Refine Your Search

Topic

Search Results

Viewing 1 to 16 of 16
Technical Paper

Monitoring Pre-Combustion Event Markers by Heating Electrical Wires

2009-07-12
2009-01-2543
Simultaneous measurements were made for particle releases and off-gassing products produced by heating electrical wires. The wire samples in these experiments were heated to selected temperatures in a heating chamber and responses to vapor releases were recorded by the JPL Electronic Nose (ENose) and an Industrial Scientific ITX gas-monitor; particles released were detected by a TSI P-Trak particle counter. The temperature range considered for the experiment is room temperature (24−26°C) to 500 °C. The results were analyzed by overlapping responses from the ENose, ITX gas sensors and P-Trak, to understand the events (particle release/off-gassing) and sequence of events as a function of temperature and to determine qualitatively whether ENose may be used to detect pre-combustion event markers.
Journal Article

Start-Up Characteristics and Gravity Effects on a Medium/High-Lift Heat Pump using Advanced Hybrid Loop Technology

2008-06-29
2008-01-1959
Thermal characterization was performed on a vapor compression heat pump using a novel, hybrid two phase loop design. Previous work on this technology has demonstrated its ability to provide passive phase separation and flow control based on capillary action. This provides high quality vapor to the compressor without relying on gravity-based phase separation or other active devices. This paper describes the subsequent work done to characterize evaporator performance under various startup scenarios, tilt angles, and heat loads. The use of a thermal expansion valve as a method to regulate operation was investigated. The effect of past history of use on startup behavior was also studied. Testing under various tilt angles showed evaporator performance to be affected by both adverse and favorable tilts for the given compressor. And depending on the distribution of liquid in the system upon startup, markedly different performance can result for the same system settings and heat loads.
Journal Article

Off-Gassing and Particle Release by Heated Polymeric Materials

2008-06-29
2008-01-2090
Polymers are one of the major constituents in electrical components. A study investigating pre-combustion off-gassing and particle release by polymeric materials over a range of temperatures can provide an understanding of thermal degradation prior to failure which may result in a fire hazard. In this work, we report simultaneous measurements of pre-combustion vapor and particle release by heated polymeric materials. The polymer materials considered for the current study are silicone and Kapton. The polymer samples were heated over the range 20 to 400°C. Response to vapor releases were recorded using the JPL Electronic Nose (ENose) and Industrial Scientific's ITX gas monitor configured to detect hydrogen chloride (HCl), carbon monoxide (CO) and hydrogen cyanide (HCN). Particle release was monitored using a TSI P-TRAK particle counter.
Technical Paper

Results from the Vehicle Cabin Atmosphere Monitor: A Miniature Gas Chromatograph/Mass Spectrometer for Trace Contamination Monitoring on the ISS and Orion

2008-01-29
2008-01-2045
Progress on the delivery of the Vehicle Cabin Atmosphere Monitor (VCAM) is reported. VCAM is an autonomous trace-species detector to be used aboard the International Space Station (ISS) for atmospheric analysis. The instrument is based on a low-mass, low-power miniature preconcentrator, gas chromatograph, and Paul ion trap mass spectrometer (PCGC/MS) capable of measuring volatile constituents in a space vehicle or planetary outpost at sub-ppm levels. VCAM detects and quantifies 40 target compounds at their 180-day Spacecraft Maximum Allowable Concentration (SMAC) levels. It is designed to operate autonomously, maintenance-free, with a self-contained carrier and calibration gas supplies sufficient for a one-year lifetime. Two flight units will be delivered for operation in the ISS EXPRESS rack.
Technical Paper

Development of the Surface Thermal Environment for the Mars Scout Phoenix Mission

2007-07-09
2007-01-3239
Phoenix is NASA's first Mars Scouts Mission that will place a soft-lander on the Martian surface at a high northern latitude. Much of the Mars surface environmental flight data from landed missions pertains to the near-equatorial regions. However, orbital observations have yielded very useful data about the surface environment. These data along with a simple, but highly effective one-dimensional atmospheric model was used to develop the Phoenix surface thermal environment. As candidate landing sites were identified, parametric studies including statistical variations were conducted to prescribe minimum nighttime and maximum daytime temperature design Sols (a Martian day). Atmospheric effects such as clouds and ice were considered. Finally, recent candidate landing site imaging conducted by the Mars Reconnaissance Orbiter revealed that the prime site contained a much higher rock density than first thought.
Technical Paper

