Refine Your Search

Search Results

Technical Paper

MIMO Control of a Turbogenerator for Energy Recovery

2020-04-14
2020-01-0261
Market trends for increased engine power and more electrical energy on the powergrid (3kW+), along with customer demands for fuel consumption improvements and emissions reduction, are driving requirements for component electrification, including turbochargers. GTDI engines waste significant exhaust enthalpy; even at moderate loads the WG (Wastegate) starts to open to regulate the turbine power. This action is required to reduce EBP (Exhaust Back Pressure). Another factor is catalyst protection, where the emissions device is placed downstream turbine. Lambda enrichment or over-fueling is used to perform this. However, the turbine has a temperature drop across it when used for energy recovery. Since catalyst performance is critical for emissions, the only reasonable location for an additional device is downstream of it. This is a challenge for any additional energy recovery, but a smaller turbine is a design requirement, optimized to operate at lower pressure ratios.
X