Refine Your Search

Search Results

Viewing 1 to 6 of 6
Journal Article

Meeting Nonroad Final Tier 4 Emissions on a 4045 John Deere Engine Using A Fuel Reformer and LNT System with An Optional SCR Showing Transparent Vehicle Operation, Vehicle Packaging and Compliance to End-of-Life Emissions

2011-09-13
2011-01-2206
The nonroad Final Tier 4 US EPA emission standards require 88% reduction in NOx emission from the Interim Tier 4 standards. It is necessary to utilize aftertreatment technologies to achieve the required NOx reduction. The development of a fuel reformer, lean NOx trap (LNT) and optional selective catalytic reactor (SCR) on a John Deere 4045 nonroad engine is described in this paper. The paper discusses aftertreatment system performance, catalyst formulations and system controls of a fuel vaporizer, fuel reformer, LNT and SCR system designed to meet the nonroad Final Tier 4 emission standards. The 4045 John Deere engine was calibrated and integrated with the aftertreatment system. The system performance was characterized in an engine dynamometer performance test cell, durability test cell and on a vehicle. The catalyst performance was evaluated using aged catalysts and a detailed description of the LNT, DPF and SCR catalysts is provided.
Technical Paper

Final Tier 4 Emission Solution Using An Aftertreatment System With A Fuel Reformer, LNT, DPF And Optional SCR

2011-09-13
2011-01-2197
Diesel exhaust aftertreatment systems are required for meeting Final Tier 4 emission regulations. This paper addresses an aftertreatment system designed to meet the Final Tier 4 emission standards for nonroad vehicle markets. The aftertreatment system consists of a fuel dosing system, mixing elements, fuel vaporizer, fuel reformer, lean NOx trap (LNT), diesel particulate filter (DPF), and an optional selective catalytic reduction (SCR) catalyst. Aftertreatment system performance, both with and without the SCR, was characterized in an engine dynamometer test cell, using a 4.5 liter, pre-production diesel engine. The engine out NOx nominally ranged between 1.6 and 2.0 g/kW-hr while all operating modes ranged between 1.2 and 2.8 g/kW-hr. The engine out particulate matter was calibrated to approximately 0.1 g/kW-hr for various power ratings. Three engine power ratings of 104 kW, 85 kW and 78 kW were evaluated.
Technical Paper

Time-Resolved and Quantitative Characterization of Highly Transient Gasoline Sprays by X-Radiography

2002-06-03
2002-01-1893
Using synchrotron x-radiography and mass deconvolution techniques, this work reveals strikingly interesting structural and dynamic characteristics of the direct injection (DI) gasoline hollow-cone sprays in the near-nozzle region. Employed to measure the sprays, x-radiography allows quantitative determination of the fuel distribution in this optically impenetrable region with a time resolution of better than 1 μs, revealing the most detailed near-nozzle mass distribution of a DI gasoline fuel spray ever detected. Based on the x-radiographs of the spray collected from four different perspectives, enhanced mathematical and numerical analyses were developed to deconvolute the mass density of the gasoline hollow-cone spray. This leads to efficient and accurate regression curve fitting of the measured experimental data to obtain essential parameters of the density distribution that are then used in reconstructing the cross-sectional density distribution at various times and locations.
Technical Paper

Shock Waves Generated by High-Pressure Fuel Sprays Directly Imaged by X-Radiography

2002-06-03
2002-01-1892
Synchrotron x-radiography and a novel fast x-ray detector are used to visualize the detailed, time-resolved structure of the fluid jets generated by a high pressure diesel-fuel injection. An understanding of the structure of the high-pressure spray is important in optimizing the injection process to increase fuel efficiency and reduce pollutants. It is shown that x-radiography can provide a quantitative measure of the mass distribution of the fuel. Such analysis has been impossible with optical imaging due to the multiple-scattering of visible light by small atomized fuel droplets surrounding the jet. In addition, direct visualization of the jet-induced shock wave proves that the fuel jets become supersonic under appropriate injection conditions. The radiographic images also allow quantitative analysis of the thermodynamic properties of the shock wave.
Technical Paper

X-Ray Measurements of High Pressure Diesel Sprays

2001-03-05
2001-01-0531
A quantitative and time-resolved technique has been developed to probe the fuel distribution very near the nozzle of a high-pressure diesel injector. This technique uses the absorption of synchrotron x-rays to measure the fuel mass with good time and position resolution. The penetrating power of x-rays allows measurements that are difficult with other techniques, such as quantitative measurements of the mass and penetration measurements of the trailing edge of the spray. Line-of-sight measurements were used to determine the fuel density as a function of time. The high time resolution and quantitative nature of the measurement also permit an accurate measure of the instantaneous mass flow rate through the nozzle.
Technical Paper

Quantitative Measurements of Direct-Injection Gasoline Fuel Sprays in Near-Nozzle Region Using Synchrotron X-Ray

2001-03-05
2001-01-1293
A quantitative and time-resolved technique has been developed to probe the dense spray structure of direct-injection (DI) gasoline sprays in near-nozzle region. This technique uses the line-of-sight absorption of monochromatic x-rays from a synchrotron source to measure the fuel mass with time resolution better than 1 μs. The small scattering cross-section of fuel at x-rays regime allows direct measurements of spray structure that are difficult with most visible-light optical techniques. Appropriate models were developed to determine the fuel density as a function of time.
X