Refine Your Search

Topic

Search Results

Standard

Closed-Cycle Protective Breathing Devices

2023-01-26
CURRENT
AIR825/11A
Closed-cycle protective breathing apparatus, commonly referred to as rebreathers, or CCBA provide trained aircrew members or ground personnel with eye and respiratory protection from toxic atmospheres.
Standard

Packaging and Transportation of Oxygen Equipment

2023-01-26
CURRENT
AIR5742A
The scope of this document is related to the particular needs of oxygen equipment with regards to packaging and transportation. The document provides guidance for handling chemical, gaseous and liquid oxygen equipment. It summarizes national and international regulations to be taken into account for transportation on land, sea and air and provides information on classification of hazardous material. The aim of this document is to summarize information on packaging and transportation of oxygen equipment. Statements and references to regulations cited herein are for information only and should not be considered as interpretation of a law. Processes to maintain cleanliness of components and subassemblies during processing and assembly or storage of work-in-progress are outside the scope of this document. Guidance on this can be obtained from ARP1176.
Standard

Testing of Oxygen Equipment

2021-08-11
CURRENT
ARP1398A
This ARP delineates requirements for system cleanliness, test gas supply system, test stand design, environmental chamber definition, instrumentation, dynamic test equipment and testing procedures.
Standard

Chemical Oxygen Systems

2021-08-09
CURRENT
AIR825/4A
This SAE Aerospace Information Report (AIR) provides an orientation regarding the general technology of chemical oxygen generators to aircraft engineers for assistance in determining whether chemical oxygen generators are an appropriate oxygen supply source for hypoxia protection in a given application and as an aid in specifying such generators. Information regarding the details of design and manufacture of chemical oxygen generators is generally beyond the scope of this document.
Standard

Lubricants for Oxygen Use

2020-07-14
CURRENT
AIR4071A
This SAE Aerospace Information Report (AIR) describes two classes of lubricants which, when properly applied, can be used in oxygen systems and components.
Standard

Passenger Hypoxia Protection Utilizing Oxygen Enriched Gas Mixtures

2018-10-18
CURRENT
AIR6036
Currently, existing civil aviation standards address the design and certification of oxygen dispensing devices that utilize oxygen sources supplying at least 99.5% oxygen. This Aerospace Information Report discusses issues relating to the use in the passenger cabin of oxygen enriched breathing gas mixtures having an oxygen content of less than 99.5% and describes one method of showing that passenger oxygen dispensing devices provide suitable hypoxia protection when used with such mixtures.
Standard

Oxygen Flow Indicators

2016-06-09
HISTORICAL
AS916B
This SAE Aerospace Standard (AS) defines the overall requirements applicable to oxygen flow indicating devices intended to operate in conjunction with an oxygen regulator and mask system. Flow indicators covered by this document are for use with pressure demand, diluter-demand and continuous flow oxygen systems.
Standard

Chemical Oxygen Supplies

2014-10-30
CURRENT
AIR1133B
Solid chemical oxygen supplies of interest to aircraft operations are "chlorate candles" and potassium superoxide (KO2). Chlorate candles are used in passenger oxygen supply units and other emergency oxygen systems, such as submarines and escape devices. Potassium superoxide is not used in aircraft operations but is used in closed-cycle breathing apparatus. Characteristics and applications of both are discussed, with emphasis on chlorate candles.
Standard

Oxygen Systems for General Aviation

2014-07-11
CURRENT
AIR822C
This SAE Aerospace Information Report (AIR) provides a general overview of oxygen systems for general aviation use. Included are a brief review of the factors and effects of hypoxia, system descriptions, and mission explanations for system or component selection, and techniques for safe handling of oxygen distribution systems.
Standard

Aviator's Breathing Oxygen Purity Standard

2012-10-18
HISTORICAL
AS8010C
This document defines the minimum degree of purity and maximum levels of certain deleterious impurities allowable for aviator's breathing oxygen at the point of manufacture or generation. It covers gaseous, liquid, and chemically generated oxygen, and oxygen supplied by in situ concentration and in situ electrolysis. Different limits are established for oxygen from different sources, in recognition of differences in the ways the oxygen is stored, dispensed, and utilized, taking into account the safety of the user. These limits are not intended to specifically reflect upon the relative capabilities or merits of various technologies. Procurement documents may specify more stringent limits, where required for specific applications. Medical oxygen is not covered by this standard. In the United States, medical oxygen is a prescription drug.
Standard

Determination of Chlorine in Oxygen from Solid Chemical Oxygen Generators

2012-10-15
CURRENT
ARP1320B
This ARP covers a procedure to be used in the determination of 0.05 to 0.3 ppm of chlorine in oxygen from any type of generator used for emergency or other life-support systems. The methyl orange method described can be considered as a referee technique. Instrumental analysis is also given in Section 8.
Standard

Chemical Oxygen Supplies

2012-10-08
HISTORICAL
AIR1133A
Solid chemical oxygen supplies of interest to aircraft operations are "chlorate candles" and potassium superoxide (KO2). Chlorate candles are used in passenger oxygen supply units and other emergency oxygen systems, such as submarines and escape devices. Potassium superoxide is not used in aircraft operations but is used in closed-cycle breathing apparatus. Characteristics and applications of both are discussed, with emphasis on chlorate candles.
Standard

Glossary of Technical and Physiological Terms Related to Aerospace Oxygen Systems

2012-10-08
HISTORICAL
AIR171D
The scope of this document is to provide a list of specialized terms with their meanings. The glossary will assist the use of other documents related to aircraft oxygen equipment by defining ubiquitous terminology in context of this specialized field. The glossary contains terms of primary importance in the areas of chemistry, equipment, and physiology.
Standard

Automatic Presentation of Supplemental Oxygen Masks

2012-04-12
HISTORICAL
ARP4287
This SAE Aerospace Recommended Practice (ARP) provides design, operation, construction, test and installation recommendations for equipment that automatically presents supplemental oxygen masks to cabin occupants in the event of loss of cabin pressure. It specifically covers automatic presentation for transport category aircraft that operate above 30,000 ft (9144 m) altitude, although it also provides guidance for similar equipment used in non-transport category aircraft, or aircraft operated below 30,000 f (9144 m) altitude.
Standard

CONTINUOUS FLOW CHEMICAL OXYGEN GENERATORS

2011-08-15
HISTORICAL
AS1304
This Aerospace Standard (AS) provides recommended design guidelines for composition formation, performance, testing and reliability of metal-chlorate-perchlorate class solid chemical oxygen generators, supplying oxygen at essentially ambient pressure, for aircraft whose cabin pressure altitude does not exceed 40,000 feet (12,192 m).
Standard

Determination of Chlorine in Oxygen from Solid Chemical Oxygen Generators

2011-06-21
HISTORICAL
ARP1320A
This ARP covers a procedure to be used in the determination of 0.05 to 0.3 ppm of chlorine in oxygen from any type of generator used for emergency or other life-support systems. The methyl orange method described can be considered as a referee technique. Instrumental analysis is also given in Section 8.
Standard

Lubricants for Oxygen Use

2007-12-05
HISTORICAL
AIR4071
This SAE Aerospace Information Report (AIR) describes two classes of lubricants which, when properly applied, can be used in oxygen systems and components.