Technical Paper
Evaluation of Partial Flow Dilution Methodology for Light Duty Particulate Mass Measurement
2013-04-08
2013-01-1567
Two different implementations of Partial Flow Dilution (PFD) methodology designed for gravimetric particulate matter (PM) sampling are evaluated for applicability to light-duty chassis emissions testing. Filter PM measurements were collected and compared to constant volume sampler (CVS) full dilution tunnel PM filter measurements and other real-time PM measurement technologies, using gasoline vehicles generating a range of 0.1 to 10.0 mg/mile PM. Exhaust samples were collected for each phase of the Federal Test Procedure (FTP-75) with a fourth filter sample collected for the US06 supplemental cycle. Both PFDs satisfactorily met proportionality criteria for conventional combustion engines, but some improvements are needed for hybrid electric vehicles (HEVs). The PM mass collected scaled linearly with the CVS tunnel samples, with slopes of 1.03 and 0.74 for the two PFDs.