Standard

Procedure for Certification that Requirements for Mobile Air Conditioning System Components, Service Equipment, and Service Technician Training Meet SAE J Standards

2013-01-14
J2911_201301
This SAE Standard provides manufacturers, testing facilities and providers of technician training with a procedure for certifying compliance with the appropriate standards. Manufacturers or seller who advertise their products as Certified to an SAE J standard shall follow this procedure. Certification of a product is voluntary; however, this certification process is mandatory for those advertising meeting SAE Standard(s) requirements. Only certifying to this standard allows those claiming compliance to advertise that their product (unit), component, or service meets all requirements of the specific SAE standard. Certification of compliance to this and the appropriate standard and use of the SAE label on the product shall only be permitted after all the required information has been submitted to SAE International and it has been posted on the SAE web site.
Standard

Procedure for Certification that Requirements for Mobile Air Conditioning System Components, Service Equipment, and Service Technician Training Meet SAE J Standards

2012-01-12
J2911_201201
This SAE Standard provides manufacturers, testing facilities and providers of technician training with a procedure for certifying compliance with the appropriate standards. Manufacturers who advertise their products as Certified to an SAE J standard shall follow this procedure. Certification of a product is voluntary, however, this certification process is mandatory for those advertising meeting SAE Standard(s) requirements. Only certifying to this standard allows those claiming compliance to advertise that their product (unit), component, or service meets all requirements of the specific SAE standard. Certification of compliance to this and the appropriate standard and use of the SAE label on the product shall only be permitted after all the required information has been submitted to SAE International and it has been posted on the SAE web site.
Standard

Procedure for Certification that Requirements for Mobile Air Conditioning System Components, Service Equipment, and Service Technician Training Meet SAE J Standards

2011-02-04
J2911_201102
This SAE Standard provides manufacturers, testing facilities and providers of technician training with a procedure for certifying compliance with the appropriate standards. Manufacturers who advertise their products as Certified to an SAE J standard shall follow this procedure. Certification of a product is voluntary, however, this certification process is mandatory for those advertising meeting SAE Standard(s) requirements. Only certifying to this standard allows those claiming compliance to advertise that their product (unit), component, or service meets all requirements of the specific SAE standard. Certification of compliance to this and the appropriate standard and use of the SAE label on the product shall only be permitted after all the required information has been submitted to SAE International and it has been posted on the SAE web site.
Standard

Safety Standards for Motor Vehicle Refrigerant Vapor Compression Systems

2011-02-04
J639_201102
This SAE Standard applies to refrigerant vapor compression systems that provide cooling and/or heating for passenger cars, light trucks and commercial vehicles (on and off road) that use automotive type mobile air conditioning (MAC) systems. Large trucks, buses and other vehicles that do not use typical automotive a/c systems or use refrigerants not listed in this document are not covered by this standard. This standard covers any vehicle with a MAC system using a belt or electric motor driven compressor. This document provides standards for design, assembly, test and service of MAC systems to minimize environmental, health and safety impacts. Also included are cautionary statements for the service industry to alert technicians to the inadvisability and possible health or safety effects associated with venting refrigerant during service. It is not intended to restrict the use, or further development, of other types of refrigeration systems for mobile air conditioning applications.
Standard

HFC-134a Refrigerant Electronic Leak Detectors, Minimum Performance Criteria

2008-09-25
J2791_200809
This SAE Standard provides testing and functional requirements to meet specified minimum performance criteria for electronic probe-type leak detectors. So they will identify smaller refrigerant leaks when servicing all motor vehicle air conditioning systems, including those engineered with improved sealing and smaller refrigerant charges to address environmental concerns and increase system efficiency. This document does not address any safety issues concerning their design or use.
Standard

HFC-134a Mobile Air Conditioning System Emission Chart

2007-07-12
J2727_200707
The original SAE J2727 “Leakage Chart” provided a rating system for comparing mobile A/C systems and was not intended to define mobile A/C system refrigerant leakage. It had been developed from industry experience of expected system refrigerant leakage based upon currently available technologies. The new “System Emissions Chart” now contained in this revision is intended to serve as a means of estimating the annual refrigerant emissions rate (grams per year) from new production A/C systems equipped with specified component technologies. It provides emission values for various component technologies that are currently available, and can be expanded as new technologies are commercialized. This document provides the information to develop an Excel file template “System Emissions Chart” for system emission analysis. The new chart includes automotive compressor technologies, for conventional mobile air conditioning systems as well as fully hermetic compressors.
Standard

HFC-134a Refrigerant Electronic Leak Detectors, Minimum Performance Criteria

2007-01-12
J2791_200701
This SAE Standard applies to electronic probe-type leak detectors used to identify refrigerant leakage when servicing motor vehicle air conditioning systems. This document does not address any safety issues concerning their design or use. The purpose of this SAE Standard is to establish the minimum performance criteria for electronic probe-type leak detectors.
Standard

R134a Refrigerant Automotive Air-Conditioned Hose

2005-12-12
J2064_200512
This SAE Standard covers hose and hose assemblies intended for conducting liquid and gaseous R134a refrigerant in automotive air-conditioning systems. The hose shall be designed to minimize permeation of R134a refrigerant, contamination of the system, and to be functional over a temperature range of –30 °C to 125 °C. Specific construction details are to be agreed upon between user and supplier. A hose marked “J2064” signifies that it has been coupled, tested, and has met the requirements of SAE J2064. It is the hose assembly manufacturer’s responsibility to see that the assemblies meet the specified acceptance criteria for this specification.
Standard

