Refine Your Search

Topic

Search Results

Standard

Aircraft Evacuation Signal System

2022-08-05
CURRENT
ARP1178C
This SAE Aerospace Recommended Practice recommends general criteria for the development and installation of an aircraft emergency signal system to permit any crew member (flight or cabin) to inform all other crew members that an emergency evacuation situation exists and that an evacuation has been or should be immediately started.
Standard

Emergency, Instruction, and Information Placards - Internal and External

2022-08-05
CURRENT
ARP577F
This SAE Aerospace Recommended Practice (ARP) specifies criteria for the design, development, standardization, and comprehension testing of placards containing pictures, drawings, symbols, and/or written instructions for locating and operating aircraft emergency equipment. This ARP also provides guidance in the selection and implementation of warning placards intended to instruct occupants inside, and rescue personnel outside, the aircraft.
Standard

Issues in Stairway Design Aboard Transport Category Airplanes

2022-03-21
CURRENT
AIR5670A
This document contains information that can be used by the air transportation industry to evaluate the design of airplane interior stairways with respect to the safety of passengers and crew in normal operating conditions and emergency evacuations.
Standard

Comprehensibility Testing for Pictogram-Based Aircraft Signs and Placards

2020-04-27
CURRENT
ARP8996
This SAE Aerospace Recommended Practice (ARP) applies to comprehensibility testing of aircraft markings, signs, and placards that are intended to provide information to passengers, crew, or ground personnel exclusively through pictorial symbols (pictograms). Markings, signs, and placards where text is complemented by pictograms are not in the scope of this document. In case text and pictograms are used in a redundant manner, comprehension testing is not required.
Standard

Issues in Stairway Design Aboard Transport Category Airplanes

2016-10-22
HISTORICAL
AIR5670
This document contains information that can be used by the air transportation industry to evaluate the design of airplane interior stairways with respect to the safety of passengers and crew in normal operating conditions and emergency evacuations.
Standard

Safety Briefings for Passengers in Exit Rows

2014-05-02
HISTORICAL
ARP5655
This SAE ARP provides guidance for (1) ensuring passenger suitability for being seated in an exit row and (2) the standardization of safety briefings for passengers, seated at exits, who may be responsible for opening exits on transport airplanes during an emergency. This recommendation is primarily for briefing passengers seated in the Type III overwing exit row, but may be applied to briefing passengers responsible for other exit types. In addition, these recommendations pertain to briefings on airplanes on which the flight attendants would conduct the exit row briefing, and to briefings on airplanes without flight attendants, on which pilots would conduct the briefing.
Standard

Cabin Stowage of Personal Wheelchairs

2013-04-20
CURRENT
AIR4496A
This SAE Aerospace Information Report (AIR) provides guidance criteria for the storage of personal wheelchairs in the passenger compartment of transport category aircraft, which have not been provided by the air carrier and are designated for the sole use of the passenger requiring such assistance.
Standard

Cabin Stowage of Personal Wheelchairs

2006-11-03
HISTORICAL
AIR4496
This SAE Aerospace Information Report (AIR) provides guidance criteria for the storage of personal wheelchairs in the passenger compartment of transport category aircraft, which have not been provided by the air carrier and are designated for the sole use of the passenger requiring such assistance.
Standard

Lavatory Smoke Detectors

2006-02-17
HISTORICAL
ARP4001A
The purpose of this SAE Aerospace Recommended Practice (ARP) is to describe key features that should be incorporated in the lavatory smoke detector system. Consideration has been given to existing requirements of the FAA and to recommendations of aircraft operators and manufacturers. This document is deliberately not specific in all areas in order to maximize the freedom to use state-of-the-art design and manufacturing technologies. Safe, reliable, and effective lavatory smoke detectors remain the primary goal of the document.
Standard

Standard Galley System Specification Part I, Performance, Design, Development

2005-08-31
HISTORICAL
AS1426A
This specification (Part I) covers the performance, design, development and test requirements for the standard galley system. The galley equipment comprising the standard system includes standard containers, carts (trolleys), modules, ovens, refrigerators, coffee makers, water boilers, hot jugs, and related items; and several standard configurations and sizes of galley shell structures with internal arrangement options. Standard tray and entree dish envelopes are also defined, allowing variations for user styling and shape within related equipment space provisions.
Standard

Aircraft Evacuation Signal System

1998-06-01
HISTORICAL
ARP1178A
This SAE Aerospace Recommended Practice (ARP) establishes the criteria for the development and installation of an aircraft emergency signal system to permit any crew member to inform all other crew members that an emergency evacuation situation exists and that an evacuation has been or should be immediately started.
X