Overview of the Vehicle Cabin Atmosphere Monitor, a Miniature Gas Chromatograph/Mass Spectrometer for Trace Contamination Monitoring on the ISS and CEV

2007-07-09
2007-01-3150
Work is underway to deliver an instrument for analysis of the atmosphere aboard the International Space Station. The Vehicle Cabin Atmosphere Monitor (VCAM) is based on a low-mass, low-power miniature preconcentrator gas chromatograph/mass spectrometer (PCGC/MS) capable of providing sub-ppm measurements of volatile constituents in a space vehicle or outpost. VCAM is designed to operate autonomously, maintenance-free, once per day, with its own carrier and calibration gas supplies sufficient for a one-year lifetime. VCAM performance is sufficient to detect and identify 90% of the target compounds specified at their 180-day Spacecraft Maximum Allowable Concentration (SMAC) levels. The flight units will be delivered in mid-2008 and be operated in the ISS EXPRESS rack.
Technical Paper

The Thermal Design Evolution of the Phoenix Robotic Arm

2006-07-17
2006-01-2033
Phoenix, NASA's first Mars Scouts mission, will be launched in 2007 and will soft-land inside the Martian Arctic Circle, between north 65° and 72° North latitude, in 2008 to study the water history and to search for habitable zones. Similar to the IDD (Instrument Deployment Device) on the Mars Exploration Rovers (MER), Phoenix has a Robotic Arm (RA) which is equipped with a scoop to dig into the icy soil and to deliver the soil samples to instruments for scientific observations and measurements. As with MER, the actuators and the bearings of the Phoenix RA in a non-operating condition can survive the cold Martian night without any electrical power or any thermal insulation. The RA actuators have a minimum operating allowable flight temperature (AFT) limit of -55°C, so, warm-up heaters are required to bring the temperatures of all the RA actuators above the operating AFT limit prior to early morning operation.
Technical Paper

Mechanically Pumped Fluid Loop Technologies for Thermal Control of Future Mars Rovers

2006-07-17
2006-01-2035
Future planetary science missions planned for Mars are expected to be more complex and thermally challenging than any of the previous missions. For future rovers, the operational parameters such as landing site latitudes, mission life, distance traversed, and rover thermal energy to be managed will be significantly higher (two to five times) than the previous missions. It is a very challenging problem to provide an effective thermal control for the future rovers using traditional passive thermal control technologies. Recent investigations at the Jet Propulsion Laboratory (JPL) have shown that mechanical pump based fluid loops provide a robust and effective thermal control system needed for these future rovers. Mechanical pump based fluid loop (MPFL) technologies are currently being developed at JPL for use on such rovers. These fluid loops are planned for use during spacecraft cruise from earth to Mars and also on the Martian surface operations.
Technical Paper

The Applicability of Past Innovative Concepts to the Technology for New Extremely Large Space Antenna/Telescope Structures

2006-07-17
2006-01-2063
Early development of concepts for space structures up to 1000 meters in size was initiated in the early 1960's and carried through the 1970's. The enabling technologies were self-deployables, on-orbit assembly, and on-orbit manufacturing. Because of the lack of interest due to the astronomical cost associated with advancing the on-orbit assembly and manufacturing technologies, only self-deployable concepts were subsequently pursued. However, for over 50 years, potential users of deployable antennas for radar, radiometers, planar arrays, VLBF and others, are still interested and constantly revising the requirements for larger and higher precision structures. This trend persists today. An excellent example of this trend is the current DARPA/SPO ISAT Program that applies self-deployable structures technology to a 300 meter long active planar array radar antenna. This ongoing program has created a rare opportunity for innovative advancement of state-of-the-art concepts.
Technical Paper

Expanding the Analyte Set of the JPL Electronic Nose to Include Inorganic Species