Safety Standards for Motor Vehicle Refrigerant Vapor Compresssions Systems

2005-06-20
J639_200506
This SAE Standard Practice is restricted to refrigerant vapor compression systems that provide cooling and/or heating for the passenger compartment. This document provides design standards for refrigerant containment and safety for these systems. Also included are cautionary statements for the mobile air conditioning service industry to alert service technicians to the inadvisability and the possible health and safety effects associated with venting refrigerant during service. It is not intended to restrict the use, or further development, of other types of refrigeration systems for passenger compartment cooling. Should other systems be found practical, this document may be amended or an additional standard safety practice created for such systems. This document addresses only CFC-12 (R-12), HFC-134a (R-134a), HFC152a (R-152a) a flammable gas and carbon dioxide (R-744) refrigerants.
Standard

R134a Mobile Air Conditioning System Leakage Chart

2005-06-08
J2727_200506
Current industry standards do not exist for determining refrigerant emissions from mobile air conditioning systems. Test procedures are not common between production component suppliers in establishing leakage values. This “System Leakage Chart” has been developed from industry experience of expected refrigerant leakage gains from system design resulting from technology changes. It provides a rating value of various technologies that are currently available. The “Leakage Chart” can be expanded as new technologies are offered and/or developed. This document provides the information to develop an Excel file template “Leakage Chart” for making system analysis. It is not the intent of this Standard to define the refrigerant emissions from a mobile air conditioning system. It is to only define a system rating based upon the technology used.
Standard

Passenger Car Windshield Defrosting Systems

2003-07-09
J902_200307
This SAE Recommended Practice provides a test procedure and performance guideline for evaluating passenger vehicle windshield defrosting systems. It is limited to results of tests that can be conducted on uniform test equipment in commercially available laboratory facilities. The current engineering practice prescribes that for laboratory evaluation of defroster systems, a known quantity of water shall be sprayed on the windshield to form an ice coating and then melted by the defroster under specific vehicle operating conditions. The procedure provides uniform and repeatable laboratory test results, even though under actual conditions such a coating would be removed by scraping before driving the vehicle. The performance obtained, therefore, does not directly relate to actual driving conditions, but serves as a laboratory performance indicator for comparing test results within or between systems.
Standard

R134a Refrigerant Automotive Air-Conditioning Hose

1999-06-24
J2064_199906
This SAE Standard covers hose and hose assemblies intended for conducting liquid and gaseous R134a refrigerant in automotive air-conditioning systems. The hose shall be designed to minimize permeation of R134a refrigerant, contamination of the system, and to be functional over a temperature range of –30 to 125 °C. Specific construction details are to be agreed upon between user and supplier. A hose marked “J2064” signifies that it has been coupled, tested, and has met the requirements of SAE J2064. It is the hose assembly manufacturer’s responsibility to see that the assemblies meet the specified acceptance criteria for this specification.
Standard

Recovery and Recycle Equipment for Mobile Automotive Air-Conditioning Systems

1999-02-01
J1990_199902
The purpose of this SAE Standard is to provide equipment specifications for CFC-12 (R-12) recycling equipment. This information applies to equipment used to service automobiles, light trucks, and other vehicles with similar CFC-12 (R-12) air-conditioning (A/C) systems. Systems used on mobile vehicles for refrigerating cargo that have hermetically sealed systems are not covered in this document. The equipment in this document is intended for use with refrigerant that has been directly removed from, and intended to be returned to, a mobile A/C system. Should other revisions due to operational or technical requirements occur, this document may be amended.
Standard

Motor Vehicle Heater Test Procedure

1998-11-05
J638_199811
This SAE Recommended Practice, limited to liquid coolant systems, establishes uniform vehicle heater test procedures. Both laboratory and complete vehicle tests are specified in this document. Required test equipment, facilities, and definitions are included.
Standard

R134a Refrigerant Automotive Air-Conditioning Hose

1998-08-01
J2064_199808
This SAE Standard covers hose and hose assemblies intended for conducting liquid and gaseous R134a refrigerant in automotive air-conditioning systems. The hose shall be designed to minimize permeation of R134a refrigerant, contamination of the system, and to be functional over a temperature range of −30 to 125 °C. Specific construction details are to be agreed upon between user and supplier. A hose marked “J2064” signifies that it has been coupled, tested, and has met the requirements of SAE J2064. It is the hose assembly manufacturer’s responsibility to see that the assemblies meet the specified acceptance criteria for this specification.
Standard

SERVICE HOSE FOR AUTOMOTIVE AIR CONDITIONING

1997-03-01
J2196_199703
This SAE Standard covers reinforced rubber, reinforced thermoplastic, or otherwise constructed hose, or hose assemblies, intended for conducting liquid and gaseous refrigerants for service connections from mobile air conditioning systems to service equipment such as a manifold gauge set and vacuum pumps or for use internally, in charging stations or service equipment intended for use in servicing mobile air-conditioning systems.
Standard

PERFORMANCE CRITERIA FOR ELECTRONIC REFRIGERANT LEAK DETECTORS

1995-08-01
J1627_199508
This SAE Standard applies to electronic probe-type leak detectors used to service motor vehicle passenger compartment air-conditioning systems. This document does not address any safety issues concerning their design or use.