Technical Paper

Characterization of High-Tumble Flow Effects on Early Injection for a Lean-Burn Gasoline Engine

2023-04-11
2023-01-0238
The influence of early induction stroke direct injection on late-cycle flows was investigated for a lean-burn, high-tumble, gasoline engine. The engine features side-mounted injection and was operated at a moderate load (8.5 bar brake mean effective pressure) and engine speed (2000 revolutions per minute) condition representative of a significant portion of the duty cycle for a hybridized powertrain system. Thermodynamic engine tests were used to evaluate cam phasing, injection schedule, and ignition timing such that an optimal balance of acceptable fuel economy, combustion stability, and engine-out nitrogen oxide (NOx) emissions was achieved. A single cylinder of the 4-cylinder thermodynamic engine was outfitted with an endoscope that enabled direct imaging of the spark discharge and early flame development.
Journal Article

Gasoline Direct Injector Deposits: Impacts of Fouling Mechanism on Composition and Performance

2022-03-29
2022-01-0488
Injector performance in gasoline Direct-Injection Spark-Ignition (DISI) engines is a key focus in the automotive industry as the vehicle parc transitions from Port Fuel Injected (PFI) to DISI engine technology. DISI injector deposits, which may impact the fuel delivery process in the engine, sometimes accumulate over longer time periods and greater vehicle mileages than traditional combustion chamber deposits (CCD). These higher mileages and longer timeframes make the evaluation of these deposits in a laboratory setting more challenging due to the extended test durations necessary to achieve representative in-use levels of fouling. The need to generate injector tip deposits for research purposes begs the questions, can an artificial fouling agent to speed deposit accumulation be used, and does this result in deposits similar to those formed naturally by market fuels?
Technical Paper

Ignition and Soot Formation/Oxidation Characteristics of Compositionally Unique International Diesel Blends

2019-04-02
2019-01-0548
With the global adoption of diesel common rail systems and the wide variation in composition of local commercial fuels, modern fuel injection systems must be robust against diverse fuel properties. To bridge the knowledge gap on the effects of compositional variation for real commercial fuels on spray combustion characteristics, the present work quantifies ignition and soot formation/oxidation in three unique, international diesel blends. Schlieren imaging, excited-state hydroxyl radical (OH*) chemiluminescence imaging and diffused back-illumination extinction imaging were employed to quantify vapor penetration, ignition, and soot formation and oxidation for high-pressure sprays in a constant-volume, pre-burn chamber. The three fuels were procured from Finland, Japan and Brazil and have cetane numbers of 64.1, 56.1 and 45.4, respectively.
Journal Article

Effects of Oxygenated Fuels on Combustion and Soot Formation/Oxidation Processes

2014-10-13
2014-01-2657
The Leaner Lifted-Flame Combustion (LLFC) strategy offers a possible alternative to low temperature combustion or other globally lean, premixed operation strategies to reduce soot directly in the flame, while maintaining mixing-controlled combustion. Adjustments to fuel properties, especially fuel oxygenation, have been reported to have potentially beneficial effects for LLFC applications. Six fuels were selected or blended based on cetane number, oxygen content, molecular structure, and the presence of an aromatic hydrocarbon. The experiments compared different fuel blends made of n-hexadecane, n-dodecane, methyl decanoate, tri-propylene glycol monomethyl ether (TPGME), as well as m-xylene. Several optical diagnostics have been used simultaneously to monitor the ignition, combustion and soot formation/oxidation processes from spray flames in a constant-volume combustion vessel.
Journal Article

Transmission Electron Microscopy of Soot Particles Directly Sampled in Diesel Spray Flame - A Comparison between US#2 and Biodiesel Soot

2012-04-16
2012-01-0695
For a better understanding of soot formation and oxidation processes in conventional diesel and biodiesel spray flames, the morphology, microstructure and sizes of soot particles directly sampled in spray flames fuelled with US#2 diesel and soy-methyl ester were investigated using transmission electron microscopy (TEM). The soot samples were taken at 50mm from the injector nozzle, which corresponds to the peak soot location in the spray flames. The spray flames were generated in a constant-volume combustion chamber under a diesel-like high pressure and high temperature condition (6.7MPa, 1000K). Direct sampling permits a more direct assessment of soot as it is formed and oxidized in the flame, as opposed to exhaust PM measurements. Density of sampled soot particles, diameter of primary particles, size (gyration radius) and compactness (fractal dimension) of soot aggregates were analyzed and compared. No analysis of the soot micro-structure was made.
Technical Paper

Flame Lift-Off on Direct-Injection Diesel Fuel Jets: Oxygen Concentration Effects

2002-03-04
2002-01-0890
The effects of reductions in the ambient gas oxygen concentration on the flame lift-off length on direct-injection (DI) diesel fuel jets under quiescent conditions were experimentally investigated. Reductions in the ambient (i.e., in-cylinder) gas oxygen concentration occur in an engine when exhaust gas recirculation is used to reduce the emission of nitrogen oxides. Also examined were the effects of the changes in lift-off length observed for various conditions on the total amount of oxygen entrained upstream of the lift-off location, soot formation, and the relationship between fuel vaporization and combustion processes. The research was conducted in a constant-volume combustion vessel using a common-rail fuel injector and a Phillips research grade #2 diesel fuel. The lift-off length measurements show that lift-off length is inversely proportional to the ambient gas oxygen concentration.