2005-07-11
2005-01-2880
An array-based sensing system based on 32 polymer/carbon composite conductometric sensors is under development at JPL. Until the present phase of development, the analyte set has focused on organic compounds (common solvents) and a few selected inorganic compounds, notably ammonia and hydrazine. The present phase of JPL ENose development has added two inorganics to the analyte set: mercury and sulfur dioxide. Through models of sensor-analyte response developed under this program coupled with a literature survey, approaches to including these analytes in the ENose target set have been determined.
Technical Paper

Mid-IR Semiconductor Lasers for Chemical Sensing

2003-07-07
2003-01-2551
The development of mid-IR semiconductor diode lasers based on type-II interband cascade structures is presented. How these diode lasers can be developed to meet the requirements in chemical sensing applications is discussed.
Technical Paper

Trace Gas Analyzer for Extra-Vehicular Activity

2001-07-09
2001-01-2405
The Trace Gas Analyzer (TGA, Figure 1) is a self-contained, battery-powered mass spectrometer that is designed for use by astronauts during extravehicular activities (EVA) on the International Space Station (ISS). The TGA contains a miniature quadrupole mass spectrometer array (QMSA) that determines the partial pressures of ammonia, hydrazines, nitrogen, and oxygen. The QMSA ionizes the ambient gas mixture and analyzes the component species according to their charge-to-mass ratio. The QMSA and its electronics were designed, developed, and tested by the Jet Propulsion Laboratory (1,2). Oceaneering Space Systems supported JPL in QMSA detector development by performing 3D computer for optimal volumetric integration, and by performing stress and thermal analyses to parameterize environmental performance.
Technical Paper

Fabrication of laterally coupled InGaAsSb-GaSb-AlGaAsSb DFB laser structures

2000-07-10
2000-01-2305
The development of tunable diode laser systems in the 2 - 5 μm spectral region will have numerous applications for trace gas detection. To date, the development of such systems has been hampered by the difficulties of epitaxial growth, and device processing in the case of the Sb-based materials system. One of the compounding factors in this materials system is the use of aluminum containing compounds in the laser diode cladding layers. This makes the regrowth steps used in traditional lasers very difficult. As an alternative approach we are developing laterally coupled antimonide based lasers structures that do not require the regrowth steps. In this paper, the materials growth, device processing and development of the necessary drive electronics for an antimony based tunable diode laser system are discussed.
Technical Paper

A Miniature Quadrupole Mass Spectrometer Array and GC For Space Flight: Astronaut EVA and Cabin-Air Monitoring

2000-07-10
2000-01-2300
A miniature quadrupole mass spectrometer array and gas chromatograph have been designed and built for NASA flight missions. Without the gas chromatograph the mass spectrometer is to be used for detection, by astronauts in EVA, of N2, O2, the hydrazines, and NH3 leaks in the hull of the International Space Station, and of adsorbed hydrazines on the astronauts’ suits. The fully-adapted astronaut system, with all software and visual readout, is called the Trace Gas Analyzer. When interfaced with the miniature gas chromatographic system, the mass spectrometer will be useful for a variety of NASA missions involving more complex gas mixtures. The missions include planetary exploration (to Venus, Europa, Titan, etc.), as well as cabin-air monitoring for long-duration human flight to the Moon, Mars, and beyond.
Technical Paper

Slow Reversible and Quasi-Reversible Performance Changes in AMTEC Electrodes and Electrolytes

1999-08-02
1999-01-2705
This paper reports several slow reversible and quasi-reversible processes which occur in the porous electrode/solid electrolyte combination at AMTEC operating temperatures. These processes help to elucidate the evolution of the electrode and electrolyte characteristics with time. They also demonstrate that the atomic constituents of the electrode/electrolyte engage in significant dynamic motion. We report the stability of the sodium beta“-alumina phase in low pressure sodium vapor at 1173K up to 3000 hours, and the decomposition of the sodium meta-aluminate (NaAlO2) phase present at about 1% in the BASE ceramic, which gives rise to transient local increases in the solid electrolyte resistivity due to local micro-cracking. We also report slow apparent morphological changes, possibly surface or grain boundary reconstruction, in TiN and RhW electrodes driven by changes in the local sodium activity.
X