of more than 50 million kilometers. This testing has been used to document long life coolant performance in various engine types from four major engine manufacturers. Inspections of engines using organic acid based coolant (with no supplemental coolant additive) for up to 610,000 kilometers showed excellent protection of metal engine components. Improved protection was observed against cylinder liner, water pump, and aluminum spacer deck corrosion. In addition, data accumulated from this testing were used to develop depletion rate curves for long life coolant corrosion inhibitors, including tolyltriazole and nitrite. Nitrite was observed to deplete less rapidly in long life coolants than in conventional formulations.
Technical Paper

A Bench Test Procedure for Evaluating the Cylinder Liner Pitting Protection Performance of Engine Coolant Additives for Heavy Duty Diesel Engine Applications

1996-02-01
960879
Evaluations of the liner pitting protection performance provided by engine coolant corrosion inhibitors and supplemental coolant additives have presented many problems. Current practice involves the use of full scale engine tests to show that engine coolant inhibitors provide sufficient liner pitting protection. These are too time-consuming and expensive to use as the basis for industry-wide specifications. Ultrasonic vibratory test rigs have been used for screening purposes in individual labs, but these have suffered from poor reproducibility and insufficient additive differentiation. A new test procedure has been developed that reduces these problems. The new procedure compares candidate formulations against a good and bad reference fluid to reduce the concern for problems with calibration and equipment variability. Cast iron test coupons with well-defined microstructure and processing requirements significantly reduce test variability.
Technical Paper

Development of Electronic Fan Control Systems

1994-09-01
941765
Engine cooling fan systems for off-highway machinery require a significant amount of horsepower and contribute to the overall noise level of the machine. Reducing fan speed in times of low cooling demand provides a means to reduce vehicle noise levels and divert engine horsepower from the fan to do productive work. The fan must, however, continue to provide adequate airflow when demanded by the cooling system. Electronic fan controls that modulate fan speed to meet changing cooling system requirements provide the above advantages.