Technical Paper
The Development and Testing of a Volatile Organics Concentrator for Use in Monitoring Space Station Water Quality
1992-07-01
921266
An approach to the isolation and concentration of volatile organic compounds from a water sample prior to chemical analysis in a microgravity environment has been previously described (Reference 1). The Volatile Organics Concentrator (VOC) system was designed to attach to a gas chromatograph/mass spectrometer (GC/MS) for analysis of volatile organic compounds in water on Space Station Freedom. The VOC utilizes a primary solid sorbent for collection and concentration of the volatile compounds, transfer of the volatiles through a permeation dryer to a secondary solid sorbent, followed by thermal desorption of volatiles from the secondary sorbent onto a GC/MS system. Fabrications and preliminary testing of the VOC breadboard using a gas chromatography equipped with flame ionization detector has been previously described (Reference 2). These results have indicated that the VOC will meet or exceed the goals set for the program.